Ece Ozkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ece Ozkan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Sibel Aysil Ozkan
Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkiye
2 shared publications - Elif Damla Gök Topak
Lokman Hekim University
1 shared publication - Emirhan Nemutlu
Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, Ankara 06100, Türkiye
1 shared publication Esen Bellur Atici
DEVA Holding A.S., R&D Center, Tekirdağ 59600, Türkiye
1 shared publicationGöksu Ozcelikay
Ankara University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06560, Turkiye
1 shared publication- Omer Dizdar
Department of Medical Oncology, Hacettepe University Cancer Institute, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 8 August 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (33) , 35645-35653
Molecularly Imprinted Electrochemical Sensor for the Ultrasensitive and Selective Detection of Venetoclax
In this study, a new electropolymerized molecularly imprinted polymer (MIP) film was synthesized on a glassy carbon electrode (GCE) by a photopolymerization (PP) method using acrylamide (AA) as a functional monomer and venetoclax (VEN) as a template molecule. Optimization steps of the MIP film were performed using ferrocyanide/ferricyanide [Fe(CN)6]3-/4- as a redox probe. Removal and rebinding of the template molecule were investigated by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The analytical performance of PP-AA@MIP-GCE was evaluated by comparing the DPV response of MIP with that of nonimprinted polymer (NIP). The limit of detection (LOD) and limit of quantification (LOQ) for DPV determination of VEN on PP-AA@MIP-GCE were 0.016 and 0.055 pM, respectively, and the linearity range was found to be between 0.1 and 1.0 pM. The applicability and legitimacy of the constructed sensor were confirmed through its utilization on synthetic human serum. The selectivity of the sensor was demonstrated using molecules with structures similar to that of VEN and/or drug substances such as ibrutinib and azacitidine, which could potentially be used in combination with VEN. The developed PP-AA@MIP-GCE sensor exhibited high sensitivity and selectivity for VEN and is the first reported method for DPV determination of VEN.
- 8 August 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (33) , 35645-35653
Open AccessMolecularly Imprinted Electrochemical Sensor for the Ultrasensitive and Selective Detection of Venetoclax
In this study, a new electropolymerized molecularly imprinted polymer (MIP) film was synthesized on a glassy carbon electrode (GCE) by a photopolymerization (PP) method using acrylamide (AA) as a functional monomer and venetoclax (VEN) as a template molecule. Optimization steps of the MIP film were performed using ferrocyanide/ferricyanide [Fe(CN)6]3-/4- as a redox probe. Removal and rebinding of the template molecule were investigated by differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The analytical performance of PP-AA@MIP-GCE was evaluated by comparing the DPV response of MIP with that of nonimprinted polymer (NIP). The limit of detection (LOD) and limit of quantification (LOQ) for DPV determination of VEN on PP-AA@MIP-GCE were 0.016 and 0.055 pM, respectively, and the linearity range was found to be between 0.1 and 1.0 pM. The applicability and legitimacy of the constructed sensor were confirmed through its utilization on synthetic human serum. The selectivity of the sensor was demonstrated using molecules with structures similar to that of VEN and/or drug substances such as ibrutinib and azacitidine, which could potentially be used in combination with VEN. The developed PP-AA@MIP-GCE sensor exhibited high sensitivity and selectivity for VEN and is the first reported method for DPV determination of VEN.