Wolfgang J. Mayer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wolfgang J. Mayer has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Siegfried Georg Priglinger
Department of Ophthalmology, University Hospital, LMU Munich, Mathildenstrasse 8, 80336 Munich, Germany
2 shared publications - Thomas Christian Kreutzer
Department of Ophthalmology, University Hospital, LMU Munich, 80336 Munich, Germany
2 shared publications - Benedikt Schworm
Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-University, 80539 Munich, Germany
1 shared publication - Denise Vogt
Retina Vitreous Research Group, Department of Ophthalmology, University Hospital Ulm, Ulm, Germany
1 shared publication - Elisa Vanessa Osterode
Department of Ophthalmology, LMU University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
1 shared publication - Felix Hagenau
Department of Ophthalmology, Ludwig-Maximilians-University, 80336 Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 14 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (22) , 6861
Comparison of Refractive Outcomes After Phacoemulsification and Combined 25-Gauge Phacovitrectomy with Implantation of Plate-Haptic Toric Intraocular Lenses
Objectives: To compare intraocular lens (IOL) position and refractive outcomes between eyes that underwent sole phacoemulsification with those that underwent combined 25-gauge phacovitrectomy with a plate-haptic toric IOL implantation. Methods: This retrospective study included 60 eyes of 60 patients. Of these, 30 eyes underwent 25-gauge phacovitrectomy, while the other 30 eyes received phacoemulsification alone. In both groups, a plate-haptic toric intraocular lens (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted. The main outcome measures were the refractive outcome, the refraction prediction error (PE), the difference in the postoperative anatomical lens position (ALP) change, and rotational stability. Results: The mean spherical equivalent decreased considerably from −2 ± 4.4 diopters (D) to −0.6 ± 1.4 D after phacovitrectomy (p = 0.05) and −0.7 D ± 5.5 D to −0.1 ± 1.1 D after phacoemulsification (p = 0.5). The prediction error (PE) was comparable between the two groups for all formulas (Haigis-T: p = 0.8, Barrett TK Toric: p = 0.8, Z CALC: p = 0.7). No significant difference in absolute ALP change and postoperative rotational stability was observed between the phacovitrectomy and phacoemulsification group (1.4 mm vs. 1.4 mm, p = 0.96; 2.9° vs. 2.1°, p = 0.5). Conclusions: The implantation of plate-haptic toric IOLs in the combined phacovitrectomy group resulted in refraction and IOL positioning outcomes comparable to those in the phacoemulsification-only group.
- 14 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (22) , 6861
Open AccessComparison of Refractive Outcomes After Phacoemulsification and Combined 25-Gauge Phacovitrectomy with Implantation of Plate-Haptic Toric Intraocular Lenses
Objectives: To compare intraocular lens (IOL) position and refractive outcomes between eyes that underwent sole phacoemulsification with those that underwent combined 25-gauge phacovitrectomy with a plate-haptic toric IOL implantation. Methods: This retrospective study included 60 eyes of 60 patients. Of these, 30 eyes underwent 25-gauge phacovitrectomy, while the other 30 eyes received phacoemulsification alone. In both groups, a plate-haptic toric intraocular lens (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted. The main outcome measures were the refractive outcome, the refraction prediction error (PE), the difference in the postoperative anatomical lens position (ALP) change, and rotational stability. Results: The mean spherical equivalent decreased considerably from −2 ± 4.4 diopters (D) to −0.6 ± 1.4 D after phacovitrectomy (p = 0.05) and −0.7 D ± 5.5 D to −0.1 ± 1.1 D after phacoemulsification (p = 0.5). The prediction error (PE) was comparable between the two groups for all formulas (Haigis-T: p = 0.8, Barrett TK Toric: p = 0.8, Z CALC: p = 0.7). No significant difference in absolute ALP change and postoperative rotational stability was observed between the phacovitrectomy and phacoemulsification group (1.4 mm vs. 1.4 mm, p = 0.96; 2.9° vs. 2.1°, p = 0.5). Conclusions: The implantation of plate-haptic toric IOLs in the combined phacovitrectomy group resulted in refraction and IOL positioning outcomes comparable to those in the phacoemulsification-only group.
