JJJan Ulrich Jansen

Jan Ulrich Jansen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Ulrich Jansen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Chondroitinase Versus Papain Digestion Leads to Different Outcome for In Vitro Simulation of Degenerated Discs

    by Jan Ulrich Jansen, Graciosa Quelhas Teixeira, Elias Salzer, Andrea Vernengo, Sibylle Grad, Keita Ito, Cornelia Neidlinger‐Wilke, Hans‐Joachim Wilke

    Background: Biomaterials play an increasing role in intervertebral disc regeneration and require preclinical testing, typically performed using organ culture and in vitro models. Native human discs are limited, and animal models often fail to mimic human disc degeneration. Thus, enzymes like chondroitinase ABC (chABC) and papain are used to simulate degenerative tissue changes and enable biomaterial injection. In previous work, we characterized the biomechanical and morphological effects of papain, which forms cavities in the disc. In contrast, chABC does not form cavities, but its biomechanical effects remain insufficiently characterized. This study aims to evaluate the macroscopic and biomechanical effects of chABC—specifically, range of motion (ROM), neutral zone (NZ), and disc height—in a bovine organ culture model, and assess the distribution of an injected hydrogel, comparing the results to published papain data. Methods: Four groups of fresh bovine tail segments were prepared ( n ≥ 10) and three received injections of chABC, papain, or PBS, followed by 7 days of culture. For papain and PBS, published data were supplemented with new specimens. Complex simulated physiological loading was applied to diminish disc swelling. The maximum volume of a serum‐albumin‐hydrogel was injected into all four groups. ROM, NZ, and disc height were measured before and after enzyme treatment, loading, and injection. Post‐injection, microCT scans visualized material distribution within the discs. Results: ChABC increased ROM by up to 92.1%, NZ by up to 79.4%, and decreased disc height by 2.1 mm. Hydrogel injection decreased ROM and NZ but increased disc height in all groups while enzyme treatments allowed more hydrogel injection (0.6 mL for chABC). Exemplary scans showed cloud‐like hydrogel spread for chABC and a round‐shaped degradation defect for papain. Conclusions: The findings indicate that chABC better simulates disc degeneration, whereas papain better models nucleotomies, and both enzymes preserve annulus integrity—providing valuable models for biomechanical testing.


  • Open Access

    Automated extraction of vertebral bone mineral density from imaging with various scan parameters: a cadaver study with correlation to quantitative computed tomography

    by Constanze Ramschütz, Christopher Kloth, Daniel Vogele, Thomas Baum, Sebastian Rühling, Meinrad Beer, Jan U. Jansen, Benedikt Schlager, Hans-Joachim Wilke, Jan S. Kirschke, et al.

    Purpose: To investigate lumbar vertebral volumetric bone mineral density (vBMD) from ex vivo opportunistic multi-detector computed tomography (MDCT) scans using different protocols, and compare it to dedicated quantitative CT (QCT) values from the same specimens. Methods: Cadavers from two female donors (ages 62 and 68 years) were scanned (L1–L5) using six different MDCT protocols and one dedicated QCT scan. Opportunistic vBMD was extracted using an artificial intelligence-based algorithm. The vBMD measurements from the six MDCT protocols, which varied in peak tube voltage (80–140 kVp), tube load (72–200 mAs), slice thickness (0.75–1 mm), and/or slice increment (0.5–0.75 mm), were compared to those obtained from dedicated QCT. Results: A strong positive correlation was observed between vBMD from opportunistic MDCT and reference QCT (ρ = 0.869, p < 0.01). Agreement between vBMD measurements from MDCT protocols and the QCT reference standard according to the intraclass correlation coefficient (ICC) was 0.992 (95% confidence interval [CI]: 0.982–0.998). Bland-Altman analysis showed biases ranging from − 12.66 to 8.00 mg/cm³ across the six MDCT protocols, with all data points falling within the respective limits of agreement (LOA) for both cadavers. Conclusion: Opportunistic vBMD measurements of lumbar vertebrae demonstrated reliable consistency ex vivo across various scan parameters when compared to dedicated QCT.


  • Open Access

    Prediction of screw loosening by measuring the insertion torque in non-osteoporotic patients: an in vitro study

    by Jan Ulrich Jansen, Laura Zengerle, Carsten Hackenbroch, Jens Dreyhaupt, Youping Tao, Hans-Joachim Wilke

    Background: Pedicle screws are commonly used in spinal surgeries, but screw loosening remains a major concern, even in non-osteoporotic patients. Predicting pedicle screw stability via the insertion torque is a controversial topic, mainly studied on osteoporotic cadavers. Whether the insertion torque is suitable for patients with healthy bone mineral density (BMD) remains unknown. The aim was to investigate the influencing factors, namely insertion torque, BMD, screw diameter, length, surface area, volume, screw-in rotations, vertebral level, on the screw loosening stability during distractions and to understand if intra-operative predictions are possible. Methods: Non-osteoporotic thoraco-lumbar vertebrae (n = 50) were used to implant five different pedicle screws (n = 100) while measuring the insertion torque. After embedding the endplates, the force needed to distract the screw head by 1 mm was tested. Results: The insertion toque (2.3 ± 0.9 Nm) showed the highest influence on the distraction force (324.8 ± 84.4 N) followed by the screw size and vertebral level. BMD did not show any effects. Conclusions: The linear correlation of insertion torque and the bending force suggests an alternative prediction metric for screw loosening which could improve the outcome of surgeries and patients’ safety. This is potentially a simple, intra-operative method, which can be used in future.


