Xuan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuan Yu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bin Lu
Department of Anesthesiology, Zigong Fourth People’s Hospital, Zigong, China
3 shared publications Guo Mu
Department of Anesthesiology, Zigong Fourth People’s Hospital, Zigong, China
2 shared publicationsQiang Li
Department of Anesthesiology, Zigong Fourth People's Hospital, Zigong, Sichuan, 643000, China
2 shared publicationsFeixiang Wang
Anesthesiology and Critical Care Medicine Key Laboratory of Luzhou, Southwest Medical University, Luzhou, China
1 shared publication- Guo Mu
Department of Anesthesiology, Zigong Fourth People’s Hospital, Zigong, China
1 shared publication - Qiang Li
Department of Anesthesiology, Zigong Fourth People’s Hospital, Zigong, China
1 shared publication
Latest Publications
- Open Access
- 25 November 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1468310
Reevaluating 30 cmH2O endotracheal tube cuff pressure: risks of airway mucosal damage during prolonged mechanical ventilation
Background: The optimal endotracheal tube (ETT) cuff pressure remains contentious. In the traditional consideration that the level 30 cmH2O is considered safe, balancing the prevention of reflux aspiration against airway mucosal damage. Whether this pressure level can cause potential damage to the airway mucosa remains to be discussed.Methods: Airway mucosa damage and structural changes at 30 cmH2O were examined in patients under general anesthesia and in rabbit mechanical ventilation models. Prior to this, we also interviewed some anesthesiologists about the level of concern about ETT cuff pressure.Results: A total of 634 valid questionnaires suggested that anesthesiologists generally do not pay enough attention to ETT cuff pressure and the average established cuff pressure significantly exceeded 30 cmH2O. Airway mucosa images of 100 general anesthesia patients with different ventilation duration indicated that maintaining the pressure at 30 cmH2O did not cause significant damage to airway mucosa in a short period of time, while it still caused damage to airway mucosa in patients with long-term ventilation, with damage severity increasing with longer ventilation periods. This correlated strongly with postoperative sore throat (R2 = 0.3884, p < 0.001). In rabbits, 4 h of ventilation at this pressure resulted in significant loss of ciliated epithelium and inflammation. Calculations suggested an effective dose (ED50) to prevent mucosal injury at a cuff pressure of 25.64 cmH2O (95% CI: 19.268–29.367 cmH2O).Conclusion: The currently established cuff pressure of 30 cmH2O is associated with airway mucosal damage in both clinical and animal models. Lowering the safety threshold of cuff pressure may be necessary to mitigate mucosal injury.
- 25 November 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1468310
Open AccessReevaluating 30 cmH2O endotracheal tube cuff pressure: risks of airway mucosal damage during prolonged mechanical ventilation
Background: The optimal endotracheal tube (ETT) cuff pressure remains contentious. In the traditional consideration that the level 30 cmH2O is considered safe, balancing the prevention of reflux aspiration against airway mucosal damage. Whether this pressure level can cause potential damage to the airway mucosa remains to be discussed.Methods: Airway mucosa damage and structural changes at 30 cmH2O were examined in patients under general anesthesia and in rabbit mechanical ventilation models. Prior to this, we also interviewed some anesthesiologists about the level of concern about ETT cuff pressure.Results: A total of 634 valid questionnaires suggested that anesthesiologists generally do not pay enough attention to ETT cuff pressure and the average established cuff pressure significantly exceeded 30 cmH2O. Airway mucosa images of 100 general anesthesia patients with different ventilation duration indicated that maintaining the pressure at 30 cmH2O did not cause significant damage to airway mucosa in a short period of time, while it still caused damage to airway mucosa in patients with long-term ventilation, with damage severity increasing with longer ventilation periods. This correlated strongly with postoperative sore throat (R2 = 0.3884, p < 0.001). In rabbits, 4 h of ventilation at this pressure resulted in significant loss of ciliated epithelium and inflammation. Calculations suggested an effective dose (ED50) to prevent mucosal injury at a cuff pressure of 25.64 cmH2O (95% CI: 19.268–29.367 cmH2O).Conclusion: The currently established cuff pressure of 30 cmH2O is associated with airway mucosal damage in both clinical and animal models. Lowering the safety threshold of cuff pressure may be necessary to mitigate mucosal injury.
- 30 August 2024
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 224, 287-300
Hydrogen regulated pyroptosis through NLRP3-GSDMD pathway to improve airway mucosal oxidative stress injury induced by endotracheal tube cuff compression
- 30 August 2024
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 224, 287-300
Hydrogen regulated pyroptosis through NLRP3-GSDMD pathway to improve airway mucosal oxidative stress injury induced by endotracheal tube cuff compression
- 16 March 2023
- Published by Elsevier in International Immunopharmacology
- Vol. 117, 110033
Amelioration of nerve demyelination by hydrogen-producing silicon-based agent in neuropathic pain rats
- 16 March 2023
- Published by Elsevier in International Immunopharmacology
- Vol. 117, 110033
Amelioration of nerve demyelination by hydrogen-producing silicon-based agent in neuropathic pain rats