Thiruvengadam Jayanthi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thiruvengadam Jayanthi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Aravindan R
2 shared publications- Priyanka Kokil
Advanced Signal and Image Processing (ASIP) Lab, Department of Electronics and Communication Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Chennai, India
2 shared publications - Subramanian Suriyan
Department of Respiratory Medicine, SRM Medical College Hospital and Research Centre, Kattankulathur, India
2 shared publications V. Devaki
2 shared publicationsB Abira Bright
Department of Biomedical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur Campus, Chennai, Tamil Nadu, India
1 shared publicationB Venkatraman
Department of Radiological Safety and Environmental Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Chennai, Tamil Nadu, India
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
A Futuristic Approach to Atrial Fibrillation Detection: Integrating Multispectral Photoplethysmography with Machine Learning Technique
Atrial Fibrillation (AF), a silent or asymptomatic arrhythmia, increases the risk of ischemic stroke if undiagnosed. Wearable Multispectral Photoplethysmography (MSPPG) enables continuous AF monitoring, reducing the discomfort associated with Holter ECG. The MSPPG signal is recorded using a developed wristband equipped with MSPPG sensors of IR (950nm), Red (660nm), and Green (526nm) wavelengths while simultaneously measuring the Electrocardiography (ECG) signal with a Holter ECG. The signal, captured at the onset of AF, underwent preprocessing to correct baselines, remove erroneous data, and filtered using a 15 Hz Butterworth low-pass filter. The denoised signal undergoes feature extraction, which encompasses essential features for AF classification in terms of the time domain, the frequency domain, and the pulse rate variability (PRV). The features selected using Analysis of Variance (ANOVA) and Recursive Feature Elimination (RFE) are employed in a Support Vector Machine (SVM) classification model for AF diagnosis with the Radial Basis Function. The performance of the model is evaluated using precision (Positive Predictive Value (PPV)), F1-Score, Negative Predictive Value (NPV), Specificity, Sensitivity (Recall), Accuracy, and AUC. The AUC, which stands at 96%, indicates that MSPPG could be a superior alternative to PPG and ECG, offering continuous monitoring with higher accuracy. A Graphical User Interface (GUI) has also been developed to diagnose probable AF based on the extracted features. The MSPPG-based AF detection technique effectively reduces false positives, improves diagnostic accuracy, and aids in the timely detection of silent AF for stroke prevention,K
- 1 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Futuristic Approach to Atrial Fibrillation Detection: Integrating Multispectral Photoplethysmography with Machine Learning Technique
Atrial Fibrillation (AF), a silent or asymptomatic arrhythmia, increases the risk of ischemic stroke if undiagnosed. Wearable Multispectral Photoplethysmography (MSPPG) enables continuous AF monitoring, reducing the discomfort associated with Holter ECG. The MSPPG signal is recorded using a developed wristband equipped with MSPPG sensors of IR (950nm), Red (660nm), and Green (526nm) wavelengths while simultaneously measuring the Electrocardiography (ECG) signal with a Holter ECG. The signal, captured at the onset of AF, underwent preprocessing to correct baselines, remove erroneous data, and filtered using a 15 Hz Butterworth low-pass filter. The denoised signal undergoes feature extraction, which encompasses essential features for AF classification in terms of the time domain, the frequency domain, and the pulse rate variability (PRV). The features selected using Analysis of Variance (ANOVA) and Recursive Feature Elimination (RFE) are employed in a Support Vector Machine (SVM) classification model for AF diagnosis with the Radial Basis Function. The performance of the model is evaluated using precision (Positive Predictive Value (PPV)), F1-Score, Negative Predictive Value (NPV), Specificity, Sensitivity (Recall), Accuracy, and AUC. The AUC, which stands at 96%, indicates that MSPPG could be a superior alternative to PPG and ECG, offering continuous monitoring with higher accuracy. A Graphical User Interface (GUI) has also been developed to diagnose probable AF based on the extracted features. The MSPPG-based AF detection technique effectively reduces false positives, improves diagnostic accuracy, and aids in the timely detection of silent AF for stroke prevention,K
- Open Access
- 29 June 2025
- Published by Atlantis Press SARL
- p. 81-92
Sleep Apnea Detection System using Internet of Things and Deep Learning Techniques
- 29 June 2025
- Published by Atlantis Press SARL
