Michał Sajdek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michał Sajdek has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandra Gąsecka
1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
2 shared publications - Alicja Dryjańska-Lamparska
Department of Clinical Radiology, Medical University of Warsaw, Poland
2 shared publications - Edyta Maj
Department of Clinical Radiology, Medical University of Warsaw, Poland
2 shared publications - Grzegorz Procyk
1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
2 shared publications - Krzysztof Jacek Lamparski
Department of Clinical Radiology, Medical University of Warsaw, Poland
2 shared publications - Magdalena Januszewicz
II Department of Radiology, Medical University of Warsaw, Poland
2 shared publications
Latest Publications
- Open Access
- 11 June 2025
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 90, 299-306
Quantitative brain volumetry in neurological disorders: from disease mechanisms to software solutions
Quantitative magnetic resonance imaging (MRI) volumetry has become a pivotal component in modern neurology, bridging the gap between detailed neuroimaging and clinical decision-making. By employing advanced imaging techniques like 3D T1-weighted, T2-weighted, and fluid-attenuated inversion recovery (FLAIR) sequences, MRI volumetry enables clinicians to objectively quantify brain volume changes associated with neurological conditions such as Alzheimer’s disease, multiple sclerosis, epilepsy, and myotonic dystrophy. Automated segmentation tools, including FreeSurfer, NeuroQuant, volBrain, and AccuBrain, facilitate precise and reproducible analysis of structural brain changes, contributing significantly to early diagnosis, patient monitoring, and therapeutic planning. In Alzheimer’s disease, volumetric MRI enables the detection of early hippocampal and temporal lobe atrophy, providing a crucial biomarker for diagnosis and monitoring disease progression. Similarly, in multiple sclerosis, volumetric analyses quantify grey and white matter degeneration, reflecting motor and cognitive impairment severity. Moreover, quantitative MRI techniques precisely delineate structural abnormalities like hippocampal sclerosis and focal cortical dysplasia in epilepsy, crucial for accurate surgical intervention. Ongoing advances in artificial intelligence and machine learning are set to further enhance these volumetric approaches, addressing current limitations such as inter-observer variability and expanding their clinical applicability. This review outlines the existing landscape and future trajectory of quantitative MRI volumetry, underscoring its expanding role in clinical neurology and personalised medicine.
- 11 June 2025
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 90, 299-306
Open AccessQuantitative brain volumetry in neurological disorders: from disease mechanisms to software solutions
Quantitative magnetic resonance imaging (MRI) volumetry has become a pivotal component in modern neurology, bridging the gap between detailed neuroimaging and clinical decision-making. By employing advanced imaging techniques like 3D T1-weighted, T2-weighted, and fluid-attenuated inversion recovery (FLAIR) sequences, MRI volumetry enables clinicians to objectively quantify brain volume changes associated with neurological conditions such as Alzheimer’s disease, multiple sclerosis, epilepsy, and myotonic dystrophy. Automated segmentation tools, including FreeSurfer, NeuroQuant, volBrain, and AccuBrain, facilitate precise and reproducible analysis of structural brain changes, contributing significantly to early diagnosis, patient monitoring, and therapeutic planning. In Alzheimer’s disease, volumetric MRI enables the detection of early hippocampal and temporal lobe atrophy, providing a crucial biomarker for diagnosis and monitoring disease progression. Similarly, in multiple sclerosis, volumetric analyses quantify grey and white matter degeneration, reflecting motor and cognitive impairment severity. Moreover, quantitative MRI techniques precisely delineate structural abnormalities like hippocampal sclerosis and focal cortical dysplasia in epilepsy, crucial for accurate surgical intervention. Ongoing advances in artificial intelligence and machine learning are set to further enhance these volumetric approaches, addressing current limitations such as inter-observer variability and expanding their clinical applicability. This review outlines the existing landscape and future trajectory of quantitative MRI volumetry, underscoring its expanding role in clinical neurology and personalised medicine.
