JSJoachim Starup-Hansen

Joachim Starup-Hansen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joachim Starup-Hansen has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Hani J. Marcus

    Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Victor Horsley, UCL Queen Square Institute of Neurology, University College London, London, UK

    5 shared publications
  • Danyal Z. Khan

    Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK

    4 shared publications
  • Hani J. Marcus

    Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK

    3 shared publications
  • Jigishaa Moudgil-Joshi

    Department of Neurosurgery, University College London Hospitals NHS Foundation Trust, London, UK; Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK; The Francis Crick Institute, London, UK

    3 shared publications
  • Simon C. Williams

    Department of Neurosurgery, University College London Hospitals NHS Foundation Trust, London, UK; Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK

    3 shared publications
  • Alexandra Valetopoulou

    Victor Horsley Department of Neurosurgery, The National Hospital for Neurology and Neurosurgery, University College London NHS Trust, London, United Kingdom

    2 shared publications

Latest Publications

  • Open Access

    Action classification for endoscopic pituitary adenoma resection: a consensus-based study

    by Joachim Starup-Hansen, Danyal Z. Khan, Adrito Das, Joao Paulo Almeida, Sophia Bano, Anouk Borg, Kevin Cleary, Neil Dorward, Juan C. Fernandez-Miranda, Eduardo Torres-Rodríguez, et al.

    Purpose: Pituitary adenoma resection via the endoscopic transsphenoidal approach is technically demanding, with outcomes influenced by surgical skill. However, the association between technique and outcomes remains poorly defined. Existing workflow analyses focus on broad procedural steps and phases, but a more detailed, action-level approach is needed to capture skill-related variation. While AI shows promise in automating workflow analysis, its use at the action level is limited. This study develops and validates a reproducible action-level classification ontology for endoscopic pituitary adenoma resection, establishing the structured annotation foundation required for future AI-based workflow and skill analysis. Methods: Endoscopic videos of primary pituitary adenoma resections were collected from two high-volume international pituitary centres. A multi-disciplinary panel of neurosurgeons and data scientists iteratively reviewed and annotated surgical actions to establish a standardized classification system. Actions were categorized into triplets (instrument, target, verb), with additional temporal annotations. To evaluate framework reliability, an independent annotator followed a structured annotation guide, and inter-annotator agreement was measured using Cohen’s Kappa. Results: A consensus-based classification ontology was developed, comprising 9 verbs, 12 instruments, and 7 targets from the review of 18 endoscopic pituitary adenoma resections (9 microadenomas, 9 macroadenomas). Action distribution differed between micro- and macroadenomas, with grasping being the predominant action in microadenomas (72% of right-hand frames) and blunt dissection and traction dominating macroadenomas. The left hand primarily performed non-meaningful movements (88% of macroadenoma frames, 55% of microadenoma frames), while the right hand was responsible for more deliberate tool–tissue interactions. Inter-rater reliability analysis demonstrated substantial to near-perfect agreement ( κ = 0.69–0.95), confirming the reproducibility of the annotation system. Conclusion: While acknowledging that conclusions remain limited by dataset size and validation stability, this study establishes a robust and interpretable action classification ontology for pituitary adenoma resection. The ontology enables high-quality, standardized labelling for future computer-vision AI works, and lays the groundwork for evaluating whether action-level annotation improves surgical outcome prediction and automated skill assessment.

  • Open Access

    A Scoping Review of the Ergonomics of Handheld Surgical Robots

    by Joseph Shehata, Tjasa Zaletel, Shuja Yaqub, Joachim Starup-Hansen, Emmanouil Dimitrakakis, John G Hanrahan, Danail Stoyanov, Hani J Marcus

    Handheld surgical robots aim to improve dexterity with lower cost and footprint than console systems, but their ergonomic impact is unclear. We performed a scoping review (inception − 27 July 2025) of English-language primary studies of handheld robotic instruments across six databases and targeted grey literature. Dual-reviewer screening and charting were used, with narrative synthesis. From 2,675 records, 79 studies met inclusion: 21 evaluated ergonomics. Most relied on subjective questionnaires; validated workload tools (NASA-TLX/SURG-TLX) and objective measures (RULA, wearables) were uncommon. Twelve commercial systems were identified; only three had peer-reviewed ergonomic data. Reported ergonomic aims included reducing weight, maintaining neutral wrist posture and intuitive control mapping; sex-disaggregated outcomes were rare. Evidence remains heterogeneous and insufficiently standardised; we recommend hybrid, validated protocols and inclusive design to ensure safe, equitable adoption.