- p. 81-92
Open AccessSleep Apnea Detection System using Internet of Things and Deep Learning Techniques
- Open Access
- 23 May 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (6) , 127
Intuitive and Experiential Approaches to Enhance Conceptual Design in Architecture Using Building Information Modeling and Virtual Reality
The conceptual design phase in architecture requires both intuitive and iterative approaches, which traditional Building Information Modeling (BIM) workflows fail to support properly. BIM provides data-driven decision-making and project coordination but does not offer affective or experiential feedback capabilities. BIM and Virtual Reality (VR) integration offers a promising solution to improve user-focused spatial assessments during initial design phases. The research follows three distinct phases, including a Systematic Literature Review to identify BIM-based conceptual workflow limitations, semi-structured interviews with architects to understand practical challenges and expectations, and the development of a BIM-based framework combining immersive VR for affective and visuospatial evaluation. A testing phase of the proposed framework occurred in the pilot study. The current BIM workflows show significant deficiencies in their ability to support creative flexibility, user engagement, and experiential validation. The BIM-VR framework implemented in the pilot study showed improvements in spatial cognition, emotional engagement, and iterative design decision-making during the conceptual design phase. Early-stage architectural design evaluation becomes more effective through VR integration into BIM workflows because it provides real-time immersive user feedback. The proposed framework helps develop BIM tools that are more intuitive for humans while advancing user-informed design practices in the architecture, engineering, and construction industries.
- 23 May 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (6) , 127
Open AccessIntuitive and Experiential Approaches to Enhance Conceptual Design in Architecture Using Building Information Modeling and Virtual Reality
The conceptual design phase in architecture requires both intuitive and iterative approaches, which traditional Building Information Modeling (BIM) workflows fail to support properly. BIM provides data-driven decision-making and project coordination but does not offer affective or experiential feedback capabilities. BIM and Virtual Reality (VR) integration offers a promising solution to improve user-focused spatial assessments during initial design phases. The research follows three distinct phases, including a Systematic Literature Review to identify BIM-based conceptual workflow limitations, semi-structured interviews with architects to understand practical challenges and expectations, and the development of a BIM-based framework combining immersive VR for affective and visuospatial evaluation. A testing phase of the proposed framework occurred in the pilot study. The current BIM workflows show significant deficiencies in their ability to support creative flexibility, user engagement, and experiential validation. The BIM-VR framework implemented in the pilot study showed improvements in spatial cognition, emotional engagement, and iterative design decision-making during the conceptual design phase. Early-stage architectural design evaluation becomes more effective through VR integration into BIM workflows because it provides real-time immersive user feedback. The proposed framework helps develop BIM tools that are more intuitive for humans while advancing user-informed design practices in the architecture, engineering, and construction industries.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20584-20592
Wearable Sensor Design for Real-Time Obstructive Sleep Apnea Monitoring
Repeated breath cessation during sleep due to the closure of the airway passage is a condition known as obstructive sleep apnea (OSA). Untreated OSA elevates occupational-related fatal incidents, motor vehicle accidents, severe depression, cardiac and cerebrovascular ailments, and reduced survival expectancy. The gold standard for diagnosing OSA is polysomnography (PSG), which is an overnight sleep study. PSG is associated with higher costs and relative discomfort for the subject. In this work, a dedicated device is designed and developed to screen the individual for probable OSA. The proposed device incorporates a pressure sensor and an Arduino Nano 33 BLE Sense controller to capture the respiratory pressure signals the subject generates. An algorithm is developed to calculate essential breath metrics that include parameters such as the respiratory rate (RR), the inspiratory time (It), the expiratory time (Et) and the Apnea-Hypopnea Index (AHI). These metrics serve as indicators to