Hesheng Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hesheng Yin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Junlong Guo
Harbin Institute of Technology
2 shared publications - Yufeng Yao
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Jiajia Wang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
1 shared publication - Shuo Pei
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
1 shared publication - Yunlong Yang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
1 shared publication
Latest Publications
- Open Access
A Human-like Inverse Kinematics Algorithm of an Upper Limb Rehabilitation Exoskeleton
Powered exoskeleton rehabilitation is an effective way to help stroke patients recover their motor abilities. Bionic structures and human-like control strategies can be used to enhance both the safety and efficacy of exoskeletons. However, the motion characteristics of the shoulder complex are not sufficiently considered. In this paper, we designed a 7-degrees-of-freedom (DOF) upper limb rehabilitation exoskeleton, FREE (functional rehabilitation exoskeleton). The mechanical structures of the shoulder and forearm of FREE are in accordance with human anatomy, and can be used to perform a wide range of synergistic motion of multiple joints while keeping a safe distance from the patient’s head. A multiple-input-multiple-output (MIMO) shoulder girdle motion prediction model was developed to satisfy the synergy between humans and exoskeletons. Moreover, a constrained task priority and projected gradient-based inverse kinematics algorithm (CTPPG-IK) was proposed to achieve assistance with scapulohumeral rhythm. A motion capture system was used to collect different activities of daily life (ADL) motion data to validate the proposed algorithm. The experimental results show that the accuracy of the prediction model is higher than that of existing models, and the inverse kinematics algorithm can handle the end-effector task and joint space with a maximum angle error of rad.Open AccessA Human-like Inverse Kinematics Algorithm of an Upper Limb Rehabilitation Exoskeleton
Powered exoskeleton rehabilitation is an effective way to help stroke patients recover their motor abilities. Bionic structures and human-like control strategies can be used to enhance both the safety and efficacy of exoskeletons. However, the motion characteristics of the shoulder complex are not sufficiently considered. In this paper, we designed a 7-degrees-of-freedom (DOF) upper limb rehabilitation exoskeleton, FREE (functional rehabilitation exoskeleton). The mechanical structures of the shoulder and forearm of FREE are in accordance with human anatomy, and can be used to perform a wide range of synergistic motion of multiple joints while keeping a safe distance from the patient’s head. A multiple-input-multiple-output (MIMO) shoulder girdle motion prediction model was developed to satisfy the synergy between humans and exoskeletons. Moreover, a constrained task priority and projected gradient-based inverse kinematics algorithm (CTPPG-IK) was proposed to achieve assistance with scapulohumeral rhythm. A motion capture system was used to collect different activities of daily life (ADL) motion data to validate the proposed algorithm. The experimental results show that the accuracy of the prediction model is higher than that of existing models, and the inverse kinematics algorithm can handle the end-effector task and joint space with a maximum angle error of rad. - Open Access
- 14 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (16) , 3436
Development of a Compliant Lower-Limb Rehabilitation Robot Using Underactuated Mechanism
Most existing lower-limb rehabilitation robots (LLRR) for stroke and postoperative rehabilitation are bulky and prone to misalignments between robot and human joints. These drawbacks hamper LLRR application, leading to poor arthro-kinematic compatibility. To address these challenges, this paper proposes a novel robot with portability and compliance features. The developed robot consists of an underactuated mechanism and a crus linkage, respectively corresponding to the hip and knee joints. The underactuated mechanism is a new type of remote center of motion (RCM) mechanism with two sets of contractible slider cranks that can reduce the misalignments between robot and human joints. The underactuated mechanism is then optimized using the particle swarm optimization method, and the developed robot’s kinematic analysis is presented. The proposed robot can be simplified as a two-link mechanism with the ability to easily plan its trajectory using the modified Denavit–Hartenberg method. Finally, passive exercise trials demonstrate that the mismatch angles between the human and robot knee joints are less than 2.1% of the range of motion, confirming the feasibility and effectiveness of the proposed robot.
- 14 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (16) , 3436
Open AccessDevelopment of a Compliant Lower-Limb Rehabilitation Robot Using Underactuated Mechanism
Most existing lower-limb rehabilitation robots (LLRR) for stroke and postoperative rehabilitation are bulky and prone to misalignments between robot and human joints. These drawbacks hamper LLRR application, leading to poor arthro-kinematic compatibility. To address these challenges, this paper proposes a novel robot with portability and compliance features. The developed robot consists of an underactuated mechanism and a crus linkage, respectively corresponding to the hip and knee joints. The underactuated mechanism is a new type of remote center of motion (RCM) mechanism with two sets of contractible slider cranks that can reduce the misalignments between robot and human joints. The underactuated mechanism is then optimized using the particle swarm optimization method, and the developed robot’s kinematic analysis is presented. The proposed robot can be simplified as a two-link mechanism with the ability to easily plan its trajectory using the modified Denavit–Hartenberg method. Finally, passive exercise trials demonstrate that the mismatch angles between the human and robot knee joints are less than 2.1% of the range of motion, confirming the feasibility and effectiveness of the proposed robot.