Kai-Shing Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kai-Shing Yang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Chi-Chuan Wang
Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan
9 shared publications - Jia-Wei Zheng
Graduate Institute of Precision Manufacturing, National Chin-Yi University of Technology , No. 57, Sec. 2, Zhongshan Rd., Taiping District, Taichung 411
4 shared publications - Jin-Cherng Shyu
National Kaohsiung University of Science and Technology, Taiwan
4 shared publications - Chih-Yung Tseng
Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4, Chung Hsing Rd., Hsinchu 310, Taiwan
3 shared publications Yu-Lieh Wu
3 shared publications- Yu-Lieh Wu
National Chin-Yi University of Technology Department of Refrigeration, Air Conditioning, and Energy Engineering No.57, Sec. 2, Zhongshan Rd., Taiping Dist.,Taichung 411, Taiwan
3 shared publications
Latest Publications
- 30 March 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 245
Falling film thickness distribution around a horizontal tube under countercurrent air flow
- 30 March 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 245
Falling film thickness distribution around a horizontal tube under countercurrent air flow
- Open Access
- 18 January 2024
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 19, 885-891
Wrap-around loop pulsating heat-pipe heat exchanger for enhancing the energy efficiency of high-tech cleanroom HVAC systems
To maintain strict temperature, humidity, and cleanliness requirements, the cleanrooms of high-tech semiconductor fabrication plants have heating, ventilation, and air conditioning (HVAC) systems, which require substantial amounts of energy. To reduce energy consumption, this study proposes using a wrap-around loop pulsating heat pipe (WLPHP) heat exchanger comprising a pulsating heat pipe for precooling high-temperature outdoor air to reduce relative humidity. The heat absorbed by the heat-pipe evaporator is then transferred to the condenser and released, reducing the energy required to subsequently reheat the air with an HVAC system. The experimental results reveal that the system reduces the required reheating energy and increased the moisture removal rate per unit energy consumption by an average of 24.8% and 33% compared with a typical heat exchanger. Hence, using the WLPHP heat exchanger in HVAC systems could provide large energy savings.
- 18 January 2024
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 19, 885-891
Open AccessWrap-around loop pulsating heat-pipe heat exchanger for enhancing the energy efficiency of high-tech cleanroom HVAC systems
To maintain strict temperature, humidity, and cleanliness requirements, the cleanrooms of high-tech semiconductor fabrication plants have heating, ventilation, and air conditioning (HVAC) systems, which require substantial amounts of energy. To reduce energy consumption, this study proposes using a wrap-around loop pulsating heat pipe (WLPHP) heat exchanger comprising a pulsating heat pipe for precooling high-temperature outdoor air to reduce relative humidity. The heat absorbed by the heat-pipe evaporator is then transferred to the condenser and released, reducing the energy required to subsequently reheat the air with an HVAC system. The experimental results reveal that the system reduces the required reheating energy and increased the moisture removal rate per unit energy consumption by an average of 24.8% and 33% compared with a typical heat exchanger. Hence, using the WLPHP heat exchanger in HVAC systems could provide large energy savings.
- 14 August 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 235
Performance of the frosting characteristics of fin-and-tube heat exchanger subject to superhydrophobic coating
- 14 August 2023
- Published by Elsevier in Applied Thermal Engineering
- Vol. 235
Performance of the frosting characteristics of fin-and-tube heat exchanger subject to superhydrophobic coating
- Open Access
Special Issue: “Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems”
Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems provide physical environment comfort for the occupants at a possible expense of large amount of energy consumption
Open AccessSpecial Issue: “Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems”
Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems provide physical environment comfort for the occupants at a possible expense of large amount of energy consumption
- Open Access
Experimental Analysis of a Heat Pump Dryer with an External Desiccant Wheel Dryer
This study examines the performance of three heat pump dryers: the original reference design, a modified drying chamber, and an external desiccant wheel design. Unlike most existing studies that normally adopt organic products as the drying materials, in this study we used moist sodium polyacrylate (Orbeez) as the drying material for consistent characterization of the heat pump performance. R-134a was adopted as the refrigerant for the heat pump system. The experiments were performed subject to different weights of Orbeez (drying material) at a constant volumetric flow rate of 100 m3/h. During experimentation, different parameters like the coefficient of performance (COPHP), drying rate, heat transfer rate by the condenser, moisture extraction rate, and specific moisture extraction rate were calculated. The average COPHP, mass transfer rate, heat transfer rate, MER, and SMER of the system were calculated as 3.9, 0.30 kg/s, 0.56 kW, 0.495 kg/h, and 1.614 kg/kWh, respectively. The maximum COP for the refrigeration system was achieved at lower test loads with the desiccant wheel. The moisture extraction rate for a lower test loading was higher than that for a higher test load due to the higher penetration of drying air at the lower test load, although the maximum test load showed the maximum relative humidity at the dryer outlet. The desiccant wheel showed good performance in terms of moisture extraction rate and COPHP, but it showed poor performance in terms of the specific moisture extraction rate due to the high power consumption (around 2.6 kW) of the desiccant dehumidifier. The moisture extraction rate (MER) for all designs increased to a maximum value, followed by consistent decline. However, the maximum MER for the desiccant design exceeded those for the other designs.