grade and assess the likelihood of OSA in the subject. Additionally, the proposed system also monitors the sleeping position of the subject, temperature, and humidity as supplementary parameters to evaluate their sleep patterns comprehensively during the study. The proposed methodology offers a direct and efficient means of measuring respiratory signals for OSA assessment, thereby eliminating the need for extensive overnight sleep studies and complex multi-parameter analyses. The proposed method also allows individuals to sleep naturally without the requirement for physical restraints during monitoring, as in traditional method. This approach holds promise for more convenient and accessible OSA screening while simultaneously enabling parallel monitoring through the CPAP mask.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20584-20592
Wearable Sensor Design for Real-Time Obstructive Sleep Apnea Monitoring
Repeated breath cessation during sleep due to the closure of the airway passage is a condition known as obstructive sleep apnea (OSA). Untreated OSA elevates occupational-related fatal incidents, motor vehicle accidents, severe depression, cardiac and cerebrovascular ailments, and reduced survival expectancy. The gold standard for diagnosing OSA is polysomnography (PSG), which is an overnight sleep study. PSG is associated with higher costs and relative discomfort for the subject. In this work, a dedicated device is designed and developed to screen the individual for probable OSA. The proposed device incorporates a pressure sensor and an Arduino Nano 33 BLE Sense controller to capture the respiratory pressure signals the subject generates. An algorithm is developed to calculate essential breath metrics that include parameters such as the respiratory rate (RR), the inspiratory time (It), the expiratory time (Et) and the Apnea-Hypopnea Index (AHI). These metrics serve as indicators to grade and assess the likelihood of OSA in the subject. Additionally, the proposed system also monitors the sleeping position of the subject, temperature, and humidity as supplementary parameters to evaluate their sleep patterns comprehensively during the study. The proposed methodology offers a direct and efficient means of measuring respiratory signals for OSA assessment, thereby eliminating the need for extensive overnight sleep studies and complex multi-parameter analyses. The proposed method also allows individuals to sleep naturally without the requirement for physical restraints during monitoring, as in traditional method. This approach holds promise for more convenient and accessible OSA screening while simultaneously enabling parallel monitoring through the CPAP mask.
- Open Access
- 26 December 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 9550-9556
Green-Infrared Dominance in Atrial Fibrillation Detection
Objective: Atrial fibrillation (AF), an asymptomatic arrhythmia, poses a significant risk of stroke when not promptly detected. The primary goal is to analyze the influence of green, red, and infrared wavelengths in the detection and prediction of AF, focusing on the combinations of Green-IR (GIR) and Red-IR (RIR) wavelengths to prevent its occurrence and facilitate timely intervention.Methodology: Using the Multi-Spectral Photoplethysmography (MSPPG) signal obtained from a developed prototype incorporating Red (660 nm), Infrared (IR) (950 nm), and Green (526 nm) wavelengths, AF detection and prediction were conducted using two wavelength combinations: GIR and the commonly available RIR combination, demonstrating improved performance compared to traditional PPG methods. The signals from both combinations underwent feature extraction and classification using the Support Vector Machine with Radial Basis Function (SVM-RBF) classifier. The features extracted at the window size of onset of AF, 5mins before AF, 10mins before AF and 1 hour before the AF event are compared using the statistical analysis of Student’s t-test which demonstrates the capability of differentiating normal and abnormal conditions using both GIR and RIR combinations.Results: The results indicate that the GIR combination consistently outperforms the RIR combination across all window sizes, highlighting the superior efficacy of GIR in the detection and prediction of atrial fibrillation. Notably, the prediction using GIR yielded particularly improved results in the 5-minute window before the onset of atrial fibrillation.Conclusion: The study demonstrates the feasibility of predicting atrial fibrillation, especially within the crucial 5-minute window before onset, using the GIR combination. Early detection within this timeframe offers the potential to prevent atrial fibrillation and subsequent strokes, thereby reducing mortality rates associated with atrial fibrillation and stroke.
