Bin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bin Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Qiwei Jian
School of mechanical and automotive engineering, Shanghai University of Engineering Science, Shanghai 201620, China
3 shared publications Chengzhi Dong
Shanghai Duratt Instrument Co., Ltd., Shanghai 201613, P. R. China
2 shared publicationsTianqi Chen
Shanghai Duratt Instrument Co., Ltd., Shanghai 201613, P. R. China
2 shared publications- Aiwu Yang
College of Environmental Science and Engineering, Donghua University, Shanghai 201620, China
1 shared publication - Bo Yu
China Railway Water Group Co., Ltd., Xi’an 710000, China
1 shared publication - Gamal Kamel Hassan
Water Pollution Research Department, National Research Centre, 33 Behooth St., Dokki, Giza P.O. Box 12622, Egypt
1 shared publication
Latest Publications
- Open Access
- 6 June 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (12) , 5253
Toward Sustainable Soil Remediation: Progress and Perspectives on Biochar-Activated Persulfate Oxidation
Organic soil pollution poses a persistent threat to environmental sustainability by disrupting nutrient cycling and ecosystem functioning. The biochar-activated persulfate (PS)-based advanced oxidation process (AOP) has emerged as a promising strategy for the sustainable remediation of organic-contaminated soils. This review provides a comprehensive overview of the recent progress in the PS-based degradation of organic pollutants, with a particular focus on the role of biochar as an efficient and environmental activator. This review further summarizes advancements in the design of modified biochars, including metal (Fe, Cu, Co, Mn, Zn, and La), non-metal (N, S, B, P), and functional group modifications, aimed at enhancing the PS activation efficiency while minimizing secondary environmental risks. Importantly, the overlooked contributions of soil microorganisms in PS/biochar systems are discussed, highlighting their potential to complement chemical oxidation and contribute to eco-compatible remediation pathways. This review emphasizes the sustainability-oriented evolution of PS/biochar technology, highlighting the importance of a cost-efficient implementation, ecological compatibility, and the rational engineering of smart, regenerable catalysts. These insights support the advancement of PS/biochar-based AOPs toward scalable, intelligent, and environmentally sustainable soil remediation.
- 6 June 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (12) , 5253
Open AccessToward Sustainable Soil Remediation: Progress and Perspectives on Biochar-Activated Persulfate Oxidation
Organic soil pollution poses a persistent threat to environmental sustainability by disrupting nutrient cycling and ecosystem functioning. The biochar-activated persulfate (PS)-based advanced oxidation process (AOP) has emerged as a promising strategy for the sustainable remediation of organic-contaminated soils. This review provides a comprehensive overview of the recent progress in the PS-based degradation of organic pollutants, with a particular focus on the role of biochar as an efficient and environmental activator. This review further summarizes advancements in the design of modified biochars, including metal (Fe, Cu, Co, Mn, Zn, and La), non-metal (N, S, B, P), and functional group modifications, aimed at enhancing the PS activation efficiency while minimizing secondary environmental risks. Importantly, the overlooked contributions of soil microorganisms in PS/biochar systems are discussed, highlighting their potential to complement chemical oxidation and contribute to eco-compatible remediation pathways. This review emphasizes the sustainability-oriented evolution of PS/biochar technology, highlighting the importance of a cost-efficient implementation, ecological compatibility, and the rational engineering of smart, regenerable catalysts. These insights support the advancement of PS/biochar-based AOPs toward scalable, intelligent, and environmentally sustainable soil remediation.