  • Open Access

    Applicability of a Dexterity-Enhancing Handheld Robot for 360° Endoscopic Skull Base Approaches: An Exploratory Cadaver Study

    by Joachim Starup-Hansen, Dan Zimelewicz Oberman, John G. Hanrahan, Emmanouil Dimitrakakis, Hani J. Marcus, Joao Paulo Almeida

    BACKGROUND AND OBJECTIVES: Endoscopic skull base surgery aims to reduce surgical morbidity by minimizing tissue manipulation and exposure. However, the anatomic constraints posed by the narrow surgical corridors and constrained operative workspace present technical challenges due to reduced dexterity. This study evaluates the applicability of a novel dexterity-enhancing handheld robot for endoscopic skull base approaches. METHODS: The robotic system is comprised of interchangeable articulated end-effectors coupled to a handheld controller. Two attending skull base neurosurgeons and 2 neurosurgery residents performed 8 skull base approaches on cadaveric specimens, spanning anterior, anterolateral, lateral, posterolateral, and posterior approaches. Conventional instruments were used to expose anatomic landmarks, followed by intraoperative tasks using the handheld robot. Participants were interviewed during the procedures to assess the robot's feasibility (ability to safely reach and perform its objective of manipulating tissue at the operative site) and usefulness (ability to perform desired objectives well). RESULTS: The handheld robotic system was tested across 8 endoscopic skull base approaches, achieving feasibility in all cases. Superior workspace reach compared with standard instruments was demonstrated in 6 of 8 approaches. Tissue manipulation was satisfactory in all approaches. All surgeons reported that the current or a future device prototype could be useful across all 8 approaches. The most frequently cited advantage was the expanded dextrous workspace reach provided by the articulated end-effectors, particularly in approaches with long working channels, such as the endonasal approach. However, the robot encountered difficulties in transcranial approaches (trans-sylvian and subtemporal) due to the lack of shorter, curved shafts, which impaired visualization. CONCLUSION: The handheld robotic system demonstrated applicability across various endoscopic skull base approaches, offering increased dextrous workspace and effective tissue manipulation capabilities. Overall, this study supports the potential of handheld robots in endoscopic skull base surgery while highlighting the need for iterative development to optimize instrument design and functionality.


  • Open Access

    3D reconstruction in endonasal pituitary surgery

    by Dannielle Lee, Laurent Mennillo, Emalee Burrows, Jia-En Chen, Danyal Z. Khan, Joachim Starup-Hansen, Danail Stoyanov, Matthew J. Clarkson, Hani J. Marcus, Sophia Bano

    Purpose: Endoscopic transsphenoidal surgery for pituitary tumors is hindered by limited visibility and maneuverability due to the narrow nasal corridor, increasing the risk of complications. To address these challenges, we present a pipeline for 3D reconstruction of the sellar anatomy from monocular endoscopic videos to enhance intraoperative visualization and navigation. Methods: Data were collected through a user study with trainee surgeons, and the procedure was conducted on 3D printed, anatomically correct phantom devices. To overcome limitations posed by the uniform, textureless surfaces of these devices, learned feature detectors and matchers were leveraged to extract meaningful information from the images. The matched features were reconstructed using COLMAP, and the resulting surfaces were evaluated using the iterative closest point algorithm against the CAD ground-truth surface of the printed phantoms. Results: Most methods resulted in accurate reconstructions with moderate variability in cases with high blur or occlusions. Average RMSE values of 0.33 mm and 0.41 mm, for the two best methods, Dense Kernelized Feature Matching and SuperPoint with LightGlue, respectively, were obtained in the surface registrations across all test sequences, with a significantly higher computation time for Dense Kernelized Feature Matching. Conclusion: The proposed pipeline was able to accurately reconstruct anatomically correct 3D models of the phantom devices, showing potential for the use of learned feature detectors and matchers in real time for AR-guided navigation in pituitary surgery.


  • Open Access

    Patient and Public Perceptions of Simulation Training in Neurosurgery: A Two-Stage Cross-Sectional Survey

    by Oliver E. Burton, Joachim Starup-Hansen, Jigishaa Moudgil-Joshi, Simon C. Williams, Chan Hee Koh, Hani J. Marcus


  • Open Access

    A Handheld Robot for Endoscopic Endonasal Skull Base Surgery: Updated Preclinical Validation Study (IDEAL Stage 0)

    by Joachim Starup-Hansen, Nicola Newall, Emmanouil Dimitrakakis, Danyal Z. Khan, George Dwyer, Keshav Iyengar, Dimitrios Psychogyios, John G. Hanrahan, Siddharth Sinha, James Booker, et al.

