BLBin Liu

Bin Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bin Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Toward Sustainable Soil Remediation: Progress and Perspectives on Biochar-Activated Persulfate Oxidation

    by Qiwei Jian, Xianbao Xu, Xiang Li, Aiwu Yang, Bin Liu, Bo Yu, Hussein E. Al-Hazmi, Gamal Kamel Hassan

    Organic soil pollution poses a persistent threat to environmental sustainability by disrupting nutrient cycling and ecosystem functioning. The biochar-activated persulfate (PS)-based advanced oxidation process (AOP) has emerged as a promising strategy for the sustainable remediation of organic-contaminated soils. This review provides a comprehensive overview of the recent progress in the PS-based degradation of organic pollutants, with a particular focus on the role of biochar as an efficient and environmental activator. This review further summarizes advancements in the design of modified biochars, including metal (Fe, Cu, Co, Mn, Zn, and La), non-metal (N, S, B, P), and functional group modifications, aimed at enhancing the PS activation efficiency while minimizing secondary environmental risks. Importantly, the overlooked contributions of soil microorganisms in PS/biochar systems are discussed, highlighting their potential to complement chemical oxidation and contribute to eco-compatible remediation pathways. This review emphasizes the sustainability-oriented evolution of PS/biochar technology, highlighting the importance of a cost-efficient implementation, ecological compatibility, and the rational engineering of smart, regenerable catalysts. These insights support the advancement of PS/biochar-based AOPs toward scalable, intelligent, and environmentally sustainable soil remediation.


  • A SPECIALIZED SYSTEM FOR IN VITRO TEST OF ANATOMIC GLENOIDS BASED ON ASTM F2028-14

    by Hao Li, BIN Liu, Chengzhi Dong, Tianqi Chen, Qiwei Jian

    Glenoid loosening, primarily induced by the “rocking horse” phenomenon from humeral head load on the glenoid rim, is the foremost complication and cause of failure in anatomic total shoulder arthroplasty. The dynamic load exerted by universal fatigue testing machines significantly deviates from the standard ASTM F2028-14 in the rocking test. To accurately conduct the in vitro loosening test on anatomic glenoids, a specialized system and customized test methods are developed to achieve anatomic glenoid rocking and subluxation tests. The horizontal and vertical loading can be achieved synchronously or asynchronously by two self-developed high-performance electromagnetic linear motors. In addition, the subluxation tests on anatomic glenoids are verified by finite element simulation. The results show that the subluxation load and translation of anatomic glenoids in the subluxation tests are consistent with those in numerical simulations. The error of the applied axial force in the rocking tests is only 5[ ]N, strictly meeting the standard of ASTM F2028-14. During the rocking tests, the system runs smoothly and the software works well, indicating the feasibility of the in vitro shoulder joint test system. This study provides an approach to accurate dynamic evaluation of glenoid loosening or disassociation.

  • Development and validation of a specialized system for self-tapping medical bone screw testing

    by Wenlong Tang, Qiwei Jian, Chengzhi Dong, Tianqi Chen, Bin Liu

    A specialized system for accurate self-tapping medical bone screw testing is developed, fully meeting the requirements of ASTM F543-A4 (YY/T 1505-2016). The onset of self-tap is identified automatically according to a change in the slope of the torque curve. Precise load control is applied to determine the self-tapping force accurately. A simple mechanical platform is embedded to ensure the automatic axial alignment of a tested screw with the pilot hole in a test block. In addition, comparative experiments are conducted on different self-tapping screws to verify the system's effectiveness. By the automatic identification and alignment method, both torque curves and axial force curves for each screw exhibit significant consistency. The self-tapping time point derived from the torque curve agrees well with the turning point of the axial displacement curve. The determined self-tapping forces' mean values and standard deviations are both small, which are proved to be effective and accurate in the insertion tests. This work contributes to improving the standard test method for accurate determination of the self-tapping performance of medical bone screws.