Swapnil Ratnakar Mane
Swapnil Ratnakar Mane has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ashok Pandarinath Tadamalle
SVKM’s Dwarkadas J. Sanghvi College of Engineering, Mumbai, India
1 shared publication - Prakash Gopalrao Kadam
JSPM’s Jayawantrao Sawant College of Engineering, Pune, India
1 shared publication - Prakash Marotrao Kadam
JSPM’s Jayawantrao Sawant College of Engineering, Pune, India
1 shared publication - Prashant Ingle
Saraswati College of Engineering, Navi Mumbai, India
1 shared publication - R. V. Kale
Head of Department Department of Mechanical Engineering MCT's Rajiv Gandhi Institute of Technology Mumbai Maharashtra India
1 shared publication Rajesh Kale
Department of Mechanical Engineering, Rajiv Gandhi Institute of Technology, Mumbai, 400053, India
1 shared publication
Latest Publications
- Open Access
- 26 September 2026
- Published by Springer Nature in Discover Energy
- Vol. 6 (1) , 72
A sustainable solar water heating using integration of quality function deployment
- 26 September 2026
- Published by Springer Nature in Discover Energy
- Vol. 6 (1) , 72
Open AccessA sustainable solar water heating using integration of quality function deployment
- 19 August 2026
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (42) , 43514-43535
Brs-Hmm: Bobcat Optimized Resnet50V2-Swint Framework for Analyzing the Powder Behavior of Aa7075/Al2O3/Graphene in Friction Stir Additive Manufacturing
- 19 August 2026
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (42) , 43514-43535
Brs-Hmm: Bobcat Optimized Resnet50V2-Swint Framework for Analyzing the Powder Behavior of Aa7075/Al2O3/Graphene in Friction Stir Additive Manufacturing
- Open Access
- 1 January 2024
- Published by Engineering, Project, and Production Management (EPPM) in Journal of Engineering, Project, and Production Management
- Vol. 14 (1) , 1-11
Experimental Investigation and CFD Analysis of Different Diameter Evacuated Tube Solar Water Heater
The share of renewable energy share in India's energy mix of India has been increasing recently owing to the promotion and implementation of various government policies that promote the use of renewable sources of energy, depleting fossil fuel levels, increasing fuel prices, and stringent laws for emission reduction worldwide. The increase in the use of solar-evacuated-tube-collector-based domestic water heating is the result of this transition from conventional to nonconventional sources of energy. The recent urban agglomeration is challenging to install these solar water heaters in every household because the roof space is limited. Space reduction can be achieved by reducing the collector area by varying the diameter of the evacuated tubes. This study used a single tube and tank arrangement model with a fixed inclination to achieve a thermosyphon effect in a solar water heating system with three different diameter configurations of 48 mm, 54 mm, and 72 mm, with a tube measuring 1800 mm in length. Thermal assessment of the thermosyphon-based evacuated tube-solar water heater using the ANSYS CFD simulation software involves measuring the temperature at three different positions in the tank to study the thermosyphon initialization. This study signifies that the 72-mm-diameter evacuated tube is more capable of initializing the thermosyphon effect in the system. Nevertheless, the final temperature of the system is better achieved in the 48-mm-diameter evacuated tube.
- 1 January 2024
- Published by Engineering, Project, and Production Management (EPPM) in Journal of Engineering, Project, and Production Management
- Vol. 14 (1) , 1-11
Open AccessExperimental Investigation and CFD Analysis of Different Diameter Evacuated Tube Solar Water Heater
The share of renewable energy share in India's energy mix of India has been increasing recently owing to the promotion and implementation of various government policies that promote the use of renewable sources of energy, depleting fossil fuel levels, increasing fuel prices, and stringent laws for emission reduction worldwide. The increase in the use of solar-evacuated-tube-collector-based domestic water heating is the result of this transition from conventional to nonconventional sources of energy. The recent urban agglomeration is challenging to install these solar water heaters in every household because the roof space is limited. Space reduction can be achieved by reducing the collector area by varying the diameter of the evacuated tubes. This study used a single tube and tank arrangement model with a fixed inclination to achieve a thermosyphon effect in a solar water heating system with three different diameter configurations of 48 mm, 54 mm, and 72 mm, with a tube measuring 1800 mm in length. Thermal assessment of the thermosyphon-based evacuated tube-solar water heater using the ANSYS CFD simulation software involves measuring the temperature at three different positions in the tank to study the thermosyphon initialization. This study signifies that the 72-mm-diameter evacuated tube is more capable of initializing the thermosyphon effect in the system. Nevertheless, the final temperature of the system is better achieved in the 48-mm-diameter evacuated tube.