Xiao Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiao Zhou has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zhen Cheng
Tsinghua University
2 shared publications - Chaoyi Wu
Shanghai Artificial Intelligence Laboratory
1 shared publication - Miao Gu
Department of Automation, Tsinghua University, Beijing 100084, China
1 shared publication - Shihong Wang
School of Biomedical Engineering, Tsinghua University, Beijing 100084, China
1 shared publication - Weidi Xie
School of Artificial Intelligence, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Weiguo Hu
Department of Automation, Tsinghua University, Beijing 100084, China
1 shared publication
Latest Publications
- Open Access
- 3 December 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (12) , 1379
Small Object Localization with 90% Annotation Reduction by Positive-Unlabeled Learning
Small object localization is one of the most challenging tasks owing to the poor visual appearance and noisy representation caused by the intrinsic structure of small targets. Recent advances in localizing small objects are mainly dependent on regression-based counting approaches, which require considerable annotations for training. As a contrast, human learners can quickly master labeling skills from only a few annotation examples. In this paper, we attempt to simulate this training mechanism and propose a novel positive-unlabeled (PU) learning based approach that can localize small objects by learning from partial point annotations. We evaluate our approach on five typical datasets of small objects involving a single cell, an animal/insect, and human crowds. Quantitative experimental results show that our approach has achieved inspiring localization performance (F1 score > 0.75) even under the supervision of less than 10% of the overall point annotations. This approach paves the way for low-annotation-cost single-cell analysis within microfluidic droplets.
- 3 December 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (12) , 1379
Open AccessSmall Object Localization with 90% Annotation Reduction by Positive-Unlabeled Learning
Small object localization is one of the most challenging tasks owing to the poor visual appearance and noisy representation caused by the intrinsic structure of small targets. Recent advances in localizing small objects are mainly dependent on regression-based counting approaches, which require considerable annotations for training. As a contrast, human learners can quickly master labeling skills from only a few annotation examples. In this paper, we attempt to simulate this training mechanism and propose a novel positive-unlabeled (PU) learning based approach that can localize small objects by learning from partial point annotations. We evaluate our approach on five typical datasets of small objects involving a single cell, an animal/insect, and human crowds. Quantitative experimental results show that our approach has achieved inspiring localization performance (F1 score > 0.75) even under the supervision of less than 10% of the overall point annotations. This approach paves the way for low-annotation-cost single-cell analysis within microfluidic droplets.
- 29 November 2024
- Published by Springer Nature
- p. 345-362
Knowledge-Enhanced Visual-Language Pretraining for Computational Pathology
- 29 November 2024
- Published by Springer Nature
- p. 345-362
Knowledge-Enhanced Visual-Language Pretraining for Computational Pathology
- Open Access
- 15 August 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (8) , 821
WSCNet: Biomedical Image Recognition for Cell Encapsulated Microfluidic Droplets
Microfluidic droplets accommodating a single cell as independent microreactors are frequently demanded for single-cell analysis of phenotype and genotype. However, challenges exist in identifying and reducing the covalence probability (following Poisson’s distribution) of more than two cells encapsulated in one droplet. It is of great significance to monitor and control the quantity of encapsulated content inside each droplet. We demonstrated a microfluidic system embedded with a weakly supervised cell counting network (WSCNet) to generate microfluidic droplets, evaluate their quality, and further recognize the locations of encapsulated cells. Here, we systematically verified our approach using encapsulated droplets from three different microfluidic structures. Quantitative experimental results showed that our approach can not only distinguish droplet encapsulations (F1 score > 0.88) but also locate each cell without any supervised location information (accuracy > 89%). The probability of a “single cell in one droplet” encapsulation is systematically verified under different parameters, which shows good agreement with the distribution of the passive method (Residual Sum of Squares, RSS < 0.5). This study offers a comprehensive platform for the quantitative assessment of encapsulated microfluidic droplets.
- 15 August 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (8) , 821
Open AccessWSCNet: Biomedical Image Recognition for Cell Encapsulated Microfluidic Droplets
Microfluidic droplets accommodating a single cell as independent microreactors are frequently demanded for single-cell analysis of phenotype and genotype. However, challenges exist in identifying and reducing the covalence probability (following Poisson’s distribution) of more than two cells encapsulated in one droplet. It is of great significance to monitor and control the quantity of encapsulated content inside each droplet. We demonstrated a microfluidic system embedded with a weakly supervised cell counting network (WSCNet) to generate microfluidic droplets, evaluate their quality, and further recognize the locations of encapsulated cells. Here, we systematically verified our approach using encapsulated droplets from three different microfluidic structures. Quantitative experimental results showed that our approach can not only distinguish droplet encapsulations (F1 score > 0.88) but also locate each cell without any supervised location information (accuracy > 89%). The probability of a “single cell in one droplet” encapsulation is systematically verified under different parameters, which shows good agreement with the distribution of the passive method (Residual Sum of Squares, RSS < 0.5). This study offers a comprehensive platform for the quantitative assessment of encapsulated microfluidic droplets.