Mingjun Xue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mingjun Xue has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chen Qi
China Electric Power Research Institute
1 shared publication Chunlin Yu
Guodian Nanjing Automation Company Ltd., Nanjing, China
1 shared publication- Fufeng Chen
School of Electrical Engineering, Southeast University, Nanjing, China
1 shared publication - Huazhen Cao
Guangdong Power Grid Corporation Planning Research Center, Guangzhou, China
1 shared publication Lei Zou
Guodian Nanjing Automation Company Ltd., Nanjing, China
1 shared publicationLiming Yang
Guodian Nanjing Automation Company Ltd., Nanjing, China
1 shared publication
Latest Publications
- Open Access
- 23 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 58789-58800
Multi-Terminal Wireless Differential Protection Method for Offshore Wind Power Collection Lines
The development of offshore wind power is a crucial step in China’s energy transition and the achievement of carbon peaking and carbon neutrality goals. This paper first introduces a wireless communication technology for independent networking. Its applicability in the field of relay protection is analyzed, and a security encryption scheme for its use in relay protection services is designed. Considering the primary wiring form and protection function configuration of offshore wind power, a multi-terminal wireless differential protection method suitable for offshore wind power collection lines is proposed, achieving synchronization error less than 3° and typical delay of wireless self-organizing network communication less than 12ms. Utilizing multi-terminal data synchronization technology and differential protection algorithms, a scheme for fault isolation and recovery of non-faulty wind turbines is established, thereby achieving minimal range isolation of offshore wind power collection line faults and precise fault section location. The action time of multi-terminal differential protection is less than 40ms. Finally, experimental results confirm that this technology’s various metrics satisfy the demands of engineering applications and hold promotional value, offering a reference for the practical application of wireless communication technology in offshore wind power collection line protection services.
- 23 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 58789-58800
Open AccessMulti-Terminal Wireless Differential Protection Method for Offshore Wind Power Collection Lines
The development of offshore wind power is a crucial step in China’s energy transition and the achievement of carbon peaking and carbon neutrality goals. This paper first introduces a wireless communication technology for independent networking. Its applicability in the field of relay protection is analyzed, and a security encryption scheme for its use in relay protection services is designed. Considering the primary wiring form and protection function configuration of offshore wind power, a multi-terminal wireless differential protection method suitable for offshore wind power collection lines is proposed, achieving synchronization error less than 3° and typical delay of wireless self-organizing network communication less than 12ms. Utilizing multi-terminal data synchronization technology and differential protection algorithms, a scheme for fault isolation and recovery of non-faulty wind turbines is established, thereby achieving minimal range isolation of offshore wind power collection line faults and precise fault section location. The action time of multi-terminal differential protection is less than 40ms. Finally, experimental results confirm that this technology’s various metrics satisfy the demands of engineering applications and hold promotional value, offering a reference for the practical application of wireless communication technology in offshore wind power collection line protection services.
- Open Access
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 86002-86012
Stabilized Control for Power Electronics Transformer-Based Grid-Tied Inverter System
The stability of a grid-tied inverter system will be compromised in weak grid conditions. In order to address this problem, researchers have proposed using a power electronics transformer (PET) to connect inverters and the grid. By adjusting the controller parameters or control strategy, the output impedance of the PET low voltage (LV) converter can be varied to improve the system stability. This paper establishes impedance models of the PET-based grid-tied inverter system and evaluates the stability of the system using the generalized Nyquist criterion. The impact of the variety of control parameters on the system stability is then analyzed. To improve the stability of the system, two stabilized control strategies, namely virtual impedance and digital filter-based methods are proposed. Finally, the effectiveness of these strategies is evaluated through simulations and experiments.
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 86002-86012
Open AccessStabilized Control for Power Electronics Transformer-Based Grid-Tied Inverter System
The stability of a grid-tied inverter system will be compromised in weak grid conditions. In order to address this problem, researchers have proposed using a power electronics transformer (PET) to connect inverters and the grid. By adjusting the controller parameters or control strategy, the output impedance of the PET low voltage (LV) converter can be varied to improve the system stability. This paper establishes impedance models of the PET-based grid-tied inverter system and evaluates the stability of the system using the generalized Nyquist criterion. The impact of the variety of control parameters on the system stability is then analyzed. To improve the stability of the system, two stabilized control strategies, namely virtual impedance and digital filter-based methods are proposed. Finally, the effectiveness of these strategies is evaluated through simulations and experiments.