Wanyin Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wanyin Deng has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Shijie Yang
Department of Digestive Endoscopy Center, Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China
5 shared publications- Xiaobo Li
Division of Gastroenterology and Hepatology, Key Laboratory of Gastroenterology and Hepatology, Ministry of Health, Shanghai Institute of Digestive Disease, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
4 shared publications Xiaojie Huang
4 shared publicationsXiaolu Lin
Department of Digestive Endoscopy Center, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, Fujian Province, China
4 shared publicationsGuifen Chen
3 shared publications- Xiaolu Lin
Department of Digestive Endoscopy Center, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, Fujian, China
3 shared publications
Latest Publications
- 15 April 2026
- Published by Springer Nature in Nature Health
- Vol. 1 (8) , 822-830
The global economic burden of digestive tract diseases and cancers from 2020 to 2050
- 15 April 2026
- Published by Springer Nature in Nature Health
- Vol. 1 (8) , 822-830
The global economic burden of digestive tract diseases and cancers from 2020 to 2050
- 16 January 2026
- Published by Springer Nature in European Journal of Nutrition
- Vol. 65 (1) , 29
Global burden of dietary-related mortality in working-age population, 1990–2021: trends and disparities across 204 countries and territories
- 16 January 2026
- Published by Springer Nature in European Journal of Nutrition
- Vol. 65 (1) , 29
Global burden of dietary-related mortality in working-age population, 1990–2021: trends and disparities across 204 countries and territories
- Open Access
- 1 January 2026
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 15 (1) , 39-48
Device failures and patient adverse events from EUS: 26-year FDA MAUDE analysis (2000–2025)
Background and Objectives: EUS has emerged as an essential instrument in the field of gastroenterology, significantly enhancing both diagnostic evaluations and therapeutic procedures. By delivering high-resolution imaging and precise guidance, EUS facilitates a range of interventional techniques. This study sought to examine the adverse events linked to EUS devices following their approval by the US Food and Drug Administration. Methods: We performed a retrospective analysis utilizing postmarketing surveillance data sourced from the Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database. This analysis encompasses data from January 1, 2000, to August 31, 2025. Results: A total of 7608 reports detailing 8778 device-related issues and 7875 patient complications were analyzed. The most commonly reported device-related problems included peeling or delamination, with 1251 reports, followed by device breakage at 837 reports, microbial contamination at 781 reports, and inadequate cleaning at 704 reports. In terms of patient-related complications, the most frequently reported adverse events were blood loss (73 reports), tissue perforation (44 reports), and pancreatitis (32 reports). Furthermore, there were 743 documented instances of microbial contamination in EUS devices, with Coagulase-negative staphylococci being identified as the predominant pathogen, appearing in 151 reports. Conclusions: The examination of the MAUDE database reveals significant device and patient-related adverse events that endoscopists must consider during EUS procedures. Continuous postmarketing surveillance and the evaluation of real-world data are crucial for determining the safety and effectiveness of endoscopic devices, which in turn enhances patient outcomes.
- 1 January 2026
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 15 (1) , 39-48
Open AccessDevice failures and patient adverse events from EUS: 26-year FDA MAUDE analysis (2000–2025)
Background and Objectives: EUS has emerged as an essential instrument in the field of gastroenterology, significantly enhancing both diagnostic evaluations and therapeutic procedures. By delivering high-resolution imaging and precise guidance, EUS facilitates a range of interventional techniques. This study sought to examine the adverse events linked to EUS devices following their approval by the US Food and Drug Administration. Methods: We performed a retrospective analysis utilizing postmarketing surveillance data sourced from the Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database. This analysis encompasses data from January 1, 2000, to August 31, 2025. Results: A total of 7608 reports detailing 8778 device-related issues and 7875 patient complications were analyzed. The most commonly reported device-related problems included peeling or delamination, with 1251 reports, followed by device breakage at 837 reports, microbial contamination at 781 reports, and inadequate cleaning at 704 reports. In terms of patient-related complications, the most frequently reported adverse events were blood loss (73 reports), tissue perforation (44 reports), and pancreatitis (32 reports). Furthermore, there were 743 documented instances of microbial contamination in EUS devices, with Coagulase-negative staphylococci being identified as the predominant pathogen, appearing in 151 reports. Conclusions: The examination of the MAUDE database reveals significant device and patient-related adverse events that endoscopists must consider during EUS procedures. Continuous postmarketing surveillance and the evaluation of real-world data are crucial for determining the safety and effectiveness of endoscopic devices, which in turn enhances patient outcomes.
