Yumi Shigemoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yumi Shigemoto has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Kenji Kashiwagi
Department of Ophthalmology, School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
4 shared publications - Airi Takahashi
Department of Ophthalmology, School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
3 shared publications - Megumi Kushima
Center for Birth Cohort Studies, Interdisciplinary Graduate School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
3 shared publications - Natsuki Okabe
Department of Ophthalmology, School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
3 shared publications - Ryoji Shinohara
Center for Birth Cohort Studies, Interdisciplinary Graduate School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
3 shared publications - Zentaro Yamagata
Center for Birth Cohort Studies, Interdisciplinary Graduate School of Medicine, University of Yamanashi, Chuo 409-3898, Japan
3 shared publications
Latest Publications
- Open Access
- 5 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6883
Relationships of Body Composition with Refractive Error and Axial Length in 8-Year-Old Japanese Children
Objectives: This study aimed to examine the relationships between refractive error and axial length (AL) and body composition parameters, including obesity-related indices, in 8-year-old children enrolled in the Japan Environment and Children’s Study (JECS). Methods: From 2019 to 2022, data from the right eyes of 1866 children aged 8 years enrolled in the JECS adjunct study were analyzed. AL, noncycloplegic spherical equivalent (SE), and uncorrected visual acuity were measured. Relationships of these ocular parameters with height, weight, muscle mass, body fat percentage, the Rohrer index, and sex were evaluated. Results: The mean AL was 23.09 mm, and the mean SE was −0.52 D in the right eye. Despite the correlations of the Rohrer index with SE (r = 0.05, p = 0.02), uncorrected visual acuity expressed as logMAR (r = −0.07, p = 0.005) and AL (r = −0.06, p = 0.02) reached nominal statistical significance, and all correlation coefficients were close to zero, indicating no meaningful linear correlations. SE and logMAR showed no meaningful correlations with height, weight, muscle mass, or body fat percentage. AL showed small positive correlations with height (r = 0.17, p < 0.001) and muscle mass (r = 0.14, p < 0.001); its correlation with weight was negligible (r = 0.07, p = 0.004), and no meaningful correlation was observed with body fat percentage. Conclusions: Among 8-year-old children, the Rohrer index showed no meaningful linear correlation with refractive error, uncorrected visual acuity, or AL despite having nominally significant p-values. AL showed small positive correlations with height and muscle mass, suggesting a limited cross-sectional relationship with overall somatic size; however, the small effect sizes preclude strong conclusions. Because refraction was measured without cycloplegia, the SE findings should be interpreted cautiously, as accommodation may have shifted measurements in the myopic direction.
- 5 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6883
Open AccessRelationships of Body Composition with Refractive Error and Axial Length in 8-Year-Old Japanese Children
Objectives: This study aimed to examine the relationships between refractive error and axial length (AL) and body composition parameters, including obesity-related indices, in 8-year-old children enrolled in the Japan Environment and Children’s Study (JECS). Methods: From 2019 to 2022, data from the right eyes of 1866 children aged 8 years enrolled in the JECS adjunct study were analyzed. AL, noncycloplegic spherical equivalent (SE), and uncorrected visual acuity were measured. Relationships of these ocular parameters with height, weight, muscle mass, body fat percentage, the Rohrer index, and sex were evaluated. Results: The mean AL was 23.09 mm, and the mean SE was −0.52 D in the right eye. Despite the correlations of the Rohrer index with SE (r = 0.05, p = 0.02), uncorrected visual acuity expressed as logMAR (r = −0.07, p = 0.005) and AL (r = −0.06, p = 0.02) reached nominal statistical significance, and all correlation coefficients were close to zero, indicating no meaningful linear correlations. SE and logMAR showed no meaningful correlations with height, weight, muscle mass, or body fat percentage. AL showed small positive correlations with height (r = 0.17, p < 0.001) and muscle mass (r = 0.14, p < 0.001); its correlation with weight was negligible (r = 0.07, p = 0.004), and no meaningful correlation was observed with body fat percentage. Conclusions: Among 8-year-old children, the Rohrer index showed no meaningful linear correlation with refractive error, uncorrected visual acuity, or AL despite having nominally significant p-values. AL showed small positive correlations with height and muscle mass, suggesting a limited cross-sectional relationship with overall somatic size; however, the small effect sizes preclude strong conclusions. Because refraction was measured without cycloplegia, the SE findings should be interpreted cautiously, as accommodation may have shifted measurements in the myopic direction.
