Il Won Suh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Il Won Suh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chan Hee Park
Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, Korea
7 shared publications Se Rim Jang
7 shared publicationsChan Hee Park
5 shared publicationsEsensil Man Hia
5 shared publicationsCheol Sang Kim
3 shared publications- Cheol Sang Kim
Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (4) , 554-562
Why Is a Large-Bore Catheter Necessary in Large Vessel Occlusion from a Biomechanical Perspective?
Objective : Aspiration thrombectomy is a widely adopted treatment for acute ischemic stroke due to large vessel occlusion. Among several technical factors, the diameter of the aspiration catheter plays a critical role in determining thrombus fixation, aspiration efficiency, and overall procedural success. This study aimed to investigate the biomechanical effects of a larger catheter diameter on thrombus behavior and vessel wall response during aspiration thrombectomy.Methods : Finite element analysis was employed to simulate aspiration using three clinically relevant aspiration catheters with different diameters. Thrombi of two lengths and two compositions, varying in red blood cell content, were modeled to reflect clinical variability. Mechanical outcomes, including thrombus deformation, internal stress distribution, and vessel wall loading, were analyzed under standardized aspiration pressure conditions.Results : 0.080- and 0.084-inch large-bore catheters produced greater thrombus deformation and internal stress than the 0.072-inch catheter, particularly in softer thrombi with higher red blood cell content. In both 3 and 5 mm thrombi with red blood cells, deformation increased by approximately 12.3% with the 0.084-inch catheter compared to the 0.072-inch catheter. These changes indicate improved clot engagement and aspiration efficiency, while vessel stress remained within physiological limits. This mechanical advantage is partly due to greater luminal occupancy, with the 0.084-inch catheter occupying 65.6% of the vessel lumen, about 14% more than the 0.072-inch catheter.Conclusion : Large-bore aspiration catheters can enhance thrombus fixation and aspiration performance without compromising vascular integrity. These findings support the broader clinical use of larger-bore catheters in patients with large artery occlusion, particularly in cases requiring strong clot engagement and efficient recanalization.
- 1 July 2026
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 69 (4) , 554-562
Open AccessWhy Is a Large-Bore Catheter Necessary in Large Vessel Occlusion from a Biomechanical Perspective?
Objective : Aspiration thrombectomy is a widely adopted treatment for acute ischemic stroke due to large vessel occlusion. Among several technical factors, the diameter of the aspiration catheter plays a critical role in determining thrombus fixation, aspiration efficiency, and overall procedural success. This study aimed to investigate the biomechanical effects of a larger catheter diameter on thrombus behavior and vessel wall response during aspiration thrombectomy.Methods : Finite element analysis was employed to simulate aspiration using three clinically relevant aspiration catheters with different diameters. Thrombi of two lengths and two compositions, varying in red blood cell content, were modeled to reflect clinical variability. Mechanical outcomes, including thrombus deformation, internal stress distribution, and vessel wall loading, were analyzed under standardized aspiration pressure conditions.Results : 0.080- and 0.084-inch large-bore catheters produced greater thrombus deformation and internal stress than the 0.072-inch catheter, particularly in softer thrombi with higher red blood cell content. In both 3 and 5 mm thrombi with red blood cells, deformation increased by approximately 12.3% with the 0.084-inch catheter compared to the 0.072-inch catheter. These changes indicate improved clot engagement and aspiration efficiency, while vessel stress remained within physiological limits. This mechanical advantage is partly due to greater luminal occupancy, with the 0.084-inch catheter occupying 65.6% of the vessel lumen, about 14% more than the 0.072-inch catheter.Conclusion : Large-bore aspiration catheters can enhance thrombus fixation and aspiration performance without compromising vascular integrity. These findings support the broader clinical use of larger-bore catheters in patients with large artery occlusion, particularly in cases requiring strong clot engagement and efficient recanalization.
- Open Access
- 1 February 2025
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 13 (2) , 709-718
Diabolical ironclad beetle elytra-inspired flexible WE43 magnesium endovascular stent structures and their biomechanical potential
- 1 February 2025
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 13 (2) , 709-718
Open AccessDiabolical ironclad beetle elytra-inspired flexible WE43 magnesium endovascular stent structures and their biomechanical potential
- 28 August 2024
- Published by Elsevier in Carbohydrate Polymers
- Vol. 346, 122666
Magnetically responsive micro-clustered calcium phosphate-reinforced cell-laden microbead sodium alginate hydrogel for accelerated osteogenic tissue regeneration
- 28 August 2024
- Published by Elsevier in Carbohydrate Polymers
- Vol. 346, 122666
Magnetically responsive micro-clustered calcium phosphate-reinforced cell-laden microbead sodium alginate hydrogel for accelerated osteogenic tissue regeneration
- 15 August 2024
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 326
Construction of micro/nano-sized and multilayered TiO2-Based bioceramics coated with zein and calcium phosphate
- 15 August 2024
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 326
Construction of micro/nano-sized and multilayered TiO2-Based bioceramics coated with zein and calcium phosphate
- 26 March 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 487
Flower-like Ti(HPO4)2 bioceramic-laden 3D printed platform for enhanced bone regeneration via BMP signaling pathway
- 26 March 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 487
Flower-like Ti(HPO4)2 bioceramic-laden 3D printed platform for enhanced bone regeneration via BMP signaling pathway