- 10 October 2025
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 103 (4) , 808-809
Novel self-made multiloop dental floss traction device for enhanced endoscopic submucosal dissection in the gastric body (with video)
- 10 October 2025
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 103 (4) , 808-809
Novel self-made multiloop dental floss traction device for enhanced endoscopic submucosal dissection in the gastric body (with video)
- 7 April 2025
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 120 (11) , 2477
A Case of Multiple Gastrointestinal Ulcers Caused by Dental Floss Used for Endoscopic Submucosal Dissection Defect Closure
An abstract is unavailable. This article is available as a PDF only.
- 7 April 2025
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 120 (11) , 2477
A Case of Multiple Gastrointestinal Ulcers Caused by Dental Floss Used for Endoscopic Submucosal Dissection Defect Closure
An abstract is unavailable. This article is available as a PDF only.
- 30 January 2025
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 23 (10) , A27-A28
Diffuse Esophageal Adenocarcinoma
- 30 January 2025
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 23 (10) , A27-A28
Diffuse Esophageal Adenocarcinoma
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1076-E1077
Delayed bleeding after peroral endoscopic myotomy for achalasia: conquered by clearing tunnel clots and identifying the bleeding site
A 35-year-old man presented with dysphagia accompanied by regurgitation for 2 years, with his symptoms having worsened over the previous 3 months. After a series of comprehensive examinations, he was diagnosed with type 2 achalasia and underwent a successful peroral endoscopic myotomy (POEM). He developed chest pain 9 hours after the operation, which was accompanied by a small amount of hematemesis, and persisted without relief. An emergency gastroscopy indicated bleeding within the tunnel, so endoscopic hemostasis was performed with the patient under general anesthesia with tracheal intubation. During the gastroscopy, the tunnel was seen to be obviously swollen, and bleeding within the tunnel was therefore considered. The tunnel opening was re-established endoscopically, and a large number of dark red blood clots were observed ([Fig. 1] a). Removing the blood clots from the tunnel and finding the bleeding site were the key and most challenging aspects in achieving hemostasis. At first, a snare was tried to clear the blood clots; however, the tunnel filled with blood clots lacked sufficient space to open the snare. In contrast, with a clip, it was possible to more effectively grasp and remove the blood clots with fibrosis, thereby improving the efficiency of blood clot clearance. After spending 50 minutes clearing all the blood clots from the tunnel ([Fig. 1] b), we identified active oozing of blood from a blood vessel in the submucosa at the cardia ([Fig. 1] c). Hemostasis was performed by electrocoagulation under endoscopic visualization and was successfully achieved ([Fig. 1] d; [Video 1]). Re-examination 10 days after the operation showed no evidence of further bleeding in the tunnel ([Fig. 2]), and the patient was then discharged from the hospital. Bleeding within the tunnel after a POEM operation is extremely rare [1]. Once it occurs, dealing with it can be troublesome [2]. In cases of massive bleeding, the key to hemostasis lies in clearing the blood clots inside the tunnel to allow identification of the bleeding site. Endoscopy_UCTN_Code_CPL_1AH_2AZ_3AZ Article published online: 18 September 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E1076-E1077
Open AccessDelayed bleeding after peroral endoscopic myotomy for achalasia: conquered by clearing tunnel clots and identifying the bleeding site
A 35-year-old man presented with dysphagia accompanied by regurgitation for 2 years, with his symptoms having worsened over the previous 3 months. After a series of comprehensive examinations, he was diagnosed with type 2 achalasia and underwent a successful peroral endoscopic myotomy (POEM). He developed chest pain 9 hours after the operation, which was accompanied by a small amount of hematemesis, and persisted without relief. An emergency gastroscopy indicated bleeding within the tunnel, so endoscopic hemostasis was performed with the patient under general anesthesia with tracheal intubation. During the gastroscopy, the tunnel was seen to be obviously swollen, and bleeding within the tunnel was therefore considered. The tunnel opening was re-established endoscopically, and a large number of dark red blood clots were observed ([Fig. 1] a). Removing the blood clots from the tunnel and finding the bleeding site were the key and most challenging aspects in achieving hemostasis. At first, a snare was tried to clear the blood clots; however, the tunnel filled with blood clots lacked sufficient space to open the snare. In contrast, with a clip, it was possible to more effectively grasp and remove the blood clots with fibrosis, thereby improving the efficiency of blood clot clearance. After spending 50 minutes clearing all the blood clots from the tunnel ([Fig. 1] b), we identified active oozing of blood from a blood vessel in the submucosa at the cardia ([Fig. 1] c). Hemostasis was performed by electrocoagulation under endoscopic visualization and was successfully achieved ([Fig. 1] d; [Video 1]). Re-examination 10 days after the operation showed no evidence of further bleeding in the tunnel ([Fig. 2]), and the patient was then discharged from the hospital. Bleeding within the tunnel after a POEM operation is extremely rare [1]. Once it occurs, dealing with it can be troublesome [2]. In cases of massive bleeding, the key to hemostasis lies in clearing the blood clots inside the tunnel to allow identification of the bleeding site. Endoscopy_UCTN_Code_CPL_1AH_2AZ_3AZ Article published online: 18 September 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1080-E1081