- 26 December 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 9550-9556
Open AccessGreen-Infrared Dominance in Atrial Fibrillation Detection
Objective: Atrial fibrillation (AF), an asymptomatic arrhythmia, poses a significant risk of stroke when not promptly detected. The primary goal is to analyze the influence of green, red, and infrared wavelengths in the detection and prediction of AF, focusing on the combinations of Green-IR (GIR) and Red-IR (RIR) wavelengths to prevent its occurrence and facilitate timely intervention.Methodology: Using the Multi-Spectral Photoplethysmography (MSPPG) signal obtained from a developed prototype incorporating Red (660 nm), Infrared (IR) (950 nm), and Green (526 nm) wavelengths, AF detection and prediction were conducted using two wavelength combinations: GIR and the commonly available RIR combination, demonstrating improved performance compared to traditional PPG methods. The signals from both combinations underwent feature extraction and classification using the Support Vector Machine with Radial Basis Function (SVM-RBF) classifier. The features extracted at the window size of onset of AF, 5mins before AF, 10mins before AF and 1 hour before the AF event are compared using the statistical analysis of Student’s t-test which demonstrates the capability of differentiating normal and abnormal conditions using both GIR and RIR combinations.Results: The results indicate that the GIR combination consistently outperforms the RIR combination across all window sizes, highlighting the superior efficacy of GIR in the detection and prediction of atrial fibrillation. Notably, the prediction using GIR yielded particularly improved results in the 5-minute window before the onset of atrial fibrillation.Conclusion: The study demonstrates the feasibility of predicting atrial fibrillation, especially within the crucial 5-minute window before onset, using the GIR combination. Early detection within this timeframe offers the potential to prevent atrial fibrillation and subsequent strokes, thereby reducing mortality rates associated with atrial fibrillation and stroke.
- 1 November 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (12) , 920-927
Design of eye phantom for optical coherence tomography angiography study
Tissue phantoms play an important role in validating biomedical imaging techniques. For optical imaging systems such as optical coherence tomography, creating layers of phantoms with different refractive indices is important. This paper explored various phantom materials to create eye-mimicking phantoms. The phantom also included microfluidic channels to mimic vasculature. To verify the optical properties of the created phantom, the transmission and reflection spectroscopy was performed using a photoluminescent spectrometer studying the complete visible and near infrared spectrum. We created a 3D model to house multiple layers that mimicked the retina at one end and the contact lens at the other, representing the anterior segment of the eye. A realistic retinal layer-mimicking, which, among other things, may pave the way for new combined imaging modalities
- 1 November 2024
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 47 (12) , 920-927
Design of eye phantom for optical coherence tomography angiography study
Tissue phantoms play an important role in validating biomedical imaging techniques. For optical imaging systems such as optical coherence tomography, creating layers of phantoms with different refractive indices is important. This paper explored various phantom materials to create eye-mimicking phantoms. The phantom also included microfluidic channels to mimic vasculature. To verify the optical properties of the created phantom, the transmission and reflection spectroscopy was performed using a photoluminescent spectrometer studying the complete visible and near infrared spectrum. We created a 3D model to house multiple layers that mimicked the retina at one end and the contact lens at the other, representing the anterior segment of the eye. A realistic retinal layer-mimicking, which, among other things, may pave the way for new combined imaging modalities
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Physical Sensor Driven Approach for Optimizing Positive Airway Pressure Therapy
Obstructive sleep apnea (OSA) is a sleep disorder for which continuous positive airway pressure (CPAP) therapy is an effective treatment. In this study, a novel method to control the pressure in the positive airway pressure (PAP) device is proposed, this, in return, reduces the need to keep the subject at high pressure throughout extended period of their sleep without hindering the efficacy of the therapy. A standard CPAP/Bi-PAP (Bi-level Positive Airway Pressure) titration study is compared and verified with the predicted pressure values. Also the relationship and correlation between weight, age, SpO 2 , oxygen desaturation index (ODI), and the maximum pressure required for PAP therapy are also analyzed. Thus it is affirmed that, the PAP therapy compliance can be improved by sustaining the essential pressure and avoiding extended high-pressure intervals during therapy, unless they are absolutely required.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Physical Sensor Driven Approach for Optimizing Positive Airway Pressure Therapy
Obstructive sleep apnea (OSA) is a sleep disorder for which continuous positive airway pressure (CPAP) therapy is an effective treatment. In this study, a novel method to control the pressure in the positive airway pressure (PAP) device is proposed, this, in return, reduces the need to keep the subject at high pressure throughout extended period of their sleep without hindering the efficacy of the therapy. A standard CPAP/Bi-PAP (Bi-level Positive Airway Pressure) titration study is compared and verified with the predicted pressure values. Also the relationship and correlation between weight, age, SpO 2 , oxygen desaturation index (ODI), and the maximum pressure required for PAP therapy are also analyzed. Thus it is affirmed that, the PAP therapy compliance can be improved by sustaining the essential pressure and avoiding extended high-pressure intervals during therapy, unless they are absolutely required.
