Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Valérie Chénard has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Physicochemical Stability Study of Pembrolizumab Vial Leftovers: Let Us Stop Pouring Good Money Down the Drain

    by Alexandra Porlier, Pierre-Yves Gagnon, Valérie Chénard, Marc Veillette, Nicolas Bertrand, Caroline Duchaine, Chantale Simard, Benoît Drolet

    Background: Pembrolizumab is a monoclonal antibody (mAb) approved for treating Non-Small Cell Lung Cancer (NSCLC), melanoma and lymphomas. Commercialized in single-size (100 mg/4 mL) vials, the pembrolizumab solution contains no preservative. As such, the manufacturer recommends using pembrolizumab vials only once, and thus, to rapidly dispose of any unused portion. Thus, appreciable amounts of this costly product are wasted. Objective: To evaluate the physical, chemical and microbiological stability of pembrolizumab vial leftovers stored at room temperature or at 4 °C, 7 and 14 days after first vial puncturing. Methods: Following pH assessments, submicronic aggregation and turbidity of pembrolizumab were measured by dynamic light scattering (DLS) and spectrophotometry, respectively. In addition, SE-HPLC (size-exclusion high-performance liquid chromatography), IEX-HPLC (ion exchange HPLC) and peptide mapping HPLC served to respectively evaluate aggregation and fragmentation, distribution of charge and primary structure of pembrolizumab. Incubation at 37 °C for 48 h of pembrolizumab vial leftovers on blood agar plates was used to determine their microbiological stability. Results: Physical, chemical and microbiological stability of pembrolizumab leftovers was demonstrated for at least two full weeks. Conclusions: These results argue forcefully in favor of allowing prolongation of pembrolizumab vial leftovers usage well beyond a single day.


  • Open Access

    Dual-Labelled Nanoparticles Inform on the Stability of Fluorescent Labels In Vivo

    by Sabrina Roussel, Philippe Grenier, Valérie Chénard, Nicolas Bertrand

    Fluorescent labelling is commonly used to monitor the biodistribution of nanomedicines. However, meaningful interpretation of the results requires that the fluorescent label remains attached to the nanomedicine. In this work, we explore the stability of three fluorophores (BODIPY650, Cyanine 5 and AZ647) attached to polymeric hydrophobic biodegradable anchors. Using dual-labelled poly(ethylene glycol)-b-poly(lactic acid) (PEG-PLA) nanoparticles that are both radioactive and fluorescent, we investigated how the properties of the fluorophores impact the stability of the labelling in vitro and in vivo. Results suggest that the more hydrophilic dye (AZ647) is released faster from nanoparticles, and that this instability results in misinterpretation of in vivo data. While hydrophobic dyes are likely more suitable to track nanoparticles in biological environments, quenching of the fluorescence inside the nanoparticles can also introduce artefacts. Altogether, this work raises awareness about the importance of stable labelling methods when investigating the biological fate of nanomedicines.