Endoscopic removal of a challenging gastric foreign body causing unexplained abdominal pain
A 33-year-old woman presented with a 3-month history of upper abdominal pain, which was exacerbated by bending or twisting. Blood tests revealed no abnormalities, and pharmacological interventions failed to alleviate symptoms. Gastroscopy at a local hospital had shown a 0.6-cm firm protrusion on the greater curvature of the gastric antrum, without discoloration or texture changes, that was suspicious for a submucosal tumor (SMT) ([Fig. 1] a). However, gastroscopy at our center revealed that the lesion had shrunk in size compared to the initial assessment, casting doubt on the SMT diagnosis ([Fig. 1] b). Subsequent endoscopic ultrasound (EUS) showed a cordlike hyperechoic shadow penetrating the gastric muscular layer, suggesting the presence of a foreign body ([Fig. 1] c). Despite the patient denying ingestion of any foreign object, a computed tomography scan corroborated the EUS findings ([Fig. 1] d). Given the patient’s persistent pain and the shrinkage of the lesion, endoscopic submucosal dissection (ESD) was carried out with her consent ([Video 1]). After the lesion had been marked and a circular incision had been made, intraoperative EUS helped to locate the deeply embedded foreign body ([Fig. 2] a–c). The foreign body was carefully extracted and found to be a sharp, 2-cm metallic object (iron wire), which had caused the gastric mucosal lesion to resemble an SMT ([Fig. 2] d,e). The wound was closed with endoscopic clips, and no bleeding was observed ([Fig. 2] f). The patient was discharged 5 days after the operation, with no recurrence of pain reported at the 2-month follow-up. Ingestion of a foreign body is common and most cases are asymptomatic; only a few foreign bodies cause symptoms and complications [1] [2] [3]. In this rare case, EUS was crucial in detecting the foreign body and guiding its successful removal via ESD, highlighting the diagnostic challenges of atypical foreign bodies and the value of applying multiple endoscopic techniques for precise, minimally invasive treatment. Article published online: 04 December 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1080-E1081
Open AccessEndoscopic removal of a challenging gastric foreign body causing unexplained abdominal pain
A 33-year-old woman presented with a 3-month history of upper abdominal pain, which was exacerbated by bending or twisting. Blood tests revealed no abnormalities, and pharmacological interventions failed to alleviate symptoms. Gastroscopy at a local hospital had shown a 0.6-cm firm protrusion on the greater curvature of the gastric antrum, without discoloration or texture changes, that was suspicious for a submucosal tumor (SMT) ([Fig. 1] a). However, gastroscopy at our center revealed that the lesion had shrunk in size compared to the initial assessment, casting doubt on the SMT diagnosis ([Fig. 1] b). Subsequent endoscopic ultrasound (EUS) showed a cordlike hyperechoic shadow penetrating the gastric muscular layer, suggesting the presence of a foreign body ([Fig. 1] c). Despite the patient denying ingestion of any foreign object, a computed tomography scan corroborated the EUS findings ([Fig. 1] d). Given the patient’s persistent pain and the shrinkage of the lesion, endoscopic submucosal dissection (ESD) was carried out with her consent ([Video 1]). After the lesion had been marked and a circular incision had been made, intraoperative EUS helped to locate the deeply embedded foreign body ([Fig. 2] a–c). The foreign body was carefully extracted and found to be a sharp, 2-cm metallic object (iron wire), which had caused the gastric mucosal lesion to resemble an SMT ([Fig. 2] d,e). The wound was closed with endoscopic clips, and no bleeding was observed ([Fig. 2] f). The patient was discharged 5 days after the operation, with no recurrence of pain reported at the 2-month follow-up. Ingestion of a foreign body is common and most cases are asymptomatic; only a few foreign bodies cause symptoms and complications [1] [2] [3]. In this rare case, EUS was crucial in detecting the foreign body and guiding its successful removal via ESD, highlighting the diagnostic challenges of atypical foreign bodies and the value of applying multiple endoscopic techniques for precise, minimally invasive treatment. Article published online: 04 December 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 1 September 2023
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 98 (3) , 449-450
Resected specimen extraction using a medical glove in endoscopic submucosal dissection of a large gastric submucosal tumor (with video)
- 1 September 2023
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 98 (3) , 449-450
Resected specimen extraction using a medical glove in endoscopic submucosal dissection of a large gastric submucosal tumor (with video)