Francesco Tursi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Francesco Tursi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Aschieri
Cardiology Unit, Specialistic Medicine Department, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy
3 shared publications - Davide Imberti
Department of Internal Medicine, Piacenza Hospital, Via Taverna 49, 29121 Piacenza, Italy
3 shared publications - Esther Centenara
Department of Internal Medicine, Castel San Giovanni Hospital, Vle II Giugno, 1, 29015 Castel San Giovanni, Italy
3 shared publications - Francesco Giangregorio
Department of Internal Medicine, Castel San Giovanni Hospital, Vle II Giugno, 1, 29015 Castel San Giovanni, Italy
3 shared publications - Luigi Gerra
Cardiology Unit, Guglielmo da Saliceto Hospital, 29121 Piacenza, Italy
3 shared publications - Samanta Mazzocchi
Department of Internal Medicine, Castel San Giovanni Hospital, Vle II Giugno, 1, 29015 Castel San Giovanni, Italy
3 shared publications
Latest Publications
- Open Access
- 30 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1111
Assessing Venous Congestion in Heart Failure: A Review of Splanchnic, Cardiac, and Pulmonary Ultrasound: Part 2: Contrast-Enhanced Ultrasound and Shear Wave
Background: Heart failure (HF) is a systemic syndrome characterized by venous congestion, which critically involves the splanchnic circulation. Conventional assessment methods often lack sensitivity for early or regional congestion. Methods: We conducted a systematic review of studies utilizing contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) to evaluate congestion in adult HF patients, synthesizing evidence up to July 2025. Results: The integrated evidence demonstrates that CEUS and SWE provide distinct, complementary quantitative data. CEUS acts as a functional pillar, detecting microvascular congestion through parameters like prolonged hepatic vein transit time. SWE serves as a structural pillar, quantifying tissue stiffness that correlates with central venous pressure, tracks decongestion, and independently predicts adverse outcomes. Together, they differentiate reversible hemodynamic congestion from irreversible fibrotic remodeling across the liver, spleen, kidneys, and heart. Conclusions: Integrating CEUS and SWE into a multi-parametric ultrasound framework provides a comprehensive, bedside assessment of systemic congestion in HF. This approach enhances early detection, improves risk stratification, and offers a potential tool for guiding and monitoring personalized decongestive therapy, representing a significant advancement in holistic HF management.
- 30 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 1111
Open AccessAssessing Venous Congestion in Heart Failure: A Review of Splanchnic, Cardiac, and Pulmonary Ultrasound: Part 2: Contrast-Enhanced Ultrasound and Shear Wave
Background: Heart failure (HF) is a systemic syndrome characterized by venous congestion, which critically involves the splanchnic circulation. Conventional assessment methods often lack sensitivity for early or regional congestion. Methods: We conducted a systematic review of studies utilizing contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) to evaluate congestion in adult HF patients, synthesizing evidence up to July 2025. Results: The integrated evidence demonstrates that CEUS and SWE provide distinct, complementary quantitative data. CEUS acts as a functional pillar, detecting microvascular congestion through parameters like prolonged hepatic vein transit time. SWE serves as a structural pillar, quantifying tissue stiffness that correlates with central venous pressure, tracks decongestion, and independently predicts adverse outcomes. Together, they differentiate reversible hemodynamic congestion from irreversible fibrotic remodeling across the liver, spleen, kidneys, and heart. Conclusions: Integrating CEUS and SWE into a multi-parametric ultrasound framework provides a comprehensive, bedside assessment of systemic congestion in HF. This approach enhances early detection, improves risk stratification, and offers a potential tool for guiding and monitoring personalized decongestive therapy, representing a significant advancement in holistic HF management.
- Open Access
- 17 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8147
Assessing Venous Congestion in Acute and Chronic Heart Failure: A Review of Splanchnic, Cardiac and Pulmonary Ultrasound: Part 1: Conventional B-Mode, Colordoppler, and Vexus Protocol
Background/Objectives: Heart failure (HF) causes systemic and regional haemodynamic alterations that extend beyond the heart, profoundly affecting splanchnic circulation. Venous congestion is a hallmark of heart failure (HF) and a major determinant of clinical deterioration and multiorgan dysfunction. The splanchnic venous system—comprising the portal, hepatic, and renal veins—acts as a key reservoir for intravascular volume redistribution. Conventional ultrasound (US), using grayscale and Doppler imaging, offers a direct, non-invasive approach to visualize these haemodynamic changes. This review, Part 1 of a two-part series, summarizes the current evidence and clinical applications of conventional US for assessing splanchnic, cardiac and pulmonary vascular alterations in patients with HF. Methods: A systematic review was performed in PubMed, Embase, and the Cochrane Library up to current date, following PRISMA 2020 guidelines. Eligible studies included adult human investigations evaluating splanchnic vascular changes in HF using B-mode, color Doppler, or pulsed Doppler ultrasonography. Exclusion criteria were pediatric, animal, or non-English studies and non-standard imaging methods. Data on ultrasonographic parameters, haemodynamic correlations, and prognostic value were extracted and qualitatively synthesized; Results: A total of 148 eligible studies (n ≈ 7000 patients) demonstrated consistent associations between HF severity and alterations in splanchnic, cardiac and pulmonary flow. Findings included increased bowel wall thickness, portal vein dilation with elevated pulsatility, and monophasic or reversed hepatic vein waveforms, all correlating with higher right atrial pressure and adverse clinical outcomes. The integration of these parameters into the Venous Excess Ultrasound (VExUS) framework enhanced detection of systemic venous congestion, in addition to the study of the cardiac and pulmonary circulation. Conclusions: Conventional ultrasound assessment of splanchnic vasculature provides valuable, reproducible insight into systemic congestion in HF. Incorporating hepatic and portal Doppler indices into standard evaluation protocols may improve risk stratification, optimize decongestion therapy, and guide management. Further prospective randomized and outcome-driven studies are required before VExUS-based therapeutic thresholds can be universally recommended and define prognostic thresholds.
