Rae A. Elkasabany
Research Subjects
Research Interests
Rae A. Elkasabany has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Edward Sisco
National Institute of Standards and Technology Gaithersburg Maryland USA
2 shared publications - Danielle Friedman Nestadt
Johns Hopkins Bloomberg School of Public Health
1 shared publication - Elise M. Pyfrom
National Institute of Standards and Technology Gaithersburg Maryland USA
1 shared publication - Kristin E. Schneider
Department of Health, Behavior, Society, Bloomberg School of Public Health, Johns Hopkins University, 624 N. Broadway, Baltimore, MD 21205, USA
1 shared publication - Madeline B. Bloom
George Washington University
1 shared publication - Meghan G. Appley
National Institute of Standards and Technology Gaithersburg Maryland USA
1 shared publication
Latest Publications
- Open Access
- 28 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Development of an Optimized Extraction Method to Recover Drug Material from Used Test Strips for Comprehensive Drug Checking
Drug checking programs use point-of-need testing (e.g., test strips) and laboratory-based analysis to rapidly identify emerging drug threats, but each have limitations. Test strips are quick but have high specificity, whereas laboratory testing can identify more compounds but have lengthy turnaround times. To address these limitations, it was proposed that compounds could be extracted from used test strips for additional analyses allowing for rapid onsite information followed by comprehensive laboratory results. The method development process involved four parts: determining the optimal extraction approach, assessing the feasibility of performing direct analysis in real time mass spectrometry (DART-MS) analysis on extracts, determining the limits of detection (LODs) for a range of analytes, and evaluating the method using used test strips submitted by harm reduction sites. The optimized method consisted of extracting analytes of interest from a cut test strip using 0.5 mL methanol while vortexing for 10 s. DART-MS successfully identified compounds of interests and successfully identified potential false positives from chemical background. LODs were found to be as low as a mass fraction of 0.005 in a mixture. For the samples submitted by harm reduction sites, concordance between extracts and test strip results was 96 % and the agreement in compound identification between used test strip extracts and authentic drug collection samples was approximately 80% regardless of test strip type and preparation. This work shows that additional analyses of extracted test strips can provide a low-barrier way for high-quality testing that can be used to increase data on the drug landscape.
- 28 November 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDevelopment of an Optimized Extraction Method to Recover Drug Material from Used Test Strips for Comprehensive Drug Checking
Drug checking programs use point-of-need testing (e.g., test strips) and laboratory-based analysis to rapidly identify emerging drug threats, but each have limitations. Test strips are quick but have high specificity, whereas laboratory testing can identify more compounds but have lengthy turnaround times. To address these limitations, it was proposed that compounds could be extracted from used test strips for additional analyses allowing for rapid onsite information followed by comprehensive laboratory results. The method development process involved four parts: determining the optimal extraction approach, assessing the feasibility of performing direct analysis in real time mass spectrometry (DART-MS) analysis on extracts, determining the limits of detection (LODs) for a range of analytes, and evaluating the method using used test strips submitted by harm reduction sites. The optimized method consisted of extracting analytes of interest from a cut test strip using 0.5 mL methanol while vortexing for 10 s. DART-MS successfully identified compounds of interests and successfully identified potential false positives from chemical background. LODs were found to be as low as a mass fraction of 0.005 in a mixture. For the samples submitted by harm reduction sites, concordance between extracts and test strip results was 96 % and the agreement in compound identification between used test strip extracts and authentic drug collection samples was approximately 80% regardless of test strip type and preparation. This work shows that additional analyses of extracted test strips can provide a low-barrier way for high-quality testing that can be used to increase data on the drug landscape.
- Open Access
- 15 June 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Understanding Sensitivity and Cross-Reactivity of Xylazine Lateral Flow Immunoassay Test Strips for Drug Checking Applications
The continued prevalence of xylazine in the illicit drug market has necessitated the development of quick and simple methods for identification of adulterated materials. One method that could be employed is lateral flow immunoassays (also known as test strips), which are similar to those frequently used to determine the presence of fentanyl. In this work, we explored the use of xylazine test strips (XTS) for the detection of xylazine in drug residue samples and investigated their sensitivity and cross-reactivity. XTS were found to detect xylazine at concentrations as low as 0.5 µg/mL in solution and consistently produced a positive result at concentrations as low as 2.5 µg/mL. Cross-reactivity with other α2-agonists, α2-antagonists, commonly encountered drugs and cutting agents, and other structurally similar compounds was minimal, with lidocaine being the only compound of the 77 studied to illicit a positive response. When XTS were used to detect xylazine in real-world drug residue samples, xylazine was consistently detected in samples where the concentration was above 2 µg/mL and mixed results were obtained when the concentration ranged between 0.1 µg/mL and 2 µg/mL. When considering samples that were negative for xylazine or had xylazine present at a concentration above the 1 µg/mL cut-off, an overall accuracy of 98.6% was achieved.
- 15 June 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessUnderstanding Sensitivity and Cross-Reactivity of Xylazine Lateral Flow Immunoassay Test Strips for Drug Checking Applications
The continued prevalence of xylazine in the illicit drug market has necessitated the development of quick and simple methods for identification of adulterated materials. One method that could be employed is lateral flow immunoassays (also known as test strips), which are similar to those frequently used to determine the presence of fentanyl. In this work, we explored the use of xylazine test strips (XTS) for the detection of xylazine in drug residue samples and investigated their sensitivity and cross-reactivity. XTS were found to detect xylazine at concentrations as low as 0.5 µg/mL in solution and consistently produced a positive result at concentrations as low as 2.5 µg/mL. Cross-reactivity with other α2-agonists, α2-antagonists, commonly encountered drugs and cutting agents, and other structurally similar compounds was minimal, with lidocaine being the only compound of the 77 studied to illicit a positive response. When XTS were used to detect xylazine in real-world drug residue samples, xylazine was consistently detected in samples where the concentration was above 2 µg/mL and mixed results were obtained when the concentration ranged between 0.1 µg/mL and 2 µg/mL. When considering samples that were negative for xylazine or had xylazine present at a concentration above the 1 µg/mL cut-off, an overall accuracy of 98.6% was achieved.