- Open Access
- 3 August 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (15) , 5454
Anterior Chamber Configuration and Its Related Factors Among 8-Year-Old Children in the Yamanashi Adjunct Study of the Japan Environment and Children’s Study
Objective: This study aims to examine the anterior chamber structure and related factors in 8-year-old children based on data from The Yamanashi Adjunct Study of the Japan Environment and Children’s Study (JECS). Methods: A total of 709 children aged 8 years (350 boys and 359 girls) who participated in the JECS Adjunct Study were included. The right eyes were primarily used for measurements. Optical Coherence Tomography (OCT) was utilized to scan the anterior chambers of the participants’ eyes. The following parameters were measured: Angle Opening Distance (AOD500, 750), Trabecular Iris Space Area (TISA500, 750), Anterior Chamber Angle (ACA500, 750), Peripheral Iris Thickness (IT500, 750), and Peripheral Corneal Thickness (PCT500, 750). The relationships between anterior chamber structure, axial length (AL), spherical equivalent (SE), logMAR (without correction), and body height were analyzed. Results: A significant negative correlation was found between SE and ACA (500: coefficient = −0.19; 750: −0.24), AOD (500: −0.19; 750: −0.24), and TISA (500: −0.17; 750: −0.23) (p < 0.001). Conversely, a significant positive correlation was observed between AL and ACA (500: 0.22; 750: 0.26), AOD (500: 0.25; 750: 0.30), and TISA (500: 0.24; 750: 0.29) (p < 0.001). Boys exhibited a longer AL (boys: girls = 23.30 ± 0.76 mm; girls = 22.79 ± 0.72 mm) and greater CT (500: boys = 812.82 ± 51.94 mm; girls = 784.48 ± 51.81 mm; 750: boys = 776.01 ± 48.64 mm; girls = 751.34 ± 49.63 mm) compared to girls (p < 0.001) despite no significant difference in body height. CT and IT showed no correlation with AL or SE, and visual acuity had minimal correlation with IT and CT. Conclusions: In our cohort of eight-year-old children, the anterior chamber angle structure correlates with ocular structures and refractive error, revealing notable differences between boys and girls.
- 3 August 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (15) , 5454
Open AccessAnterior Chamber Configuration and Its Related Factors Among 8-Year-Old Children in the Yamanashi Adjunct Study of the Japan Environment and Children’s Study
Objective: This study aims to examine the anterior chamber structure and related factors in 8-year-old children based on data from The Yamanashi Adjunct Study of the Japan Environment and Children’s Study (JECS). Methods: A total of 709 children aged 8 years (350 boys and 359 girls) who participated in the JECS Adjunct Study were included. The right eyes were primarily used for measurements. Optical Coherence Tomography (OCT) was utilized to scan the anterior chambers of the participants’ eyes. The following parameters were measured: Angle Opening Distance (AOD500, 750), Trabecular Iris Space Area (TISA500, 750), Anterior Chamber Angle (ACA500, 750), Peripheral Iris Thickness (IT500, 750), and Peripheral Corneal Thickness (PCT500, 750). The relationships between anterior chamber structure, axial length (AL), spherical equivalent (SE), logMAR (without correction), and body height were analyzed. Results: A significant negative correlation was found between SE and ACA (500: coefficient = −0.19; 750: −0.24), AOD (500: −0.19; 750: −0.24), and TISA (500: −0.17; 750: −0.23) (p < 0.001). Conversely, a significant positive correlation was observed between AL and ACA (500: 0.22; 750: 0.26), AOD (500: 0.25; 750: 0.30), and TISA (500: 0.24; 750: 0.29) (p < 0.001). Boys exhibited a longer AL (boys: girls = 23.30 ± 0.76 mm; girls = 22.79 ± 0.72 mm) and greater CT (500: boys = 812.82 ± 51.94 mm; girls = 784.48 ± 51.81 mm; 750: boys = 776.01 ± 48.64 mm; girls = 751.34 ± 49.63 mm) compared to girls (p < 0.001) despite no significant difference in body height. CT and IT showed no correlation with AL or SE, and visual acuity had minimal correlation with IT and CT. Conclusions: In our cohort of eight-year-old children, the anterior chamber angle structure correlates with ocular structures and refractive error, revealing notable differences between boys and girls.
- Open Access
- 12 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5929
Refractive Error and Axial Length and Their Related Factors in 8-Year-Old Japanese Children: The Yamanashi Adjunct Study of the Japan Environment and Children’s Study (JECS)
Purpose: To investigate the distribution of visual acuity, refractive error, and axial length in 8-year-old children who participated in an additional survey in Yamanashi Prefecture of the Japan Environmental Children’s Study (hereafter referred to as JECS-Y) conducted from 2019 to 2021. Participants and Methods: Eight-year-old children who participated in the JECS-Y study were subjected to noncycloplegic measurements of refractive error and axial length. If the uncorrected visual acuity was less than 20/20, the best corrected visual acuity was evaluated in accordance with the autorefraction data. A questionnaire was administered regarding the parent’s history of eyeglass wear or contact lens use. Results: Among the 400 participating children, the rate of uncorrected visual acuity of 20/20 or better in both eyes was 70.4%. The mean equivalent spherical equivalent error for both eyes was −0.366 ± 1.016 D. The mean axial length was 23.08 ± 0.225 mm in all patients. The males showed significantly longer axial length than the females despite no differences in body height. There was a significant correlation between axial length, spherical refractive, and uncorrected visual acuity. The children of parents with a history of wearing eyeglasses or contact lenses showed a significantly more myopic equivalent refractive error than those without a history. Conclusions: This study clarified the current state of refractive error in 8-year-old children and the association of inheritance with refractive error. In addition, the axials were significantly longer in male patients.
