Lotte Jacobsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lotte Jacobsen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Tentor
Coloplast A/S, Humlebæk, Denmark
2 shared publications - Malene Hornbak
Coloplast A/S, Humlebaek, Denmark
2 shared publications - Michael Kennelly
Atrium Health Wake Forest School of Medicine, Carolinas Medical Center
2 shared publications - Per Bagi
Per Bagi, PhD, Rigshospitalet, Department of Urology, Copenhagen, Denmark
2 shared publications - Troels Pedersen
Malene Hornbak Landauro, PhD, Coloplast A/S, Humlebæk, Denmark
2 shared publications - Andrei V. Krassioukov
International Collaboration on Repair Discoveries (ICORD), University of British Columbia, Vancouver, Canada
1 shared publication
Latest Publications
- Open Access
- 29 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8485
Characterizing Urine and Sediment in Individuals with Lower Urinary Tract Dysfunction Utilizing Intermittent Catheters
Background/Objectives: To perform a physicochemical characterization of urine and sediment in intermittent catheterization (IC) users and evaluate the impact of IC with micro-hole zone catheters (MHZC) and conventional two-eyelet catheters (CEC). Methods: Analysis of anonymized urine samples collected from four IC user groups with lower urinary tract dysfunction (LUTD): Newly diagnosed individuals with spinal cord injury (SCI) from an inpatient SCI clinic (A), and community-based IC users with SCI (B), multiple sclerosis (MS) (C), or other conditions than SCI or MS (D). Urine analysis included physicochemical properties, bacterial load, and sediment size, both after collection and following passage through MHZC and CEC. Results: Urine samples from 53 participants were analyzed (groups A: 11, B: 11, C: 9, D: 22). The physicochemical properties of urine were similar to reference values despite the prevalence of bacteriuria ranging from 54.5% to 77.3%. The median [99th percentile] sediment size in the total group was 8.6 µm [50.7 µm] and 8.5 µm [54.1 µm] for group A, 9.2 µm [40.3 µm] for group B, 7.9 µm [48.3 µm] for group C, and 8.9 µm [50.3 µm] for group D. Following catheter passage, the median sediment size for the total group was 8.9 µm with the MHZC and 8.9 µm with the CEC. Conclusions: This two-part study initially presented a novel approach to characterizing urine samples, including sediment from IC users, and, thereafter, an in vitro experiment using the samples to test sediment passage through MHZC and CEC. The results indicated similar urine properties and sediment sizes across groups and did not suggest differences or issues relating to urine and sediment passage through these IC technologies for these groups.
- 29 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8485
Open AccessCharacterizing Urine and Sediment in Individuals with Lower Urinary Tract Dysfunction Utilizing Intermittent Catheters
Background/Objectives: To perform a physicochemical characterization of urine and sediment in intermittent catheterization (IC) users and evaluate the impact of IC with micro-hole zone catheters (MHZC) and conventional two-eyelet catheters (CEC). Methods: Analysis of anonymized urine samples collected from four IC user groups with lower urinary tract dysfunction (LUTD): Newly diagnosed individuals with spinal cord injury (SCI) from an inpatient SCI clinic (A), and community-based IC users with SCI (B), multiple sclerosis (MS) (C), or other conditions than SCI or MS (D). Urine analysis included physicochemical properties, bacterial load, and sediment size, both after collection and following passage through MHZC and CEC. Results: Urine samples from 53 participants were analyzed (groups A: 11, B: 11, C: 9, D: 22). The physicochemical properties of urine were similar to reference values despite the prevalence of bacteriuria ranging from 54.5% to 77.3%. The median [99th percentile] sediment size in the total group was 8.6 µm [50.7 µm] and 8.5 µm [54.1 µm] for group A, 9.2 µm [40.3 µm] for group B, 7.9 µm [48.3 µm] for group C, and 8.9 µm [50.3 µm] for group D. Following catheter passage, the median sediment size for the total group was 8.9 µm with the MHZC and 8.9 µm with the CEC. Conclusions: This two-part study initially presented a novel approach to characterizing urine samples, including sediment from IC users, and, thereafter, an in vitro experiment using the samples to test sediment passage through MHZC and CEC. The results indicated similar urine properties and sediment sizes across groups and did not suggest differences or issues relating to urine and sediment passage through these IC technologies for these groups.
- Open Access
- 1 November 2023
- Published by Wolters Kluwer Health in Journal of Wound, Ostomy & Continence Nursing
- Vol. 50 (6) , 504-511
Improved Performance With the Micro-Hole Zone Intermittent Catheter
PURPOSE: To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC) in terms of flow-stop, bladder emptying, and hematuria. DESIGN: Randomized controlled crossover studies. SUBJECT AND SETTING: The sample comprised 15 male healthy volunteers (HV) and 15 IC users, along with 15 female HV and 15 IC users. The age range was lower for HV participants than for IC users (range: 20-57 years for HV vs 21-82 years for IC users). The study setting was the Department of Urology, located in Rigshospitalet, Copenhagen. METHODS: Number of flow-stop incidents, residual urine volume at first flow-stop (RV1), and dipstick hematuria were measured during and after catheterization by a health care professional (HCP) and by IC-users. Results from the 3 studies were combined for HV and IC users on RV1 and number of flow-stop incidents but separated on sex. For incidents of hematuria, an effect of underlying condition was assumed, and a combined analysis on sex was performed, separating HV and IC users. RESULTS: When compared to the micro-hole drainage zone design, catheterizations with CEC resulted in a significantly higher mean RV1 (mean difference: 49 mL in males and 32 mL in females, both P < .001) and average number of flow-stop incidents (8 and 21 times more frequent for males and females, respectively, both P < .001). The likelihood for hematuria was 5.84 higher with CEC than with micro-hole drainage hole design, P = .053, during normal micturition in HV postcatheterization. No serious adverse events were reported. CONCLUSION: The micro-hole drainage zone catheter provides IC users fewer premature flow-stops. This design feature reduces modifiable urinary tract infection risk factors, such as residual urine and micro-trauma; additional research is needed to determine its effects on bladder health.