Open AccessExperimental Analysis of a Heat Pump Dryer with an External Desiccant Wheel Dryer
This study examines the performance of three heat pump dryers: the original reference design, a modified drying chamber, and an external desiccant wheel design. Unlike most existing studies that normally adopt organic products as the drying materials, in this study we used moist sodium polyacrylate (Orbeez) as the drying material for consistent characterization of the heat pump performance. R-134a was adopted as the refrigerant for the heat pump system. The experiments were performed subject to different weights of Orbeez (drying material) at a constant volumetric flow rate of 100 m3/h. During experimentation, different parameters like the coefficient of performance (COPHP), drying rate, heat transfer rate by the condenser, moisture extraction rate, and specific moisture extraction rate were calculated. The average COPHP, mass transfer rate, heat transfer rate, MER, and SMER of the system were calculated as 3.9, 0.30 kg/s, 0.56 kW, 0.495 kg/h, and 1.614 kg/kWh, respectively. The maximum COP for the refrigeration system was achieved at lower test loads with the desiccant wheel. The moisture extraction rate for a lower test loading was higher than that for a higher test load due to the higher penetration of drying air at the lower test load, although the maximum test load showed the maximum relative humidity at the dryer outlet. The desiccant wheel showed good performance in terms of moisture extraction rate and COPHP, but it showed poor performance in terms of the specific moisture extraction rate due to the high power consumption (around 2.6 kW) of the desiccant dehumidifier. The moisture extraction rate (MER) for all designs increased to a maximum value, followed by consistent decline. However, the maximum MER for the desiccant design exceeded those for the other designs.
- Open Access
Performance Tests on a Novel Un-Finned Thermosyphon Heat Exchanger Requiring a Single Charge
A novel design of an unfinned thermosyphon HPHX having a continuous closed tube loop which requires only a single charge is proposed for industrial waste heat recovery. The HPHX consists of 9×17 straight copper tubes in a staggered arrangement connected by 144 U bends. Without fins, not only are the pressure drops of the cooling air flow limited, but the cost, weight and maintenance effort can be greatly reduced. The thermal performance of this novel thermosyphon HPHX was tested with water at a filling ratio of 40%. The evaporator section is immersed in hot silicone oil, while the condenser section is cooled by air flow. The heat transfer rate (Q) reaches 6.65 kW at a heating pool temperature of 150 °C and a cooling air flow rate (F) of 1600 CMH, when the HPHX attains maximum effective thermal conductivity of 12,798 W/m-K. An ε-NTU theoretical model for single-tube thermosyphons was formulated with the boiling and film condensation modelled by empirical correlations. This model predicts the total resistance Rtot of the HPHX, which decreases with Q and F, with a total error of less than ±10%.
Open AccessPerformance Tests on a Novel Un-Finned Thermosyphon Heat Exchanger Requiring a Single Charge
A novel design of an unfinned thermosyphon HPHX having a continuous closed tube loop which requires only a single charge is proposed for industrial waste heat recovery. The HPHX consists of 9×17 straight copper tubes in a staggered arrangement connected by 144 U bends. Without fins, not only are the pressure drops of the cooling air flow limited, but the cost, weight and maintenance effort can be greatly reduced. The thermal performance of this novel thermosyphon HPHX was tested with water at a filling ratio of 40%. The evaporator section is immersed in hot silicone oil, while the condenser section is cooled by air flow. The heat transfer rate (Q) reaches 6.65 kW at a heating pool temperature of 150 °C and a cooling air flow rate (F) of 1600 CMH, when the HPHX attains maximum effective thermal conductivity of 12,798 W/m-K. An ε-NTU theoretical model for single-tube thermosyphons was formulated with the boiling and film condensation modelled by empirical correlations. This model predicts the total resistance Rtot of the HPHX, which decreases with Q and F, with a total error of less than ±10%.
