Anna Multhaup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anna Multhaup has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Charlotte Lößner
Department of Gynecology, University Hospital Jena, Friedrich-Schiller-University Jena, Am Klinikum 1, 07747 Jena, Germany
1 shared publication - Ekkehard Schleußner
Department of Obstetrics, University Hospital Jena, Friedrich Schiller University, Am Klinikum 1, 07747 Jena, Germany
1 shared publication - Tanja Groten
Medizinische Fakultät, Universität zu Köln, Germany
1 shared publication - Thomas Lehmann
Institute for Medical Statistics, Computer Science and Data Science, Jena University Hospital, Jena
1 shared publication
Latest Publications
- Open Access
- 21 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1719
Sonographic Flow-Mediated Dilation Imaging versus Electronic EndoCheck Flow-Mediated Slowing by VICORDER in Pregnant Women—A Comparison of Two Methods to Evaluate Vascular Function in Pregnancy
The evaluation of endothelial function is gaining interest and importance during pregnancy, since the impaired adaptation in early pregnancy has been associated with an increased risk in preeclampsia and fetal growth restriction. To standardize the risk assessment and to implement the evaluation of vascular function in routine pregnancy care, a suitable, accurate and easy to use method is needed. Flow-mediated dilatation (FMD) of the brachial artery assessed by ultrasound is considered to be the gold standard for measuring the vascular endothelial function. The challenges of the FMD measurement have so far prevented its introduction into clinical routine. The VICORDER® device allows an automated determination of the flow-mediated slowing (FMS). The equivalence of FMD and FMS has not yet been proven in pregnant women. We collected data of 20 pregnant women randomly and consecutively while they presented for a vascular function assessment in our hospital. The gestational age at investigation was between 22 and 32 weeks of gestation, three had preexisting hypertensive pregnancy disease and three were twin pregnancies. The results for FMD or FMS below 11.3% were considered to be abnormal. Comparing FMD to FMS results in our cohort revealed a convergence in 9/9 cases, indicating normal endothelial function (specificity of 100%) and a sensitivity of 72.7%. In conclusion, we verify that the FMS measurement is a convenient, automated and operator-independent test method of endothelial function in pregnant women.
- 21 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1719
Open AccessSonographic Flow-Mediated Dilation Imaging versus Electronic EndoCheck Flow-Mediated Slowing by VICORDER in Pregnant Women—A Comparison of Two Methods to Evaluate Vascular Function in Pregnancy
The evaluation of endothelial function is gaining interest and importance during pregnancy, since the impaired adaptation in early pregnancy has been associated with an increased risk in preeclampsia and fetal growth restriction. To standardize the risk assessment and to implement the evaluation of vascular function in routine pregnancy care, a suitable, accurate and easy to use method is needed. Flow-mediated dilatation (FMD) of the brachial artery assessed by ultrasound is considered to be the gold standard for measuring the vascular endothelial function. The challenges of the FMD measurement have so far prevented its introduction into clinical routine. The VICORDER® device allows an automated determination of the flow-mediated slowing (FMS). The equivalence of FMD and FMS has not yet been proven in pregnant women. We collected data of 20 pregnant women randomly and consecutively while they presented for a vascular function assessment in our hospital. The gestational age at investigation was between 22 and 32 weeks of gestation, three had preexisting hypertensive pregnancy disease and three were twin pregnancies. The results for FMD or FMS below 11.3% were considered to be abnormal. Comparing FMD to FMS results in our cohort revealed a convergence in 9/9 cases, indicating normal endothelial function (specificity of 100%) and a sensitivity of 72.7%. In conclusion, we verify that the FMS measurement is a convenient, automated and operator-independent test method of endothelial function in pregnant women.