Chandani Chitrakar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chandani Chitrakar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ankit R. Parikh
Department of Mechanical Engineering The University of Texas at Dallas Richardson TX 75080 USA
2 shared publications - Joseph Jewell Pancrazio
The University of Texas at Dallas
2 shared publications - Melanie Ecker
Department of Biomedical Engineering, University of North Texas, Denton, TX 76203, USA
2 shared publications - Ovidio Rodriguez‐Lopez
Department of Electrical and Computer Engineering The University of Texas at Dallas Richardson TX 75080 USA
2 shared publications - Pedro Emanuel Rocha-Flores
Biomedical Engineering, University of Texas at Dallas, Richardson, TX
2 shared publications - Walter Voit
Department of Mechanical Engineering University of Texas at Dallas Richardson Texas USA
2 shared publications
Latest Publications
- 4 December 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (6)
Softening, Conformable, and Stretchable Conductors for Implantable Bioelectronics Interfaces
Neural implantable devices serve as electronic interfaces facilitating communication between the body and external electronic systems. These bioelectronic systems ideally possess stable electrical conductivity, flexibility, and stretchability to accommodate dynamic movements within the body. However, achieving both high electrical conductivity and mechanical compatibility remains a challenge. Effective electrical conductors tend to be rigid and stiff, leading to a substantial mechanical mismatch with bodily tissues. On the other hand, highly stretchable polymers, while mechanically compatible, often suffer from limited compatibility with lithography techniques and reduced electrical stability. Therefore, there exists a pressing need to develop electromechanically stable neural interfaces that enable precise communication with biological tissues. In this study, a polymer that is softening, flexible, conformal, and compatible with lithography to microfabricate perforated thin‐film architectures is utilized. These architectures offer stretchability and improved mechanical compatibility. Three distinct geometries are evaluated both mechanically and electrically under in vitro conditions that simulate physiological environments. Notably, the Peano structure demonstrates minimal changes in resistance, varying less than 1.5× even when subjected to ≈150% strain. Furthermore, devices exhibit a maximum mechanical elongation before fracture, reaching 220%. Finally, the application of multi‐electrode spinal cord leads employing titanium nitride for neural stimulation in rat models is demonstrated.
- 4 December 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (6)
Softening, Conformable, and Stretchable Conductors for Implantable Bioelectronics Interfaces
Neural implantable devices serve as electronic interfaces facilitating communication between the body and external electronic systems. These bioelectronic systems ideally possess stable electrical conductivity, flexibility, and stretchability to accommodate dynamic movements within the body. However, achieving both high electrical conductivity and mechanical compatibility remains a challenge. Effective electrical conductors tend to be rigid and stiff, leading to a substantial mechanical mismatch with bodily tissues. On the other hand, highly stretchable polymers, while mechanically compatible, often suffer from limited compatibility with lithography techniques and reduced electrical stability. Therefore, there exists a pressing need to develop electromechanically stable neural interfaces that enable precise communication with biological tissues. In this study, a polymer that is softening, flexible, conformal, and compatible with lithography to microfabricate perforated thin‐film architectures is utilized. These architectures offer stretchability and improved mechanical compatibility. Three distinct geometries are evaluated both mechanically and electrically under in vitro conditions that simulate physiological environments. Notably, the Peano structure demonstrates minimal changes in resistance, varying less than 1.5× even when subjected to ≈150% strain. Furthermore, devices exhibit a maximum mechanical elongation before fracture, reaching 220%. Finally, the application of multi‐electrode spinal cord leads employing titanium nitride for neural stimulation in rat models is demonstrated.
- 15 August 2023
- Published by Springer Nature in MRS Communications
- Vol. 13 (5) , 892-900
Softening and flexible hybrid electronics integration for biomedical applications
- 15 August 2023
- Published by Springer Nature in MRS Communications
- Vol. 13 (5) , 892-900
Softening and flexible hybrid electronics integration for biomedical applications