Yizhu Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yizhu Ren has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Lei Nie
Hubei University of Technology
2 shared publications - Mengying Tan
Key Lab of Modern Manufacture Quality Engineering, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Rouhui Wu
Hubei Modern Manufacturing Quality Laboratory, School of Mechanical Engineering, Hubei University of Technology, Wuhan 430068, China
2 shared publications
Latest Publications
- Open Access
Sensor Fault Diagnosis, Isolation, and Accommodation for Heating, Ventilating, and Air Conditioning Systems Based on Soft Sensor
Heating, Ventilating, and Air Conditioning (HVAC) systems often suffer from unscheduled maintenance or abnormal shutdown due to the fault of their interior sensor system. Traditional fault diagnosis methods for HVAC sensor systems primarily focus on sensor fault diagnosis and isolation, lacking fault accommodation. Therefore, to realize effective sensor fault detection, identification, and accommodation (SFDIA), a method for HVAC SFDIA based on the soft sensor is proposed. First, a diagnosis soft sensor with multi-variable input is constructed to estimate the output of the physical sensor being diagnosed. The residual between the estimated value of the diagnosis soft sensor and the measurement of the physical sensor is used as an indicator of the sensor’s condition. If the residual exceeds the fault threshold, the sensor is diagnosed to be faulty. In order to maintain valid sensor output, an accommodation soft sensor is constructed using the historical normal value. The erroneous output of the faulty sensor is substituted by the estimated value from the accommodation soft sensor, thereby realizing sensor fault tolerance control. Experimental results demonstrate that the average false alarm rate for sensor fault diagnosis is 1.57% and the average fault diagnosis rate is 96.51%. The predictive mean absolute error (MAE) and root-mean-square error (RMSE) of the recovered soft sensors are 0.0525 and 0.0738, respectively. Thus, the soft sensors developed in this paper exhibit satisfying ability in HVAC SFDIA.
Open AccessSensor Fault Diagnosis, Isolation, and Accommodation for Heating, Ventilating, and Air Conditioning Systems Based on Soft Sensor
Heating, Ventilating, and Air Conditioning (HVAC) systems often suffer from unscheduled maintenance or abnormal shutdown due to the fault of their interior sensor system. Traditional fault diagnosis methods for HVAC sensor systems primarily focus on sensor fault diagnosis and isolation, lacking fault accommodation. Therefore, to realize effective sensor fault detection, identification, and accommodation (SFDIA), a method for HVAC SFDIA based on the soft sensor is proposed. First, a diagnosis soft sensor with multi-variable input is constructed to estimate the output of the physical sensor being diagnosed. The residual between the estimated value of the diagnosis soft sensor and the measurement of the physical sensor is used as an indicator of the sensor’s condition. If the residual exceeds the fault threshold, the sensor is diagnosed to be faulty. In order to maintain valid sensor output, an accommodation soft sensor is constructed using the historical normal value. The erroneous output of the faulty sensor is substituted by the estimated value from the accommodation soft sensor, thereby realizing sensor fault tolerance control. Experimental results demonstrate that the average false alarm rate for sensor fault diagnosis is 1.57% and the average fault diagnosis rate is 96.51%. The predictive mean absolute error (MAE) and root-mean-square error (RMSE) of the recovered soft sensors are 0.0525 and 0.0738, respectively. Thus, the soft sensors developed in this paper exhibit satisfying ability in HVAC SFDIA.
- Open Access
Research on Fault Diagnosis of HVAC Systems Based on the ReliefF-RFECV-SVM Combined Model
A fault diagnosis method of heating, ventilation, and air conditioning (HVAC) systems based on the ReliefF-recursive feature elimination based on cross validation-support vector machine (ReliefF-RFECV-SVM) combined model is proposed to enhance the diagnosis accuracy and efficiency. The method initially uses ReliefF to screen the original features, selecting those that account for 95% of the total weight. The recursive feature elimination based on cross validation (RFECV), based on a random forest classifier, is then applied to select the optimal feature subset according to diagnostic accuracy. Finally, a support vector machine (SVM) model is constructed for fault classification. The method is tested on seven typical faults of the ASHRAE 1043-RP water chiller dataset and three typical faults of an air-cooled self-built air conditioner simulation dataset. The results show that the ReliefF-RFECV-SVM method significantly reduces diagnosis time compared to SVM, shortening it by about 50% based on the ASHRAE 1043-RP dataset, while achieving an overall accuracy of 99.98%. Moreover, the proposed method achieves a comprehensive diagnosis accuracy of 99.97% on the self-built simulation dataset, with diagnosis time the reduced by about 65% compared to single SVM.
Open AccessResearch on Fault Diagnosis of HVAC Systems Based on the ReliefF-RFECV-SVM Combined Model
A fault diagnosis method of heating, ventilation, and air conditioning (HVAC) systems based on the ReliefF-recursive feature elimination based on cross validation-support vector machine (ReliefF-RFECV-SVM) combined model is proposed to enhance the diagnosis accuracy and efficiency. The method initially uses ReliefF to screen the original features, selecting those that account for 95% of the total weight. The recursive feature elimination based on cross validation (RFECV), based on a random forest classifier, is then applied to select the optimal feature subset according to diagnostic accuracy. Finally, a support vector machine (SVM) model is constructed for fault classification. The method is tested on seven typical faults of the ASHRAE 1043-RP water chiller dataset and three typical faults of an air-cooled self-built air conditioner simulation dataset. The results show that the ReliefF-RFECV-SVM method significantly reduces diagnosis time compared to SVM, shortening it by about 50% based on the ASHRAE 1043-RP dataset, while achieving an overall accuracy of 99.98%. Moreover, the proposed method achieves a comprehensive diagnosis accuracy of 99.97% on the self-built simulation dataset, with diagnosis time the reduced by about 65% compared to single SVM.