  • Open Access

    A novel spine tester TO GO

    by Jan Ulrich Jansen, Laura Zengerle, Marcel Steiner, Vincenza Sciortino, Marianna Tryfonidou, Hans‐Joachim Wilke

    Background: Often after large animal experiments in spinal research, the question arises—histology or biomechanics? While biomechanics are essential for informed decisions on the functionality of the therapy being studied, scientists often choose histological analysis alone. For biomechanical testing, for example, flexibility, specimens must be shipped to institutions with special testing equipment, as spine testers are complex and immobile. The specimens must usually be shipped frozen, and, thus, biological and histological investigations are not possible anymore. To allow both biomechanical and biological investigations with the same specimen and, thus, to reduce the number of required animals, the aim of the study was to develop a spine tester that can be shipped worldwide to test on‐site.Methods: The “Spine Tester TO GO” was designed consisting of a frame with three motors that initiate pure moments and rotate the specimen in three motion planes. A load cell and an optical motion tracking system controlled the applied loads and measured range of motion (ROM) and neutral zone (NZ). As a proof of concept, the new machine was validated and compared under real experimental conditions with an existing testing machine already validated employing fresh bovine tail discs CY34 (n = 10).Results: The new spine tester measured reasonable ROM and NZ from hysteresis curves, and the ROM of the two testing machines formed a high coefficient of determination R2 = 0.986. However, higher ROM results of the new testing machine might be explained by the lower friction of the air bearings, which allowed more translational motion.Conclusions: The spine tester TO GO now opens up new opportunities for on‐site flexibility tests and contributes hereby to the 3R principle by limiting the number of experimental animals needed to obtain full characterization of spine units at the macroscopic, biomechanical, biochemical, and histological level.


  • Open Access

    Papain Injection Creates a Nucleotomy-like Cavity for Testing Gels in Intervertebral Discs

    by Jan Ulrich Jansen, Graciosa Quelhas Teixeira, Andrea Vernengo, Sybille Grad, Cornelia Neidlinger-Wilke, Hans-Joachim Wilke

    Biomaterials, such as hydrogels, have an increasingly important role in the development of regenerative approaches for the intervertebral disc. Since animal models usually resist biomaterial injection due to high intradiscal pressure, preclinical testing of the biomechanical performance of biomaterials after implantation remains difficult. Papain reduces the intradiscal pressure, creates cavities within the disc, and allows for biomaterial injections. But papain digestion needs time, and cadaver experiments that are limited to 24 h for measuring range of motion (ROM) cannot not be combined with papain digestion just yet. In this study, we successfully demonstrate a new organ culture approach, facilitating papain digestion to create cavities in the disc and the testing of ROM, neutral zone (NZ), and disc height. Papain treatment increased the ROM by up to 109.5%, extended NZ by up to 210.9%, and decreased disc height by 1.96 ± 0.74 mm. A median volume of 0.73 mL hydrogel could be injected after papain treatment, and histology revealed a strong loss of proteoglycans in the remaining nucleus tissue. Papain has the same biomechanical effects as known from nucleotomies or herniations and thus creates a disc model to study such pathologies in vitro. This new model can now be used to test the performance of biomaterials.


  • Open Access

    Oestrogen and Vibration Improve Intervertebral Disc Cell Viability and Decrease Catabolism in Bovine Organ Cultures

    by Franziska Widmayer, Cornelia Neidlinger-Wilke, Fiona Witz, Jan U. Jansen, Anita Ignatius, Melanie Haffner-Luntzer, Graciosa Q. Teixeira

    Postmenopausal women are at an increased risk for intervertebral disc degeneration, possibly due to the decrease in oestrogen levels. Low-magnitude, high-frequency vibration (LMHFV) is applied as a therapeutic approach for postmenopausal osteoporosis; however, less is known regarding possible effects on the intervertebral disc (IVD) and whether these may be oestrogen-dependent. The present study investigated the effect of 17β-oestradiol (E2) and LMHFV in an IVD organ culture model. Bovine IVDs (n = 6 IVDs/group) were treated with either (i) E2, (ii) LMHFV or (iii) the combination of E2 + LMHFV for 2 or 14 days. Minor changes in gene expression, cellularity and matrix metabolism were observed after E2 treatment, except for a significant increase in matrix metalloproteinase (MMP)-3 and interleukin (IL)-6 production. Interestingly, LMHFV alone induced cell loss and increased IL-6 production compared to the control. The combination of E2 + LMHFV induced a protective effect against cell loss and decreased IL-6 production compared to the LMHFV group. This indicates possible benefits of oestrogen therapy for the IVDs of postmenopausal women undergoing LMHFV exercises.