JHJia-Jun Hu

Jia-Jun Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years

Research Subjects

Research Interests


Jia-Jun Hu has a total of 1 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multirow Film-Cooling Effectiveness of Vertically Oriented Slot Cross-Section Diffusion Holes on a Turbine Nozzle Guide Vane Suction Surface

    by Jia-Jun Hu, Bai-Tao An

    In this article, a multirow film-cooling effectiveness experiment was conducted on a turbine nozzle guide vane suction surface using the pressure-sensitive paint (PSP) measurement technique. Five rows of film holes were designed at the suction side with a streamwise staggered arrangement and a 6D spanwise hole spacing. Two diffusion holes constructed based on a vertically oriented slot cross-section with 14-deg and 20-deg exit expansion angles were tested. A fan-shaped hole and a horizontally oriented slot cross-section diffusion hole were chosen as the baselines, and both had a 14-deg exit expansion angle. The experiment was carried out in a linear cascade with a mainstream Reynolds number of 62000, a mainstream turbulence intensity of 3.7%, and a coolant-to-mainstream density ratio of 1.5. The four averaged blowing ratios ranged from 0.5 to 2.0. The results showed that, regardless of the blowing ratio, under intense multirow film interactions, the vertically oriented slot cross-section diffusion holes can always produce uniform and consistent film coverage on the vane suction surface. The vertically oriented slot cross-section widens the distance between the up- and downstream walls and narrows the lateral width, thereby weakening the influence of the entrance “jetting effect.” The resulting flow pattern can adapt to a larger exit expansion angle. In addition to the smaller difference under a low blowing ratio, two vertically oriented slot cross-section diffusion holes yield prominently greater multirow effectiveness than do the horizontally oriented slot cross-section diffusion hole and conventional fan-shaped hole, in which the case with a 20-deg expansion angle performs better.


  • Effects of Ribbed Crossflow Channel in a Turbine Blade on Film Cooling Performance of Diffusion Slot Holes with Various Cross Section Orientations

    by Jia-Jun Hu, Bai-Tao An

    This paper investigates the influence of ribbed crossflow on the film cooling performance of a turbine rotor blade. A pressure-sensitive paint measurement technique was employed to measure the effectiveness of film cooling. The discharge coefficients were also measured to determine the flow resistance. A row of film holes was positioned at the pressure surface or suction surface with a spanwise hole spacing of 7.5D, which is half of the rib spacing. The experiments were carried out at a mainstream Reynolds number of 520,000, a turbulence intensity of 3.6%, and a density ratio of 0.97. The crossflow inlet velocity was 45% of the cascade inlet velocity. A fan-shaped hole with a 14 deg expansion angle (Fans-14), a horizontally oriented slot cross section diffusion hole with a 14 deg expansion angle (H1.7-14), and two vertically oriented slot cross section diffusion holes with 14 deg (V1.7-14) and 20 deg (V1.7-20) expansion angles were tested with/without crossflow. The results indicated that the slot cross-sectional orientation significantly changes the flow patterns inside the holes. H1.7-14 has stronger lateral expansion and better surface adhesion, while V1.7-14 and V1.7-20 yield more uniform lateral velocity distributions. Regardless of crossflow, H1.7-14 produces the highest film effectiveness and discharge coefficient on the pressure surface, while it changes to V1.7-20 on the suction surface. The ribbed crossflow increases the film effectiveness on both the pressure surface and suction surface, except for V1.7-20, as it is almost unaffected by the crossflow.


  • Film Cooling Effectiveness on Pressure Surface and Suction Surface of Turbine Guide Vane With Diffusion Slot Holes

    by Jia-Jun Hu, Bai-Tao An

    This paper investigated the film-cooling effectiveness of diffusion slot holes in a turbine nozzle guide vane. The pressure-sensitive paint measurement technique was employed to obtain the film-cooling effectiveness at a density ratio of DR = 1.5. The mainstream Reynolds number based on the axial chord length and the exit velocity was 6 × 105. The mainstream turbulence intensity was approximately 3.7%. Three diffusion slot hole geometries with cross-sectional aspect ratios (ASs) of 2.3, 3.4, and 4.9 were tested and compared with a typical fan-shaped hole. The experiments were performed at three typical hole row locations on the pressure surface (PS) and suction surface (SS). The average blowing ratios varied from M = 0.5 to 2.5. The results showed that throughout the blowing ratio range, on the PS, a substantially higher film-cooling effectiveness than the fan-shaped hole is always obtained from the diffusion slot hole with a large aspect ratio (AS = 4.9); on the SS, the diffusion slot hole with a small AS (AS = 2.3). The influence of hole row positioning is inconsistent for diffusion slot holes with different ASs. The diffusion slot hole is less affected by the PS when the AS is moderate and less affected by the SS when the AS is large. The film-cooling effectiveness of the diffusion slot holes is basically the lowest where the PS has a maximum concave curvature and the highest where the SS has a large favorable pressure gradient.