- Open Access
- 27 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (5) , 4589
Long-Term Results of Adjunct Autologous Platelet-Rich Plasma in Lamellar Macular Hole Surgery Showing Lasting Restoration of Foveal Anatomy
The aim of this study was to evaluate the long-time results of highly concentrated autologous platelet-rich plasma (PRP) used as an adjunct in lamellar macular hole (LMH) surgery. Nineteen eyes of nineteen patients with progressive LMH were enrolled in this interventional case series, on which 23/25-gauge pars plana vitrectomy was performed and 0.1 mL of highly concentrated autologous platelet-rich plasma was applied under air tamponade. Posterior vitreous detachment was induced, and the peeling of tractive epiretinal membranes, whenever present, was performed. In cases of phakic lens status, combined surgery was carried out. Postoperatively, all patients were instructed to remain in a supine position for the first two postoperative hours. Best-corrected visual acuity (BCVA) testing, microperimetry, and spectral domain optical coherence tomography (SD-OCT) were carried out preoperatively and at minimum 6 months (in median 12 months) postoperatively. Foveal configuration was postoperatively restored in 19 of 19 patients. Two patients who had not undergone ILM peeling showed a recurring defect at 6-month follow-up. Best-corrected visual acuity improved significantly from 0.29 ± 0.08 to 0.14 ± 0.13 logMAR (p = 0.028, Wilcoxon signed-rank test). Microperimetry remained unchanged (23.38 ± 2.53 preoperatively; 23.0 ± 2.49 dB postoperatively; p = 0.67). No patients experienced vision loss after surgery, and no significant intra- or postoperative complications were observed. Using PRP as an adjunct in macular hole surgery significantly improves morphological and functional outcomes. Additionally, it might be an effective prophylaxis to further progression and also the formation of a secondary full-thickness macular hole. The results of this study might contribute to a paradigm shift in macular hole surgery towards early intervention.
- 27 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (5) , 4589
Open AccessLong-Term Results of Adjunct Autologous Platelet-Rich Plasma in Lamellar Macular Hole Surgery Showing Lasting Restoration of Foveal Anatomy
The aim of this study was to evaluate the long-time results of highly concentrated autologous platelet-rich plasma (PRP) used as an adjunct in lamellar macular hole (LMH) surgery. Nineteen eyes of nineteen patients with progressive LMH were enrolled in this interventional case series, on which 23/25-gauge pars plana vitrectomy was performed and 0.1 mL of highly concentrated autologous platelet-rich plasma was applied under air tamponade. Posterior vitreous detachment was induced, and the peeling of tractive epiretinal membranes, whenever present, was performed. In cases of phakic lens status, combined surgery was carried out. Postoperatively, all patients were instructed to remain in a supine position for the first two postoperative hours. Best-corrected visual acuity (BCVA) testing, microperimetry, and spectral domain optical coherence tomography (SD-OCT) were carried out preoperatively and at minimum 6 months (in median 12 months) postoperatively. Foveal configuration was postoperatively restored in 19 of 19 patients. Two patients who had not undergone ILM peeling showed a recurring defect at 6-month follow-up. Best-corrected visual acuity improved significantly from 0.29 ± 0.08 to 0.14 ± 0.13 logMAR (p = 0.028, Wilcoxon signed-rank test). Microperimetry remained unchanged (23.38 ± 2.53 preoperatively; 23.0 ± 2.49 dB postoperatively; p = 0.67). No patients experienced vision loss after surgery, and no significant intra- or postoperative complications were observed. Using PRP as an adjunct in macular hole surgery significantly improves morphological and functional outcomes. Additionally, it might be an effective prophylaxis to further progression and also the formation of a secondary full-thickness macular hole. The results of this study might contribute to a paradigm shift in macular hole surgery towards early intervention.