- 1 November 2023
- Published by Wolters Kluwer Health in Journal of Wound, Ostomy & Continence Nursing
- Vol. 50 (6) , 504-511
Open AccessImproved Performance With the Micro-Hole Zone Intermittent Catheter
PURPOSE: To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC) in terms of flow-stop, bladder emptying, and hematuria. DESIGN: Randomized controlled crossover studies. SUBJECT AND SETTING: The sample comprised 15 male healthy volunteers (HV) and 15 IC users, along with 15 female HV and 15 IC users. The age range was lower for HV participants than for IC users (range: 20-57 years for HV vs 21-82 years for IC users). The study setting was the Department of Urology, located in Rigshospitalet, Copenhagen. METHODS: Number of flow-stop incidents, residual urine volume at first flow-stop (RV1), and dipstick hematuria were measured during and after catheterization by a health care professional (HCP) and by IC-users. Results from the 3 studies were combined for HV and IC users on RV1 and number of flow-stop incidents but separated on sex. For incidents of hematuria, an effect of underlying condition was assumed, and a combined analysis on sex was performed, separating HV and IC users. RESULTS: When compared to the micro-hole drainage zone design, catheterizations with CEC resulted in a significantly higher mean RV1 (mean difference: 49 mL in males and 32 mL in females, both P < .001) and average number of flow-stop incidents (8 and 21 times more frequent for males and females, respectively, both P < .001). The likelihood for hematuria was 5.84 higher with CEC than with micro-hole drainage hole design, P = .053, during normal micturition in HV postcatheterization. No serious adverse events were reported. CONCLUSION: The micro-hole drainage zone catheter provides IC users fewer premature flow-stops. This design feature reduces modifiable urinary tract infection risk factors, such as residual urine and micro-trauma; additional research is needed to determine its effects on bladder health.
- Open Access
- 13 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5266
New Intermittent Urinary Micro-Hole Zone Catheter Shows Enhanced Performance in Emptying the Bladder: A Randomised, Controlled Crossover Study
Urinary tract infections (UTIs) are common and troublesome complications of clean intermittent catheterisation (CIC) in individuals suffering from incomplete bladder emptying, which may exacerbate the underlying disease and lead to hospitalisation. Aside from the design of the intermittent catheter and its handling, a recent review highlighted residual urine as one of several UTI risk factors. A new urinary intermittent catheter with multiple micro-holes has been developed for improved bladder emptying. In a controlled crossover study, adult male CIC users were randomised for a health care professional-led catheterisation with the new micro-hole zone catheter (MHZC) and a conventional eyelet catheter (CEC) in two individual test visits to compare the number of flow-stops and the residual urine at the first flow-stop as co-primary endpoints. In 42 male CIC users, the MHZC resulted in significantly fewer flow-stop episodes compared to the CEC (mean 0.17, 95% CI [0.06, 0.45] vs. mean 1.09, 95% CI [0.75, 1.6], respectively; p < 0.001) and significantly less residual urine at the first flow-stop (mean 5.10 mL, SE [1.14] vs. mean 39.40 mL, SE [9.65], respectively; p < 0.001). No adverse events were observed in this study. The results confirm the enhanced performance of the MHZC compared to a CEC, ensuring an uninterrupted free urine flow with no need to reposition the catheter until the bladder is thoroughly empty.
- 13 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5266
Open AccessNew Intermittent Urinary Micro-Hole Zone Catheter Shows Enhanced Performance in Emptying the Bladder: A Randomised, Controlled Crossover Study
Urinary tract infections (UTIs) are common and troublesome complications of clean intermittent catheterisation (CIC) in individuals suffering from incomplete bladder emptying, which may exacerbate the underlying disease and lead to hospitalisation. Aside from the design of the intermittent catheter and its handling, a recent review highlighted residual urine as one of several UTI risk factors. A new urinary intermittent catheter with multiple micro-holes has been developed for improved bladder emptying. In a controlled crossover study, adult male CIC users were randomised for a health care professional-led catheterisation with the new micro-hole zone catheter (MHZC) and a conventional eyelet catheter (CEC) in two individual test visits to compare the number of flow-stops and the residual urine at the first flow-stop as co-primary endpoints. In 42 male CIC users, the MHZC resulted in significantly fewer flow-stop episodes compared to the CEC (mean 0.17, 95% CI [0.06, 0.45] vs. mean 1.09, 95% CI [0.75, 1.6], respectively; p < 0.001) and significantly less residual urine at the first flow-stop (mean 5.10 mL, SE [1.14] vs. mean 39.40 mL, SE [9.65], respectively; p < 0.001). No adverse events were observed in this study. The results confirm the enhanced performance of the MHZC compared to a CEC, ensuring an uninterrupted free urine flow with no need to reposition the catheter until the bladder is thoroughly empty.