- 6 November 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 25 (04)
A SPECIALIZED SYSTEM FOR IN VITRO TEST OF ANATOMIC GLENOIDS BASED ON ASTM F2028-14
Glenoid loosening, primarily induced by the “rocking horse” phenomenon from humeral head load on the glenoid rim, is the foremost complication and cause of failure in anatomic total shoulder arthroplasty. The dynamic load exerted by universal fatigue testing machines significantly deviates from the standard ASTM F2028-14 in the rocking test. To accurately conduct the in vitro loosening test on anatomic glenoids, a specialized system and customized test methods are developed to achieve anatomic glenoid rocking and subluxation tests. The horizontal and vertical loading can be achieved synchronously or asynchronously by two self-developed high-performance electromagnetic linear motors. In addition, the subluxation tests on anatomic glenoids are verified by finite element simulation. The results show that the subluxation load and translation of anatomic glenoids in the subluxation tests are consistent with those in numerical simulations. The error of the applied axial force in the rocking tests is only 5[ ]N, strictly meeting the standard of ASTM F2028-14. During the rocking tests, the system runs smoothly and the software works well, indicating the feasibility of the in vitro shoulder joint test system. This study provides an approach to accurate dynamic evaluation of glenoid loosening or disassociation.
- 6 November 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 25 (04)
A SPECIALIZED SYSTEM FOR IN VITRO TEST OF ANATOMIC GLENOIDS BASED ON ASTM F2028-14
Glenoid loosening, primarily induced by the “rocking horse” phenomenon from humeral head load on the glenoid rim, is the foremost complication and cause of failure in anatomic total shoulder arthroplasty. The dynamic load exerted by universal fatigue testing machines significantly deviates from the standard ASTM F2028-14 in the rocking test. To accurately conduct the in vitro loosening test on anatomic glenoids, a specialized system and customized test methods are developed to achieve anatomic glenoid rocking and subluxation tests. The horizontal and vertical loading can be achieved synchronously or asynchronously by two self-developed high-performance electromagnetic linear motors. In addition, the subluxation tests on anatomic glenoids are verified by finite element simulation. The results show that the subluxation load and translation of anatomic glenoids in the subluxation tests are consistent with those in numerical simulations. The error of the applied axial force in the rocking tests is only 5[ ]N, strictly meeting the standard of ASTM F2028-14. During the rocking tests, the system runs smoothly and the software works well, indicating the feasibility of the in vitro shoulder joint test system. This study provides an approach to accurate dynamic evaluation of glenoid loosening or disassociation.
- 8 June 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 118 (1) , 104005
Development and validation of a specialized system for self-tapping medical bone screw testing
A specialized system for accurate self-tapping medical bone screw testing is developed, fully meeting the requirements of ASTM F543-A4 (YY/T 1505-2016). The onset of self-tap is identified automatically according to a change in the slope of the torque curve. Precise load control is applied to determine the self-tapping force accurately. A simple mechanical platform is embedded to ensure the automatic axial alignment of a tested screw with the pilot hole in a test block. In addition, comparative experiments are conducted on different self-tapping screws to verify the system's effectiveness. By the automatic identification and alignment method, both torque curves and axial force curves for each screw exhibit significant consistency. The self-tapping time point derived from the torque curve agrees well with the turning point of the axial displacement curve. The determined self-tapping forces' mean values and standard deviations are both small, which are proved to be effective and accurate in the insertion tests. This work contributes to improving the standard test method for accurate determination of the self-tapping performance of medical bone screws.
- 8 June 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 118 (1) , 104005
Development and validation of a specialized system for self-tapping medical bone screw testing
A specialized system for accurate self-tapping medical bone screw testing is developed, fully meeting the requirements of ASTM F543-A4 (YY/T 1505-2016). The onset of self-tap is identified automatically according to a change in the slope of the torque curve. Precise load control is applied to determine the self-tapping force accurately. A simple mechanical platform is embedded to ensure the automatic axial alignment of a tested screw with the pilot hole in a test block. In addition, comparative experiments are conducted on different self-tapping screws to verify the system's effectiveness. By the automatic identification and alignment method, both torque curves and axial force curves for each screw exhibit significant consistency. The self-tapping time point derived from the torque curve agrees well with the turning point of the axial displacement curve. The determined self-tapping forces' mean values and standard deviations are both small, which are proved to be effective and accurate in the insertion tests. This work contributes to improving the standard test method for accurate determination of the self-tapping performance of medical bone screws.