- Open Access
- 26 May 2025
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 90, 224-233
Imaging modalities used in follow-up after coil embolization of splenic artery aneurysm – a systematic review
Purpose: Endovascular procedures have become the method of choice for treating splenic artery aneurysms (SSAs). However, there is no consensus regarding the intervals and imaging methods for follow-up examinations in patients with true SAAs treated with coil embolisation. We aimed to evaluate the utility of digital subtraction angiography (DSA), computed tomography angiography (CTA), magnetic resonance angiography (MRA), contrast-enhanced ultrasound, and duplex ultrasound (DUS) for follow-up screening of patients with SAAs treated with coil embolisation.Material and methods: We conducted a systematic review according to the PRISMA 2020 Statement. We searched 5 databases: Embase, Medline Ultimate, PubMed, Scopus, and Web of Science, each up to 10 April 2024. Eventually, 20 relevant original studies were included.Results: DSA is an invasive procedure that requires ionising radiation and should not be performed as a routine check-up. CTA is an appropriate examination method in patients immediately after coil embolisation in whom severe complications, primarily bleeding, are suspected. Still, it is unsuitable for assessing persistent aneurysmal sac perfusion. MRA is a promising noninvasive technique that does not require ionising radiation. Several studies have demonstrated the superiority of MRA over DSA in detecting small aneurysmal sac reperfusion. DUS, while not a standalone method, may supplement MRA in patients at low risk of reintervention.Conclusions: The evidence regarding follow-up imaging methods after SAAs coil embolisation is limited and of low quality. MRA should be preferred over DSA for detecting aneurysmal sac reperfusion. Due to artifacts, CTA is suitable for emergency cases but not for routine follow-up.
- 26 May 2025
- Published by Termedia Sp. z.o.o. in Polish Journal of Radiology
- Vol. 90, 224-233
Open AccessImaging modalities used in follow-up after coil embolization of splenic artery aneurysm – a systematic review
Purpose: Endovascular procedures have become the method of choice for treating splenic artery aneurysms (SSAs). However, there is no consensus regarding the intervals and imaging methods for follow-up examinations in patients with true SAAs treated with coil embolisation. We aimed to evaluate the utility of digital subtraction angiography (DSA), computed tomography angiography (CTA), magnetic resonance angiography (MRA), contrast-enhanced ultrasound, and duplex ultrasound (DUS) for follow-up screening of patients with SAAs treated with coil embolisation.Material and methods: We conducted a systematic review according to the PRISMA 2020 Statement. We searched 5 databases: Embase, Medline Ultimate, PubMed, Scopus, and Web of Science, each up to 10 April 2024. Eventually, 20 relevant original studies were included.Results: DSA is an invasive procedure that requires ionising radiation and should not be performed as a routine check-up. CTA is an appropriate examination method in patients immediately after coil embolisation in whom severe complications, primarily bleeding, are suspected. Still, it is unsuitable for assessing persistent aneurysmal sac perfusion. MRA is a promising noninvasive technique that does not require ionising radiation. Several studies have demonstrated the superiority of MRA over DSA in detecting small aneurysmal sac reperfusion. DUS, while not a standalone method, may supplement MRA in patients at low risk of reintervention.Conclusions: The evidence regarding follow-up imaging methods after SAAs coil embolisation is limited and of low quality. MRA should be preferred over DSA for detecting aneurysmal sac reperfusion. Due to artifacts, CTA is suitable for emergency cases but not for routine follow-up.