- Open Access
Performance of Commercially Open Refrigerated Showcases with and without Ice Storage—A Case Study
This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.
Open AccessPerformance of Commercially Open Refrigerated Showcases with and without Ice Storage—A Case Study
This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.
- Open Access
A Semi-Empirical Model for Predicting Frost Properties
In this study, a quantitative method for classifying the frost geometry is first proposed to substantiate a numerical model in predicting frost properties like density, thickness, and thermal conductivity. This method can recognize the crystal shape via linear programming of the existing map for frost morphology. By using this method, the frost conditions can be taken into account in a model to obtain the corresponding frost properties like thermal conductivity, frost thickness, and density for specific frost crystal. It is found that the developed model can predict the frost properties more accurately than the existing correlations. Specifically, the proposed model can identify the corresponding frost shape by a dimensionless temperature and the surface temperature. Moreover, by adopting the frost identification into the numerical model, the frost thickness can also be predicted satisfactorily. The proposed calculation method not only shows better predictive ability with thermal conductivities, but also gives good predictions for density and is especially accurate when the frost density is lower than 125 kg/m3. Yet, the predictive ability for frost density is improved by 24% when compared to the most accurate correlation available.
Open AccessA Semi-Empirical Model for Predicting Frost Properties
In this study, a quantitative method for classifying the frost geometry is first proposed to substantiate a numerical model in predicting frost properties like density, thickness, and thermal conductivity. This method can recognize the crystal shape via linear programming of the existing map for frost morphology. By using this method, the frost conditions can be taken into account in a model to obtain the corresponding frost properties like thermal conductivity, frost thickness, and density for specific frost crystal. It is found that the developed model can predict the frost properties more accurately than the existing correlations. Specifically, the proposed model can identify the corresponding frost shape by a dimensionless temperature and the surface temperature. Moreover, by adopting the frost identification into the numerical model, the frost thickness can also be predicted satisfactorily. The proposed calculation method not only shows better predictive ability with thermal conductivities, but also gives good predictions for density and is especially accurate when the frost density is lower than 125 kg/m3. Yet, the predictive ability for frost density is improved by 24% when compared to the most accurate correlation available.
- Open Access
Non-Uniform Three-Dimensional Pulsating Heat Pipe for Anti-Gravity High-Flux Applications
This study proposes a novel high-flux pulsating heat pipe that can lift the major constraint of the conventional pulsating heat pipe (PHP) which is unable to function properly upon anti-gravity operations. The proposed PHP introduces additional unbalance force via uneven tube diameter/geometry in the adiabatic sections to tailor the problem in anti-gravity operation. The design contains a three-dimensional configuration circuitry with compact arrangement tubes on the evaporator and condenser. Through this design, the non-uniform three-dimensional pulsating heat pipe (3D-PHP) manipulates the uneven inner diameters of the adiabatic sections to form uneven vapor/liquid distributions in the adiabatic sections to yield a unitary flow pattern that is able to withstand a much higher input power. The present PHP uses methanol as working fluid, with 38% volumetric filling ratio, and has a high-flux of 22.9 W/cm2 and a low the thermal resistance ratio (Ranti-gravity/Rgravity-assisted) of 1.05 when the input power is 800 W. Both the heat flux and thermal resistance ratio for the proposed design are far better than the existing literature.
Open AccessNon-Uniform Three-Dimensional Pulsating Heat Pipe for Anti-Gravity High-Flux Applications
This study proposes a novel high-flux pulsating heat pipe that can lift the major constraint of the conventional pulsating heat pipe (PHP) which is unable to function properly upon anti-gravity operations. The proposed PHP introduces additional unbalance force via uneven tube diameter/geometry in the adiabatic sections to tailor the problem in anti-gravity operation. The design contains a three-dimensional configuration circuitry with compact arrangement tubes on the evaporator and condenser. Through this design, the non-uniform three-dimensional pulsating heat pipe (3D-PHP) manipulates the uneven inner diameters of the adiabatic sections to form uneven vapor/liquid distributions in the adiabatic sections to yield a unitary flow pattern that is able to withstand a much higher input power. The present PHP uses methanol as working fluid, with 38% volumetric filling ratio, and has a high-flux of 22.9 W/cm2 and a low the thermal resistance ratio (Ranti-gravity/Rgravity-assisted) of 1.05 when the input power is 800 W. Both the heat flux and thermal resistance ratio for the proposed design are far better than the existing literature.