DMDidacienne Mukalinyigira

Didacienne Mukalinyigira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Didacienne Mukalinyigira has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Internet of Things-Based Electromagnetic Compatibility Monitoring (IEMCM) Architecture for Biomedical Devices

    by Chiedza Hwata, Gerard Rushingabigwi, Omar Gatera, Didacienne Mukalinyigira, Celestin Twizere, Bolaji N. Thomas, Diego H. Peluffo-Ord’onez

    Electromagnetic compatibility is the capability of electrical and electronic equipment to function properly around devices radiating electromagnetic energy, without mutual disturbance. Hospital environments contain numerous devices operating simultaneously and sharing resources. Undetected electromagnetic interference can cause medical devices’ malfunctions, exposing patients and staff. Traditional monitoring is time-consuming and relies on expert interpretation. An Internet of Things-enabled embedded system architecture for remote and real-time monitoring of electromagnetic fields from medical devices is proposed. It integrates frequency probes, a Raspberry Pi 4, and a communication module. A three-month study conducted at Muhima District Hospital, Kigali, Rwanda, demonstrated the system’s effectiveness in monitoring electromagnetic field levels and cloud transmission. The signals were benchmarked against International Electrotechnical Commission and Rwanda Standards Board standards. Alerts are triggered when thresholds are exceeded, with results plotted on website and mobile interfaces. Emissions were highest at noon when the equipment was most active and lower after 1:30 PM, indicating reduced activity. The sample recorded statistics of electric fields include mean (1.0028), minimum (0.7228), and maximum (1.3515). Among the five filters evaluated, the Savitzky–Golay performed better, with MSE (0.235) and SNR (9.308). A 412 ms average latency and 24 h operation was achieved, offering a portable solution for hospital safety and equipment optimization.


  • Open Access

    Evaluation of the awareness of electromagnetic compatibility and interference for improved medical device management observed in selected Rwanda district hospitals

    by Chiedza Mtech Hwata, Omar Gatera, Nicola Ritsch, Therese Meng Uwiragiye, Gerard Rushingabigwi, Celestin Twizere, Didacienne Mukalinyigira, Bolaji Thomas, Daniel Msc Nsengiyera

    Accuracy and reliability of medical device measurements are essential for high-quality healthcare delivery. Electromagnetic compatibility (EMC) is 1 of the conditions that can be monitored when managing electronic and wireless medical devices in hospitals. Noncompliance with EMC can lead to electromagnetic interference (EMI), risking catastrophic failures, especially in vital sign devices such as defibrillators and pacemakers, and potentially irreversible harm to patients’ health. This study assessed the knowledge of biomedical engineers and technicians regarding EMC and EMI in hospital devices and their effects. It also examines how hospitals manage biomedical equipment and the frequency of wireless communication usage. This study utilized an anonymous questionnaire administered to 35 biomedical personnel in Rwanda district hospitals. Face-to-face interviews were used for data collection. SPSS was used to analyze the data through descriptive analyses statistically, and a regression model was designed to evaluate the impact of electromagnetic compatibility and interference on medical device management (MDM). A statistical significance of 0.05 was assumed. The regression model predicted MDM with a significance level of 0.009 based on ANOVA values. A Pearson’s correlation test was also performed for the model. The results indicated an inverse relationship of −0.470 for EMI against MDM and −0.469 for EMC against MDM. A total of 24 (68.6%) respondents were unaware of electromagnetic compatibility/interference issues and 11 (31.4%) were familiar with it. All 35 respondents indicated that maintenance is currently being performed on medical devices. High usage of wireless devices, for professional and personal purposes is highlighted. Based on the results, both electromagnetic compatibility and understanding of interference influenced MDM. To ensure optimal medical device performance and improve hospital safety, we recommend continuous monitoring of medical device electromagnetic compatibility. Additionally, EMC/EMI awareness training can be incorporated into on-the-job training programs for biomedical staff members.


  • Open Access

    Battery-Powered RSU Running Time Monitoring and Prediction Using ML Model Based on Received Signal Strength and Data Transmission Frequency in V2I Applications

    by Vienna N. Katambire, Richard Musabe, Alfred Uwitonze, Didacienne Mukanyiligira

    The application of the Internet of Things (IoT), vehicles to infrastructure (V2I) communication and intelligent roadside units (RSU) are promising paradigms to improve road traffic safety. However, for the RSUs to communicate with the vehicles and transmit the data to the remote location, RSUs require enough power and good network quality. Recent advances in technology have improved lithium-ion battery capabilities. However, other complementary methodologies including battery management systems (BMS) have to be developed to provide an early warning sign of the battery’s state of health. In this paper, we have evaluated the impact of the received signal strength indication (RSSI) and the current consumption at different transmission frequencies on a static battery-based RSU that depends on the global system for mobile communications (GSM)/general packet radio services (GPRS). Machine learning (ML) models, for instance, Random Forest (RF) and Support Vector Machine (SVM), were employed and tested on the collected data and later compared using the coefficient of determination (R2). The models were used to predict the battery current consumption based on the RSSI of the location where the RSUs were imposed and the frequency at which the RSU transmits the data to the remote database. The RF was preferable to SVM for predicting current consumption with an R2 of 98% and 94%, respectively. It is essential to accurately forecast the battery health of RSUs to assess their dependability and running time. The primary duty of the BMS is to estimate the status of the battery and its dynamic operating limits. However, achieving an accurate and robust battery state of charge remains a significant challenge. Referring to that can help road managers make alternative decisions, such as replacing the battery before the RSU power source gets drained. The proposed method can be deployed in other remote WSN and IoT-based applications.