- Open Access
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 8501-8507
Non-Invasive Cloud Based Serverless Application for Acute Respiratory Distress Syndrome
Acute Respiratory Distress Syndrome (ARDS) is a fatal lung disease that allows fluid buildup in the lungs restricting the amount of oxygen that reaches the organs through the bloodstream. The application focuses on detecting ARDS in patients using their oxygen saturation value; by doing so, the detection of ARDS becomes more accessible and convenient to people. The conventional method of detecting ARDS is to compare the Horowitz index, it is obtained as the ratio of the partial pressure of oxygen (PaO2) measured in mmHg to the fraction of inspired oxygen (FiO2) represented in fraction, instead of the conventional method we have utilized the ratio between oxygen saturation value (SpO2) to the fraction of inspired oxygen (FiO2) as it is non-invasive, accessible and less time and money consuming. Using Amazon Web Services (AWS), a serverless web application has been developed and converted to an Android mobile application as AWS provides cloud storage services. AWS S3 bucket service stores and manages web application index and error pages. DynamoDB is a cloud storage service offered by AWS. In this work, it is used to store the subject’s information. In Lambda, a function is created by considering the relation between SpO2/FiO2 ratio and ARDS. API gateway acts as an interface between the front end and back end of an application. Rest API is used to create the serverless application.
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 8501-8507
Open AccessNon-Invasive Cloud Based Serverless Application for Acute Respiratory Distress Syndrome
Acute Respiratory Distress Syndrome (ARDS) is a fatal lung disease that allows fluid buildup in the lungs restricting the amount of oxygen that reaches the organs through the bloodstream. The application focuses on detecting ARDS in patients using their oxygen saturation value; by doing so, the detection of ARDS becomes more accessible and convenient to people. The conventional method of detecting ARDS is to compare the Horowitz index, it is obtained as the ratio of the partial pressure of oxygen (PaO2) measured in mmHg to the fraction of inspired oxygen (FiO2) represented in fraction, instead of the conventional method we have utilized the ratio between oxygen saturation value (SpO2) to the fraction of inspired oxygen (FiO2) as it is non-invasive, accessible and less time and money consuming. Using Amazon Web Services (AWS), a serverless web application has been developed and converted to an Android mobile application as AWS provides cloud storage services. AWS S3 bucket service stores and manages web application index and error pages. DynamoDB is a cloud storage service offered by AWS. In this work, it is used to store the subject’s information. In Lambda, a function is created by considering the relation between SpO2/FiO2 ratio and ARDS. API gateway acts as an interface between the front end and back end of an application. Rest API is used to create the serverless application.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2603 (1)
A glance into effective electrocardiographic signal processing for automated arrhythmia detection and cardioversion
The human heart beats rhythmically, maintaining a steady beat to pump blood across the body. This constant beating is also required to maintain the vessel blood pressure, preventing circulatory collapse and subsequently ischemia or infarction. Arrhythmia or irregular rhythm, due to a pre-existing condition or damage to the heart’s neuromuscular structure, can lead to a change in the heart rate and the flow pressure in the blood vessels. In resolvable or temporary arrhythmia, the therapeutic procedure of choice remains synchronized cardioversion. Cardioversion, a procedure akin to defibrillation, essentially involves reconfiguring the heart’s electrical system by delivering a calculated charge of electric current at the appropriate junction in the cardiac rhythm. However, if performed unnecessarily or incorrectly, cardioversion can result in arrhythmia or cardiac arrest. Thus in cases requiring the utilization of this protocol, it is of vital importance to monitor the patient’s cardiac rhythm and deliver the cardioversive shock only at the appropriate juncture. This paper reviews the various techniques utilized to track and deliver cardioversion.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2603 (1)
Open AccessA glance into effective electrocardiographic signal processing for automated arrhythmia detection and cardioversion
The human heart beats rhythmically, maintaining a steady beat to pump blood across the body. This constant beating is also required to maintain the vessel blood pressure, preventing circulatory collapse and subsequently ischemia or infarction. Arrhythmia or irregular rhythm, due to a pre-existing condition or damage to the heart’s neuromuscular structure, can lead to a change in the heart rate and the flow pressure in the blood vessels. In resolvable or temporary arrhythmia, the therapeutic procedure of choice remains synchronized cardioversion. Cardioversion, a procedure akin to defibrillation, essentially involves reconfiguring the heart’s electrical system by delivering a calculated charge of electric current at the appropriate junction in the cardiac rhythm. However, if performed unnecessarily or incorrectly, cardioversion can result in arrhythmia or cardiac arrest. Thus in cases requiring the utilization of this protocol, it is of vital importance to monitor the patient’s cardiac rhythm and deliver the cardioversive shock only at the appropriate juncture. This paper reviews the various techniques utilized to track and deliver cardioversion.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2603 (1)
Assessment of hypertensive retinopathy based on cotton wool spots
Uncontrolled hypertension is accompanied by targeted organ damage. A secondary condition related to hypertension is hypertensive retinopathy (HRP). It is the condition where the retinal vasculature gets damaged due to pressure variations in the blood vessels. Since poorly controlled systemic hypertension can harm the microcirculation of the retina, identification of HRP is paramount in cardiovascular risk stratification for hypertensive patients. Cotton wool spots (CWS) are fluffy white-yellow conspicuous lesions present within the innermost retina. Grading them based on the area of CWS can be an important marker for HRP. The identification of CWS necessitates the segmentation of blood vessels in the retinal images. This automatic blood vessel segmentation would serve as a diagnostic tool for several retinal diseases and assist in efficient clinical diagnosis. The proposed system comprises an instinctual blood vessel segmentation method for retinal images and identification of CWS. The morphological operations use the vessel enhanced intensity and green channel intensity features to make up a multidimensional feature vector. Initially, in the preprocessing steps, the inconsistent illumination of retinal images is eliminated, and vessel contrast is enhanced. After that, Convolutional Neural Network (CNN) was used to extract several graded features that are uniform to image translation, scaling, skewing, and other distortions. Ensemble Random Forest classifier was used for vessel classification. The entire channel of the proposed method is automatic and trainable. The area of the CWS is calculated as a scalar quantity estimating the number of pixels in the segmented area of CWS.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2603 (1)
Open AccessAssessment of hypertensive retinopathy based on cotton wool spots
Uncontrolled hypertension is accompanied by targeted organ damage. A secondary condition related to hypertension is hypertensive retinopathy (HRP). It is the condition where the retinal vasculature gets damaged due to pressure variations in the blood vessels. Since poorly controlled systemic hypertension can harm the microcirculation of the retina, identification of HRP is paramount in cardiovascular risk stratification for hypertensive patients. Cotton wool spots (CWS) are fluffy white-yellow conspicuous lesions present within the innermost retina. Grading them based on the area of CWS can be an important marker for HRP. The identification of CWS necessitates the segmentation of blood vessels in the retinal images. This automatic blood vessel segmentation would serve as a diagnostic tool for several retinal diseases and assist in efficient clinical diagnosis. The proposed system comprises an instinctual blood vessel segmentation method for retinal images and identification of CWS. The morphological operations use the vessel enhanced intensity and green channel intensity features to make up a multidimensional feature vector. Initially, in the preprocessing steps, the inconsistent illumination of retinal images is eliminated, and vessel contrast is enhanced. After that, Convolutional Neural Network (CNN) was used to extract several graded features that are uniform to image translation, scaling, skewing, and other distortions. Ensemble Random Forest classifier was used for vessel classification. The entire channel of the proposed method is automatic and trainable. The area of the CWS is calculated as a scalar quantity estimating the number of pixels in the segmented area of CWS.