ADAnna Dietze

Anna Dietze

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anna Dietze has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Karsten Witt

    Department of Neurology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany

    4 shared publications
  • Henri Pöntynen

    Department of Medical Physics and Acoustics, University of Oldenburg, Oldenburg, Germany

    3 shared publications
  • Mathias Dietz

    Department of Medical Physics and Acoustics, University of Oldenburg, Oldenburg, Germany

    3 shared publications
  • Peter Sörös

    Department of Neurology, School of Medicine and Health Sciences, University of Oldenburg, Oldenburg, Germany

    3 shared publications
  • Anna Methner

    Department of Medical Physics and Acoustics, University of Oldenburg, Oldenburg, Germany

    2 shared publications
  • Benedikt Sundermann

    Department of Medical Physics and Acoustics, University of Oldenburg, Oldenburg, Germany

    2 shared publications

Latest Publications

  • Open Access

    Static and moving minimum audible angle: Independent contributions of reverberation and position

    by Anna Dietze, Samuel W. Clapp, Bernhard U. Seeber

    Two measures of auditory spatial resolution, the minimum audible angle and the minimum audible movement angle, have been obtained in a simulated acoustic environment using Ambisonics sound field reproduction. Trajectories were designed to provide no reliable cues for the spatial discrimination task. Larger threshold angles were found in reverberant compared to anechoic conditions, for stimuli on the side compared to the front, and for moving compared to static stimuli. The effect of reverberation appeared to be independent of the position of the sound source (same relative threshold increase) and was independently present for static and moving sound sources.


  • Open Access

    Longitudinal observations of the effects of ischemic stroke on binaural perception

    by Anna Dietze, Peter Sörös, Henri Pöntynen, Karsten Witt, Mathias Dietz

    Acute ischemic stroke, characterized by a localized reduction in blood flow to specific areas of the brain, has been shown to affect binaural auditory perception. In a previous study conducted during the acute phase of ischemic stroke, two tasks of binaural hearing were performed: binaural tone-in-noise detection, and lateralization of stimuli with interaural time- or level differences. Various lesion-specific, as well as individual, differences in binaural performance between patients in the acute phase of stroke and a control group were demonstrated. For the current study, we re-invited the same group of patients, whereupon a subgroup repeated the experiments during the subacute and chronic phases of stroke. Similar to the initial study, this subgroup consisted of patients with lesions in different locations, including cortical and subcortical areas. At the group level, the results from the tone-in-noise detection experiment remained consistent across the three measurement phases, as did the number of deviations from normal performance in the lateralization task. However, the performance in the lateralization task exhibited variations over time among individual patients. Some patients demonstrated improvements in their lateralization abilities, indicating recovery, whereas others’ lateralization performance deteriorated during the later stages of stroke. Notably, our analyses did not reveal consistent patterns for patients with similar lesion locations. These findings suggest that recovery processes are more individual than the acute effects of stroke on binaural perception. Individual impairments in binaural hearing abilities after the acute phase of ischemic stroke have been demonstrated and should therefore also be targeted in rehabilitation programs.


  • Open Access

    Auditory model-based parameter estimation and selection of the most informative experimental conditions

    by Anna Dietze, Anna-Lena Reinsch, Jörg Encke, Mathias Dietz

    Identifying the causes underlying a person’s hearing impairment is challenging. It requires linking the results of listening tests to possible pathologies of the highly non-linear auditory system. This process is further aggravated by restrictions in measurement time, especially in clinical settings. A central but difficult goal is thus, to maximize the diagnostic information that is collectable within a given time frame. This study demonstrates the practical applicability of the model-based experiment-steering procedure introduced in Herrmann and Dietz (2021, Acta Acustica, 5:51). The approach chooses the stimuli that are presented and estimates the model parameters best predicting the subject’s performance using a maximum-likelihood method. The same binaural tone-in-noise detection task was conducted using two measurement procedures: A standard adaptive staircase procedure and the model-based selection procedure based on an existing model. The model-steered procedure reached the same accuracy of model parameter estimation in on average only 42% of the time that was required with the standard adaptive procedure. Difficulties regarding the choice of a reliable model and reasonable discretization steps of its parameters are discussed. Although the physiological causes of an individual’s results cannot directly be inferred using this procedure, a characterization in terms of functional parameters is possible.


