José Raimundo de Oliveira Júnior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
José Raimundo de Oliveira Júnior has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alanio Ferreira de Lima
Federal University of Ceará
1 shared publication - Antonio Barbosa de Souza Júnior
Electrical Engineering Department, GPAR - Research Group on Automation, Control and Robotics, Federal University of Ceara, Fortaleza, Brazil
1 shared publication - Clauson Sales Do Nascimento Rios
Department of Electrical Engineering, Federal University of Ceará, Fortaleza 60455-760, CE, Brazil
1 shared publication - Darielson A. Souza
Electrical Engineering Department, GPAR - Research Group on Automation, Control and Robotics, Federal University of Ceara, Fortaleza, Brazil
1 shared publication - Felipe José de Sousa Vasconcelos
Department of Electrical Engineering, Federal University of Ceará, Fortaleza 60455-760, CE, Brazil
1 shared publication - Giovanni Cordeiro Barroso
Universidade Federal do Ceará
1 shared publication
Latest Publications
- Open Access
An Improved Optimization Function to Integrate the User’s Comfort Perception into a Smart Home Controller Based on Particle Swarm Optimization and Fuzzy Logic
Scheduling residential loads for financial savings and user comfort may be performed by smart home controllers (SHCs). For this purpose, the electricity utility’s tariff variation costs, the lowest tariff cost schedules, the user’s preferences, and the level of comfort that each load may add to the household user are examined. However, the user’s comfort modeling, found in the literature, does not take into account the user’s comfort perceptions, and only uses the user-defined preferences for load on-time when it is registered in the SHC. The user’s comfort perceptions are dynamic and fluctuating, while the comfort preferences are fixed. Therefore, this paper proposes the modeling of a comfort function that takes into account the user’s perceptions using fuzzy logic. The proposed function is integrated into an SHC that uses PSO for scheduling residential loads, and aims at economy and user comfort as multiple objectives. The analysis and validation of the proposed function includes different scenarios related to economy–comfort, load shifting, consideration of energy tariffs, user preferences, and user perceptions. The results show that it is more beneficial to use the proposed comfort function method only when the user requires SHC to prioritize comfort at the expense of financial savings. Otherwise, it is more beneficial to use a comfort function that only considers the user’s comfort preferences and not their perceptions.
Open AccessAn Improved Optimization Function to Integrate the User’s Comfort Perception into a Smart Home Controller Based on Particle Swarm Optimization and Fuzzy Logic
Scheduling residential loads for financial savings and user comfort may be performed by smart home controllers (SHCs). For this purpose, the electricity utility’s tariff variation costs, the lowest tariff cost schedules, the user’s preferences, and the level of comfort that each load may add to the household user are examined. However, the user’s comfort modeling, found in the literature, does not take into account the user’s comfort perceptions, and only uses the user-defined preferences for load on-time when it is registered in the SHC. The user’s comfort perceptions are dynamic and fluctuating, while the comfort preferences are fixed. Therefore, this paper proposes the modeling of a comfort function that takes into account the user’s perceptions using fuzzy logic. The proposed function is integrated into an SHC that uses PSO for scheduling residential loads, and aims at economy and user comfort as multiple objectives. The analysis and validation of the proposed function includes different scenarios related to economy–comfort, load shifting, consideration of energy tariffs, user preferences, and user perceptions. The results show that it is more beneficial to use the proposed comfort function method only when the user requires SHC to prioritize comfort at the expense of financial savings. Otherwise, it is more beneficial to use a comfort function that only considers the user’s comfort preferences and not their perceptions.