    Background and Objectives Endoscopic endonasal surgery (EES) has become increasingly popular, yet anatomical constraints posed by the nose and limitations of nonarticulated instruments render EES technically challenging, with a steep associated learning curve. Therefore, we developed a handheld robot to enhance dexterity in endoscopic neurosurgical procedures. A previous trial of the robot demonstrated its potential advantages in endoscopic neurosurgery but also the need for improvements. In this study, we assess the feasibility, acceptability, and comparative performance of the updated robotic prototype (version 0.2) against standard instruments in a preclinical phantom and cadaveric trial. Methods Ethical approval was received. Participants were stratified according to their neurosurgical experience. In the phantom study, a randomized crossover design compared the robot against standard instruments at a phantom tumor resection task. Statistical analysis was performed using Mann–Whitney U tests and paired t-tests. In the cadaver-based user study, participants evaluated the device's functional domains through a qualitative interview design. Results In the phantom study, the device demonstrated a learning curve: initial resection attempts favored the traditional instrument (84% vs. 59%, p = 0.055), but parity was achieved by the fifth attempt (80% vs. 83%, p = 0.76). Acceptability was evident, as most clinicians (7/8) preferred the robot for its superior range, ergonomics, and precision. Also, the robot exhibited a diminished cognitive workload. The cadaveric study underscored the robot's clinical feasibility, through sufficient workspace reach and force delivery. Conclusion: Overall, our robot demonstrates promising acceptability and feasibility for endoscopic neurosurgery, yet further iterative developments are required before proceeding to in-human clinical trials. * First author equal contribution. # Senior author equal contribution. Received: 19 October 2023 Accepted: 09 March 2024 Accepted Manuscript online: 01 April 2024 Article published online: 15 April 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Skull Base Repair following Resection of Vestibular Schwannoma: A Systematic Review (Part 1: The Retrosigmoid Approach)

    by Joachim Starup-Hansen, Simon C. Williams, Alexandra Valetopoulou, Danyal Z. Khan, Hugo Layard Horsfall, Jigishaa Moudgil-Joshi, Oliver Burton, Hala Kanona, Shakeel R. Saeed, William Muirhead, et al.

    Objective Despite advances in skull-base reconstruction techniques, cerebrospinal fluid (CSF) leaks remain a common complication following retrosigmoid (RS) vestibular schwannoma (VS) surgery. We aimed to review and classify the available strategies used to prevent CSF leaks following RS VS surgery. Methods A systematic review, including studies of adults undergoing RS VS surgery since 2000, was conducted. Repair protocols were synthesized into a narrative summary, and a taxonomic classification of techniques and materials was produced. Additionally, the advantages, disadvantages, and associated CSF leak rates of different repair protocols were described. Results All 42 studies were case series, of which 34 were retrospective, and eight were prospective. Repair strategies included heterogeneous combinations of autografts, xenografts, and synthetic materials. A repair taxonomy was produced considering seven distinct stages to CSF leak prevention, including intraoperative approaches to the dura, internal auditory canal (IAC), air cells, RS bony defect, extracranial soft tissue, postoperative dressings, and CSF diversion. Notably, there was significant heterogeneity among institutions, particularly in the dural and IAC stages. The median postoperative incidence of CSF leaks was 6.3% (IQR: 1.3–8.44%). Conclusions The intraoperative strategies used to prevent CSF leaks during RS VS surgery vary between and within institutions. As a result of this heterogeneity and inconsistent reporting of CSF leak predictive factors, a meaningful comparative analysis of repair protocols was not feasible. Instead, we propose the development of a prospective multicenter observational evaluation designed to accurately capture a comprehensive dataset of potential CSF risk factors, including all stages of the operative repair protocol. * Equal senior authorship. Received: 05 September 2023 Accepted: 25 November 2023 Accepted Manuscript online: 04 December 2023 Article published online: 22 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Skull Base Repair following Resection of Vestibular Schwannoma: A Systematic Review (Part 2: The Translabyrinthine Approach)

    by Joachim Starup-Hansen, Simon C. Williams, Alexandra Valetopoulou, Danyal Z. Khan, Hugo Layard Horsfall, Jigishaa Moudgil-Joshi, Oliver Burton, Hala Kanona, Shakeel R. Saeed, William Muirhead, et al.

    Objectives Despite advances in skull base reconstruction techniques, cerebrospinal fluid (CSF) leaks remain a relatively common complication after translabyrinthine (TL) vestibular schwannoma (VS) surgery. We conducted a systematic review to synthesize the repair techniques and materials used in TL VS surgery to prevent CSF leaks. Design A systematic review of studies published since 2000 reporting techniques to prevent CSF leaks during adult TL VS surgery was conducted. A narrative synthesis of primary repair protocols was produced, and a taxonomy was established. Additionally, the advantages, disadvantages, and associated CSF leak rates of different repair protocols were extracted. Results All 43 studies were case series, and 39 were retrospective. Repair strategies included heterogeneous combinations of autografts, xenografts, and synthetic materials. A taxonomy was produced, classifying repairs into seven distinct stages, including approaches to the dura, middle ear cleft, air cells, TL bony defect, extra-cranial soft tissue, postoperative dressings, and CSF diversion. The median postoperative incidence of CSF leaks was 6% (interquartile range: 0–10%). Conclusions This systematic review reveals substantial inter-institutional heterogeneity in intraoperative strategies to prevent CSF leaks following TL VS surgery. However, comparing these techniques is challenging due to the multiple predictive factors for CSF leaks and their inconsistent reporting. We propose a taxonomy of seven stages to classify operative techniques and materials aimed at preventing CSF leaks. We recommend that future evaluations should adopt a prospective approach encompassing data collection strategies that considers all operative stages described by our taxonomy. * Equal senior authorship. Received: 05 September 2023 Accepted: 25 November 2023 Accepted Manuscript online: 04 December 2023 Article published online: 22 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany