Yirged Antehun Mengstie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yirged Antehun Mengstie has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Esayas Alemayehu
Faculty of Civil and Environmental Engineering, Jimma University, Jimma, Ethiopia
1 shared publication - Wendesen Mekonin Desta
Department of Water Supply and Environmental Engineering, Faculty of Civil and Environmental Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia
1 shared publication
Latest Publications
- Open Access
- 14 August 2023
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2023, 1-15
Assessment of Drinking Water Quality in Urban Water Supply Systems: The Case of Hawassa City, Ethiopia
In many developing countries, such as Ethiopia, water quality and the risk of water-related diseases are serious public health issues. The present study goal was to assess the drinking water quality from source to household tap water. To characterize and analyze drinking water quality parameters, 21 water samples were collected, of which 11 water samples were collected from sources (spring, borehole, and river), 4 from service reservoirs, and 6 from tap water. The mean values of the parameters were as follows: total dissolved solids (TDS) (142.79mg/L), temperature (22.08C), turbidity (9.49NTU), electrical conductivity (EC) (250.14μS/cm), pH (7.45mg/L), fluoride (1.15mg/L), nitrate (NO3−) (2.91mg/L), total hardness (TH) (57.45mg/L), calcium (41.7 6mg/l), magnesium (10.74mg/L), phosphate (0.44mg/L), sulfate (3.99mg/L), residual chlorine (1.53mg/L), alkalinity (196.39mg/L), and microbiological (total coliform and coliform/CFU) which were the main physiochemical parameters analyzed for the study. The findings revealed that the majority of the water quality parameters tested were within the WHO and National Drinking Water Quality Standards (NDWQS). However, some of the parameters such as temperature, turbidity, fluoride, and residual chlorine did not meet the standards. The mean temperatures at the source, reservoir, and tap water were 22.01C 22.5C,and 21.83C, respectively. Turbidity levels in source samples ranged from 10 to 45NTU, with a mean of 24.5NTU, exceeding the WHOs recommendation of less than 5NTU. The Boko Alamura well had a high fluoride content (3.9mg/l), which was above the WHO and NDWQS permissible limits. There was no free residual chlorine in the tap water sample. The results show that the Hawassa drinking water supply did not contain total or fecal coliform in any of the samples tested. The overall WQI for the water source, reservoir, and tap water was also determined to be 89, 71, and 69.7 points, respectively. Therefore, based on the WQI result, Hawassa drinking water quality is good for the source, reservoir, and tap water.
- 14 August 2023
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2023, 1-15
Open AccessAssessment of Drinking Water Quality in Urban Water Supply Systems: The Case of Hawassa City, Ethiopia
In many developing countries, such as Ethiopia, water quality and the risk of water-related diseases are serious public health issues. The present study goal was to assess the drinking water quality from source to household tap water. To characterize and analyze drinking water quality parameters, 21 water samples were collected, of which 11 water samples were collected from sources (spring, borehole, and river), 4 from service reservoirs, and 6 from tap water. The mean values of the parameters were as follows: total dissolved solids (TDS) (142.79mg/L), temperature (22.08C), turbidity (9.49NTU), electrical conductivity (EC) (250.14μS/cm), pH (7.45mg/L), fluoride (1.15mg/L), nitrate (NO3−) (2.91mg/L), total hardness (TH) (57.45mg/L), calcium (41.7 6mg/l), magnesium (10.74mg/L), phosphate (0.44mg/L), sulfate (3.99mg/L), residual chlorine (1.53mg/L), alkalinity (196.39mg/L), and microbiological (total coliform and coliform/CFU) which were the main physiochemical parameters analyzed for the study. The findings revealed that the majority of the water quality parameters tested were within the WHO and National Drinking Water Quality Standards (NDWQS). However, some of the parameters such as temperature, turbidity, fluoride, and residual chlorine did not meet the standards. The mean temperatures at the source, reservoir, and tap water were 22.01C 22.5C,and 21.83C, respectively. Turbidity levels in source samples ranged from 10 to 45NTU, with a mean of 24.5NTU, exceeding the WHOs recommendation of less than 5NTU. The Boko Alamura well had a high fluoride content (3.9mg/l), which was above the WHO and NDWQS permissible limits. There was no free residual chlorine in the tap water sample. The results show that the Hawassa drinking water supply did not contain total or fecal coliform in any of the samples tested. The overall WQI for the water source, reservoir, and tap water was also determined to be 89, 71, and 69.7 points, respectively. Therefore, based on the WQI result, Hawassa drinking water quality is good for the source, reservoir, and tap water.