Eivydas Andriukonis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eivydas Andriukonis has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andrius Vasiliauskas
Institute of Materials Science, Kaunas University of Technology, K. Baršausko 59, LT-51423 Kaunas, Lithuania
1 shared publication - Arunas Ramanavicius
Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko str. 24, LT-03225 Vilnius, Lithuania
1 shared publication - Arunas Stirke
Department of Functional Materials and Electronics, State research institute Center for Physical Sciences and Technology, Saulėtekio ave. 3, LT-10257 Vilnius, Lithuania
1 shared publication - Asta Guobienė
Kaunas University of Technology
1 shared publication - Marius Butkevicius
Department of Bioanalysis, Institute of Biochemistry, Life Sciences Centre, Vilnius University, Sauletekio av. 7, LT-10257 Vilnius, Lithuania
1 shared publication - Nerija Zurauskiene
Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257 Vilnius, Lithuania
1 shared publication
Latest Publications
- Open Access
- 18 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2373
Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO2/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 μg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 μg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics.
- 18 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2373
Open AccessBiosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2
Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO2/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 μg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 μg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics.
- Open Access
Development of a Disposable Polyacrylamide Hydrogel-Based Semipermeable Membrane for Micro Ag/AgCl Reference Electrode
Currently, Ag/AgCl-based reference electrodes are used in most electrochemical biosensors and other bioelectrochemical devices. However, standard reference electrodes are rather large and do not always fit within electrochemical cells designed for the determination of analytes in low-volume aliquots. Therefore, various designs and improvements in reference electrodes are critical for the future development of electrochemical biosensors and other bioelectrochemical devices. In this study, we explain a procedure to apply common laboratory polyacrylamide hydrogel in a semipermeable junction membrane between the Ag/AgCl reference electrode and the electrochemical cell. During this research, we have created disposable, easily scalable, and reproducible membranes suitable for the design of reference electrodes. Thus, we came up with castable semipermeable membranes for reference electrodes. Performed experiments highlighted the most suitable gel formation conditions to achieve optimal porosity. Here, Cl− ion diffusion through the designed polymeric junctions was evaluated. The designed reference electrode was also tested in a three-electrode flow system. The results show that home-built electrodes can compete with commercial products due to low reference electrode potential deviation (~3 mV), long shelf-life (up to six months), good stability, low cost, and disposability. The results show a high response rate, which makes in-house formed polyacrylamide gel junctions good membrane alternatives in the design of reference electrodes, especially for these applications where high-intensity dyes or toxic compounds are used and therefore disposable electrodes are required.
Open AccessDevelopment of a Disposable Polyacrylamide Hydrogel-Based Semipermeable Membrane for Micro Ag/AgCl Reference Electrode
Currently, Ag/AgCl-based reference electrodes are used in most electrochemical biosensors and other bioelectrochemical devices. However, standard reference electrodes are rather large and do not always fit within electrochemical cells designed for the determination of analytes in low-volume aliquots. Therefore, various designs and improvements in reference electrodes are critical for the future development of electrochemical biosensors and other bioelectrochemical devices. In this study, we explain a procedure to apply common laboratory polyacrylamide hydrogel in a semipermeable junction membrane between the Ag/AgCl reference electrode and the electrochemical cell. During this research, we have created disposable, easily scalable, and reproducible membranes suitable for the design of reference electrodes. Thus, we came up with castable semipermeable membranes for reference electrodes. Performed experiments highlighted the most suitable gel formation conditions to achieve optimal porosity. Here, Cl− ion diffusion through the designed polymeric junctions was evaluated. The designed reference electrode was also tested in a three-electrode flow system. The results show that home-built electrodes can compete with commercial products due to low reference electrode potential deviation (~3 mV), long shelf-life (up to six months), good stability, low cost, and disposability. The results show a high response rate, which makes in-house formed polyacrylamide gel junctions good membrane alternatives in the design of reference electrodes, especially for these applications where high-intensity dyes or toxic compounds are used and therefore disposable electrodes are required.