- 17 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8147
Open AccessAssessing Venous Congestion in Acute and Chronic Heart Failure: A Review of Splanchnic, Cardiac and Pulmonary Ultrasound: Part 1: Conventional B-Mode, Colordoppler, and Vexus Protocol
Background/Objectives: Heart failure (HF) causes systemic and regional haemodynamic alterations that extend beyond the heart, profoundly affecting splanchnic circulation. Venous congestion is a hallmark of heart failure (HF) and a major determinant of clinical deterioration and multiorgan dysfunction. The splanchnic venous system—comprising the portal, hepatic, and renal veins—acts as a key reservoir for intravascular volume redistribution. Conventional ultrasound (US), using grayscale and Doppler imaging, offers a direct, non-invasive approach to visualize these haemodynamic changes. This review, Part 1 of a two-part series, summarizes the current evidence and clinical applications of conventional US for assessing splanchnic, cardiac and pulmonary vascular alterations in patients with HF. Methods: A systematic review was performed in PubMed, Embase, and the Cochrane Library up to current date, following PRISMA 2020 guidelines. Eligible studies included adult human investigations evaluating splanchnic vascular changes in HF using B-mode, color Doppler, or pulsed Doppler ultrasonography. Exclusion criteria were pediatric, animal, or non-English studies and non-standard imaging methods. Data on ultrasonographic parameters, haemodynamic correlations, and prognostic value were extracted and qualitatively synthesized; Results: A total of 148 eligible studies (n ≈ 7000 patients) demonstrated consistent associations between HF severity and alterations in splanchnic, cardiac and pulmonary flow. Findings included increased bowel wall thickness, portal vein dilation with elevated pulsatility, and monophasic or reversed hepatic vein waveforms, all correlating with higher right atrial pressure and adverse clinical outcomes. The integration of these parameters into the Venous Excess Ultrasound (VExUS) framework enhanced detection of systemic venous congestion, in addition to the study of the cardiac and pulmonary circulation. Conclusions: Conventional ultrasound assessment of splanchnic vasculature provides valuable, reproducible insight into systemic congestion in HF. Incorporating hepatic and portal Doppler indices into standard evaluation protocols may improve risk stratification, optimize decongestion therapy, and guide management. Further prospective randomized and outcome-driven studies are required before VExUS-based therapeutic thresholds can be universally recommended and define prognostic thresholds.
- Open Access
- 14 October 2025
- Published by MDPI AG in Preprints.org
Assessing Venous Congestion in Acute and Chronic Heart Failure: A Review of Splanchnic, Cardiac and Pulmonary Ultrasound: Part 1: Conventional B-Mode, Colordoppler, and Vexus Protocol
Background and Objectives: Heart failure (HF) causes systemic and regional hemodynamic alterations that extend beyond the heart, profoundly affecting splanchnic circulation. Venous congestion in the hepatic and portal systems is a key but often underrecognized determinant of organ dysfunction and symptom burden. Conventional ultrasound and Doppler techniques offer a non-invasive, dynamic evaluation of these changes, potentially complementing standard echocardiographic and biomarker assessments. Materials and Methods: A systematic review was performed in PubMed, Embase, and the Cochrane Library up to July 2025, following PRISMA 2020 guidelines. Eligible studies included adult human investigations evaluating splanchnic vascular changes in HF using B-mode, color Doppler, or pulsed Doppler ultrasonography. Exclusion criteria were pediatric, animal, or non-English studies and non-standard imaging methods. Data on ultrasonographic parameters, hemodynamic correlations, and prognostic value were extracted and qualitatively synthesized; sympathetic nervous system; heart failure with preserved ejection fraction; ultrasound; b-mode, colordoppler, pulsed doppler. Results: A total of 148 eligible studies (n ≈ 7,000 patients) demonstrated consistent associations between HF severity and alterations in splanchnic flow. Findings included increased bowel wall thickness, portal vein dilation with elevated pulsatility, and monophasic or reversed hepatic vein waveforms, all correlating with higher right atrial pressure and adverse clinical outcomes. The integration of these parameters into the Venous Excess Ultrasound (VExUS) framework enhanced detection of systemic venous congestion. Conclusions: Conventional ultrasound assessment of splanchnic vasculature provides valuable, reproducible insight into systemic congestion in HF. Incorporating hepatic and portal Doppler indices into standard evaluation protocols may improve risk stratification, optimize decongestion therapy, and guide management. Further prospective validation is warranted to standardize cutoff values and define prognostic thresholds.
- 14 October 2025
- Published by MDPI AG in Preprints.org
Open AccessAssessing Venous Congestion in Acute and Chronic Heart Failure: A Review of Splanchnic, Cardiac and Pulmonary Ultrasound: Part 1: Conventional B-Mode, Colordoppler, and Vexus Protocol
Background and Objectives: Heart failure (HF) causes systemic and regional hemodynamic alterations that extend beyond the heart, profoundly affecting splanchnic circulation. Venous congestion in the hepatic and portal systems is a key but often underrecognized determinant of organ dysfunction and symptom burden. Conventional ultrasound and Doppler techniques offer a non-invasive, dynamic evaluation of these changes, potentially complementing standard echocardiographic and biomarker assessments. Materials and Methods: A systematic review was performed in PubMed, Embase, and the Cochrane Library up to July 2025, following PRISMA 2020 guidelines. Eligible studies included adult human investigations evaluating splanchnic vascular changes in HF using B-mode, color Doppler, or pulsed Doppler ultrasonography. Exclusion criteria were pediatric, animal, or non-English studies and non-standard imaging methods. Data on ultrasonographic parameters, hemodynamic correlations, and prognostic value were extracted and qualitatively synthesized; sympathetic nervous system; heart failure with preserved ejection fraction; ultrasound; b-mode, colordoppler, pulsed doppler. Results: A total of 148 eligible studies (n ≈ 7,000 patients) demonstrated consistent associations between HF severity and alterations in splanchnic flow. Findings included increased bowel wall thickness, portal vein dilation with elevated pulsatility, and monophasic or reversed hepatic vein waveforms, all correlating with higher right atrial pressure and adverse clinical outcomes. The integration of these parameters into the Venous Excess Ultrasound (VExUS) framework enhanced detection of systemic venous congestion. Conclusions: Conventional ultrasound assessment of splanchnic vasculature provides valuable, reproducible insight into systemic congestion in HF. Incorporating hepatic and portal Doppler indices into standard evaluation protocols may improve risk stratification, optimize decongestion therapy, and guide management. Further prospective validation is warranted to standardize cutoff values and define prognostic thresholds.
- Open Access
- 23 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 411
Ultrasonographic Assessment of Diaphragmatic Function and Its Clinical Application in the Management of Patients with Acute Respiratory Failure
Acute respiratory failure (ARF) is a common life-threatening medical condition, with multiple underlying etiologies. In these cases, many factors related to systemic inflammation, prolonged use of steroids, and lung mechanical abnormalities (such as hyperinflation or increased elastic recoil due to pulmonary oedema or fibrosis) may act as synergic mechanisms leading to diaphragm dysfunction. The assessment of diaphragm function with ultrasound has been increasingly investigated in the emergency department and during hospital stay as a valuable tool for providing additional anatomical and functional information in many acute respiratory diseases. The diaphragmatic ultrasound is a noninvasive and repeatable bedside tool, has no contraindications, and allows the physician to rapidly assess the presence of diaphragmatic dysfunction; this evaluation may help in estimating the need for mechanical ventilation (and the risk of weaning failure), as well as the risk of longer hospital stay and higher mortality rate. This study presents an overview of the recent evidence regarding the evaluation of diaphragmatic function with bedside ultrasound and its clinical applications, including a discussion of real-life clinical cases.
- 23 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 411
Open AccessUltrasonographic Assessment of Diaphragmatic Function and Its Clinical Application in the Management of Patients with Acute Respiratory Failure
Acute respiratory failure (ARF) is a common life-threatening medical condition, with multiple underlying etiologies. In these cases, many factors related to systemic inflammation, prolonged use of steroids, and lung mechanical abnormalities (such as hyperinflation or increased elastic recoil due to pulmonary oedema or fibrosis) may act as synergic mechanisms leading to diaphragm dysfunction. The assessment of diaphragm function with ultrasound has been increasingly investigated in the emergency department and during hospital stay as a valuable tool for providing additional anatomical and functional information in many acute respiratory diseases. The diaphragmatic ultrasound is a noninvasive and repeatable bedside tool, has no contraindications, and allows the physician to rapidly assess the presence of diaphragmatic dysfunction; this evaluation may help in estimating the need for mechanical ventilation (and the risk of weaning failure), as well as the risk of longer hospital stay and higher mortality rate. This study presents an overview of the recent evidence regarding the evaluation of diaphragmatic function with bedside ultrasound and its clinical applications, including a discussion of real-life clinical cases.