  • Open Access

    Longitudinal Observations of the Effects of Ischemic Stroke on Binaural Perception

    by Anna Dietze, Peter Soeroes, Henri Poentynen, Karsten Witt, Mathias Dietz

    Acute ischemic stroke, characterized by a localized reduction in blood flow to specific areas of the brain, has been shown to affect binaural auditory perception. In a previous study conducted during the acute phase of ischemic stroke, two tasks of binaural hearing were performed: binaural tone-in-noise detection, and lateralization of stimuli with interaural time- or level differences (Dietze et al., 2022, Front. Neurosci. 16:1022354). Various lesion-specific, as well as individual, differences in binaural performance between patients in the acute phase of stroke and a control group were demonstrated. For the current study, we re-invited the same group of patients, whereupon a subgroup repeated the experiments during the subacute and chronic phases of stroke. Similar to the initial study, this subgroup consisted of patients with lesions in different locations, including cortical and subcortical areas. At the group level, the results from the tone-in-noise detection experiment remained consistent across the three measurement phases, as did the number of deviations from normal performance in the lateralization task. However, the performance in the lateralization task exhibited variations over time among individual patients. Some patients demonstrated improvements in their lateralization abilities, indicating recovery, whereas others’ lateralization performance deteriorated during the later stages of stroke. Notably, our analyses did not reveal consistent patterns for patients with similar lesion locations. These findings suggest that recovery processes are more individual than the acute effects of stroke on binaural perception. Individual impairments in binaural hearing abilities after the acute phase of ischemic stroke have been demonstrated and should therefore also be targeted in rehabilitation programs.


  • Open Access

    Corrigendum: Effects of acute ischemic stroke on binaural perception

    by Anna Dietze, Peter Sörös, Matthias Bröer, Anna Methner, Henri Pöntynen, Benedikt Sundermann, Karsten Witt, Mathias Dietz

    Corrigendum: Effects of acute ischemic stroke on binaural perception


  • Open Access

    On the Effect of High Stimulation Rates on Temporal Loudness Integration in Cochlear Implant Users

    by Miguel Obando-Leitón, Anna Dietze, Carmen M. Castañeda González, Ali Saeedi, Sonja Karg, Werner Hemmert

    Long stimuli have lower detection thresholds or are perceived louder than short stimuli with the same intensity, an effect known as temporal loudness integration (TLI). In electric hearing, TLI for pulse trains with a fixed rate but varying number of pulses, i.e. stimulus duration, has mainly been investigated at clinically used stimulation rates. To study the effect of an overall effective stimulation rate at 100% channel crosstalk, we investigated TLI with (a) a clinically used single-channel stimulation rate of 1,500 pps and (b) a high stimulation rate of 18,000 pps, both for an apical and a basal electrode. Thresholds (THR), a line of equal loudness (BAL), and maximum acceptable levels (MALs) were measured in 10 MED-EL cochlear implant users. Stimulus durations varied from a single pulse to 300 ms long pulse trains. At 18,000 pps, the dynamic range (DR) increased by [ ] dB for the 300 ms pulse train. Amplitudes at THR, BAL, and MAL decreased monotonically with increasing stimulus duration. The decline was fitted with high accuracy with a power law function ([ ]). Threshold slopes were [ ] and [ ] dB per doubling of duration for the low and high rate, respectively, and were shallower than for acoustic hearing. The electrode location did not affect the amplitudes or slopes of the TLI curves. THR, BAL, and MAL were always lower for the higher rate and the DR was larger at the higher rate at all measured durations.


  • Open Access

    Effects of acute ischemic stroke on binaural perception

    by Anna Dietze, Peter Sörös, Matthias Bröer, Anna Methner, Henri Pöntynen, Benedikt Sundermann, Karsten Witt, Mathias Dietz

    Stroke-induced lesions at different locations in the brain can affect various aspects of binaural hearing, including spatial perception. Previous studies found impairments in binaural hearing, especially in patients with temporal lobe tumors or lesions, but also resulting from lesions all along the auditory pathway from brainstem nuclei up to the auditory cortex. Currently, structural magnetic resonance imaging (MRI) is used in the clinical treatment routine of stroke patients. In combination with structural imaging, an analysis of binaural hearing enables a better understanding of hearing-related signaling pathways and of clinical disorders of binaural processing after a stroke. However, little data are currently available on binaural hearing in stroke patients, particularly for the acute phase of stroke. Here, we sought to address this gap in an exploratory study of patients in the acute phase of ischemic stroke. We conducted psychoacoustic measurements using two tasks of binaural hearing: binaural tone-in-noise detection, and lateralization of stimuli with interaural time- or level differences. The location of the stroke lesion was established by previously acquired MRI data. An additional general assessment included three-frequency audiometry, cognitive assessments, and depression screening. Fifty-five patients participated in the experiments, on average 5 days after their stroke onset. Patients whose lesions were in different locations were tested, including lesions in brainstem areas, basal ganglia, thalamus, temporal lobe, and other cortical and subcortical areas. Lateralization impairments were found in most patients with lesions within the auditory pathway. Lesioned areas at brainstem levels led to distortions of lateralization in both hemifields, thalamus lesions were correlated with a shift of the whole auditory space, whereas some cortical lesions predominantly affected the lateralization of stimuli contralateral to the lesion and resulted in more variable responses. Lateralization performance was also found to be affected by lesions of the right, but not the left, basal ganglia, as well as by lesions in non-auditory cortical areas. In general, altered lateralization was common in the stroke group. In contrast, deficits in tone-in-noise detection were relatively scarce in our sample of lesion patients, although a significant number of patients with multiple lesion sites were not able to complete the task.