- 12 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (18) , 5929
Open AccessRefractive Error and Axial Length and Their Related Factors in 8-Year-Old Japanese Children: The Yamanashi Adjunct Study of the Japan Environment and Children’s Study (JECS)
Purpose: To investigate the distribution of visual acuity, refractive error, and axial length in 8-year-old children who participated in an additional survey in Yamanashi Prefecture of the Japan Environmental Children’s Study (hereafter referred to as JECS-Y) conducted from 2019 to 2021. Participants and Methods: Eight-year-old children who participated in the JECS-Y study were subjected to noncycloplegic measurements of refractive error and axial length. If the uncorrected visual acuity was less than 20/20, the best corrected visual acuity was evaluated in accordance with the autorefraction data. A questionnaire was administered regarding the parent’s history of eyeglass wear or contact lens use. Results: Among the 400 participating children, the rate of uncorrected visual acuity of 20/20 or better in both eyes was 70.4%. The mean equivalent spherical equivalent error for both eyes was −0.366 ± 1.016 D. The mean axial length was 23.08 ± 0.225 mm in all patients. The males showed significantly longer axial length than the females despite no differences in body height. There was a significant correlation between axial length, spherical refractive, and uncorrected visual acuity. The children of parents with a history of wearing eyeglasses or contact lenses showed a significantly more myopic equivalent refractive error than those without a history. Conclusions: This study clarified the current state of refractive error in 8-year-old children and the association of inheritance with refractive error. In addition, the axials were significantly longer in male patients.
- Open Access
- 23 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (7) , 2460
Repeated Measurements Are Necessary for Evaluating Accurate Diurnal Rhythm Using a Self-Intraocular Pressure Measurement Device
Purpose: To investigate how many tests need to be performed to adequately assess intraocular pressure (IOP) diurnal change using a self-measuring rebound tonometer among glaucoma patients. Subjects and Methods: Adult patients with primary open-angle glaucoma were included. IOP was measured in the morning (6 AM to 9 AM), afternoon (12 PM to 3 PM), and at night (6 PM to 9 PM) for seven consecutive days. Twenty-four (7 males and 17 females, mean age 59.5 ± 11.0 years) patients who successfully measured IOP at least three times per day during the correct time periods for four days were subjected to analysis. Results: The IOP rhythm was significantly greater on the first day of measurement (6.6 ± 3.6 mmHg) than that averaged during subsequent days (4.4 ± 2.2 mmHg). The time of the highest and lowest IOP measurements on the first day of IOP measurement and during the entire measurement period coincided in 72.9% and 64.6% of cases, respectively. The concordance rate of the highest IOP time between the whole measurement period and each measurement day was less than 60%. Conclusion: The diurnal IOP rhythm measured by the patients themselves was not consistent, and multiple days of measurements may be necessary to correctly assess diurnal IOP rhythm.
- 23 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (7) , 2460
Open AccessRepeated Measurements Are Necessary for Evaluating Accurate Diurnal Rhythm Using a Self-Intraocular Pressure Measurement Device
Purpose: To investigate how many tests need to be performed to adequately assess intraocular pressure (IOP) diurnal change using a self-measuring rebound tonometer among glaucoma patients. Subjects and Methods: Adult patients with primary open-angle glaucoma were included. IOP was measured in the morning (6 AM to 9 AM), afternoon (12 PM to 3 PM), and at night (6 PM to 9 PM) for seven consecutive days. Twenty-four (7 males and 17 females, mean age 59.5 ± 11.0 years) patients who successfully measured IOP at least three times per day during the correct time periods for four days were subjected to analysis. Results: The IOP rhythm was significantly greater on the first day of measurement (6.6 ± 3.6 mmHg) than that averaged during subsequent days (4.4 ± 2.2 mmHg). The time of the highest and lowest IOP measurements on the first day of IOP measurement and during the entire measurement period coincided in 72.9% and 64.6% of cases, respectively. The concordance rate of the highest IOP time between the whole measurement period and each measurement day was less than 60%. Conclusion: The diurnal IOP rhythm measured by the patients themselves was not consistent, and multiple days of measurements may be necessary to correctly assess diurnal IOP rhythm.