- 29 July 2024
- Published by "Medycyna Praktyczna" Spolka Jawna in Polish Archives of Internal Medicine
- Vol. 134 (11)
Conquering the giant: successful endovascular treatment of renal arteriovenous fistula
DOI: 10.20452/pamw.16812, Published online: July 29, 2024, Authors: Zuzanna Wojtczak, Michał Sajdek, Krzysztof Lamparski, Rafał Maciąg, Magdalena Januszewicz, Zbigniew Gałązka
- 29 July 2024
- Published by "Medycyna Praktyczna" Spolka Jawna in Polish Archives of Internal Medicine
- Vol. 134 (11)
Conquering the giant: successful endovascular treatment of renal arteriovenous fistula
DOI: 10.20452/pamw.16812, Published online: July 29, 2024, Authors: Zuzanna Wojtczak, Michał Sajdek, Krzysztof Lamparski, Rafał Maciąg, Magdalena Januszewicz, Zbigniew Gałązka
- Open Access
- 19 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (3) , 792
Can Color Doppler Ultrasound Be Effectively Used as the Follow-Up Modality in Patients Undergoing Splenic Artery Aneurysm Embolization? A Correlational Study between Doppler Ultrasound, Magnetic Resonance Angiography and Digital Subtraction Angiography
Splenic artery aneurysm (SAAs) rupture is associated with a high mortality rate. Regular surveillance with imaging before and after intervention is crucial to guide best evidence treatment. The following study aimed to determine the efficacy of color Doppler ultrasound imaging (DUS) compared to digital subtraction angiography (DSA) and magnetic resonance angiography (MRA) as a follow-up modality after selective coil embolization of true SAAs. We analyzed data from 20 patients, 15 females (48.1 ± 16.1 years) undergoing selective SAA coil embolization using detachable fibered embolization coils. Imaging using DUS, MRA, and DSA was performed 3 months after the initial embolization or the consequent re-embolization procedure. Primary clinical success, defined as Class I aneurysm occlusion, on 3-month follow-up was seen in 16 (80.0%) patients. DUS had a sensitivity of 94.4% and a specificity of 42.9% when compared to DSA and 92.3% and 30%, respectively, when compared to MRA in identifying Class I aneurysm occlusion. The positive predictive value (PPV) of DUS in identifying the need for re-embolization was 75.0%, while the NPV of DUS in these terms was 90.5%. DUS showed a high sensitivity in detecting aneurysm occlusion and clinical success, simultaneously exhibiting poor specificity. Still, with caution, this follow-up modality could be used for monitoring select low-risk patients after selective embolization of SAAs. DUS could provide a higher cost-to-benefit ratio, enabling more systematic post-procedural follow-up, as it is far more commonly used compared to MRA and non-invasive compared to DSA.
- 19 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (3) , 792
Open AccessCan Color Doppler Ultrasound Be Effectively Used as the Follow-Up Modality in Patients Undergoing Splenic Artery Aneurysm Embolization? A Correlational Study between Doppler Ultrasound, Magnetic Resonance Angiography and Digital Subtraction Angiography
Splenic artery aneurysm (SAAs) rupture is associated with a high mortality rate. Regular surveillance with imaging before and after intervention is crucial to guide best evidence treatment. The following study aimed to determine the efficacy of color Doppler ultrasound imaging (DUS) compared to digital subtraction angiography (DSA) and magnetic resonance angiography (MRA) as a follow-up modality after selective coil embolization of true SAAs. We analyzed data from 20 patients, 15 females (48.1 ± 16.1 years) undergoing selective SAA coil embolization using detachable fibered embolization coils. Imaging using DUS, MRA, and DSA was performed 3 months after the initial embolization or the consequent re-embolization procedure. Primary clinical success, defined as Class I aneurysm occlusion, on 3-month follow-up was seen in 16 (80.0%) patients. DUS had a sensitivity of 94.4% and a specificity of 42.9% when compared to DSA and 92.3% and 30%, respectively, when compared to MRA in identifying Class I aneurysm occlusion. The positive predictive value (PPV) of DUS in identifying the need for re-embolization was 75.0%, while the NPV of DUS in these terms was 90.5%. DUS showed a high sensitivity in detecting aneurysm occlusion and clinical success, simultaneously exhibiting poor specificity. Still, with caution, this follow-up modality could be used for monitoring select low-risk patients after selective embolization of SAAs. DUS could provide a higher cost-to-benefit ratio, enabling more systematic post-procedural follow-up, as it is far more commonly used compared to MRA and non-invasive compared to DSA.