Sichao Pan
Research Subjects
Sichao Pan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Libo Ma
School of Electrical and Electronic Engineering, North China Electric Power University, Baoding, China
2 shared publications Hongshan Zhao
School of Electrical and Electronic Engineering North China Electric Power University Baoding China
1 shared publication- Hongshan Zhao
North China Electric Power University
1 shared publication - Jiancun Liu
Tianjin Key Laboratory of New Energy Power Conversion, Transmission and Intelligent Control, Tianjin University of Technology, Tianjin 300384, China
1 shared publication - Ranran An
Electric Power Research Institute, Guangdong Power Grid Co., Ltd., Guangzhou 510050, China
1 shared publication - Wenlong Yang
School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin 300384, China
1 shared publication
Latest Publications
- Open Access
Frequency Modulation Capability Improvement Method of Offshore Wind Farms Based on Energy Storage Devices
Installing energy storage devices can improve the frequency modulation ability of offshore wind farms to participate in the grid. The lifecycle and wear of energy storage devices are significantly influenced by ambient temperature, charge and discharge rates, cycle depths, and operating environments. To extend the lifecycle and reduce the replacement frequency of these devices, their operation mode must be carefully considered. However, existing energy storage optimization configurations rarely consider these factors, particularly when addressing the frequency stability of offshore wind power systems. To address this gap, an optimization method is proposed for energy storage allocation that incorporates system frequency support, energy storage cost, and the devices’ lifecycle and degradation. This approach ensures a reasonable and efficient allocation of energy storage.
Open AccessFrequency Modulation Capability Improvement Method of Offshore Wind Farms Based on Energy Storage Devices
Installing energy storage devices can improve the frequency modulation ability of offshore wind farms to participate in the grid. The lifecycle and wear of energy storage devices are significantly influenced by ambient temperature, charge and discharge rates, cycle depths, and operating environments. To extend the lifecycle and reduce the replacement frequency of these devices, their operation mode must be carefully considered. However, existing energy storage optimization configurations rarely consider these factors, particularly when addressing the frequency stability of offshore wind power systems. To address this gap, an optimization method is proposed for energy storage allocation that incorporates system frequency support, energy storage cost, and the devices’ lifecycle and degradation. This approach ensures a reasonable and efficient allocation of energy storage.
- Open Access
- 29 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (9-10) , 1597-1610
Research on temperature control of proton exchange membrane electrolysis cell based on MO‐TD3
To solve the problem of temperature control in proton exchange membrane electrolytic cell (PEMEC), this paper presents a temperature control method based on multi‐experience pool probability playback and Ornstein‐Uhlenbeck noise‐twin delay depth deterministic strategy gradient. Firstly, considering the influence of water supply, anode and cathode pressure, and natural heat dissipation on temperature, a refined thermal model of PEMEC is established and transformed into a Markov model under the framework of deep reinforcement learning (DRL). Then, to solve the training instability and poor control effect of DRL caused by inertia delay of the PEMEC temperature control system, multi‐empirical pool probability playback and Ornstein‐Uhlenbeck random process noise techniques are introduced on the basis of the traditional DRL method. Finally, the simulation and hardware‐in‐the‐loop experience results show that the proposed method outperforms other advanced methods.
- 29 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (9-10) , 1597-1610
Open AccessResearch on temperature control of proton exchange membrane electrolysis cell based on MO‐TD3
To solve the problem of temperature control in proton exchange membrane electrolytic cell (PEMEC), this paper presents a temperature control method based on multi‐experience pool probability playback and Ornstein‐Uhlenbeck noise‐twin delay depth deterministic strategy gradient. Firstly, considering the influence of water supply, anode and cathode pressure, and natural heat dissipation on temperature, a refined thermal model of PEMEC is established and transformed into a Markov model under the framework of deep reinforcement learning (DRL). Then, to solve the training instability and poor control effect of DRL caused by inertia delay of the PEMEC temperature control system, multi‐empirical pool probability playback and Ornstein‐Uhlenbeck random process noise techniques are introduced on the basis of the traditional DRL method. Finally, the simulation and hardware‐in‐the‐loop experience results show that the proposed method outperforms other advanced methods.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Spatial and Temporal Attention-Enabled Transformer Network for Multivariate Short-Term Residential Load Forecasting
Short-term residential load forecasting (STRLF) is critical for safe and stable operation of the microgrid system. Due to shred conditions such as temperature and holiday impacts, households in the same region may exhibit similar consumption patterns. However, existing STRLF methods focus mainly on exploring the temporal patterns of a single household; the spatial correlations between multiple households are generally ignored. To address this challenge, a spatial and temporal attention-enabled transformer model, STformer, is proposed to extract the dynamic spatial and nonlinear temporal correlations between residential units and perform joint predictions of multivariate residential loads. The combination of improved temporal attention and spatial attention mechanisms allows the proposed method to capture complex spatial and temporal factors without prior geographical information. The Monte Carlo (MC) dropout method is utilized to further extend the proposed model to multi-task residential probabilistic load forecasting. Compared to Transformer, the proposed model improves the point forecast accuracy of individual New York and Los Angeles by 16.54% and 6.95%, respectively; and the combined point forecast accuracy by 22.46% and 11.86%. In addition, the proposed model improved the residential probabilistic load prediction accuracy by 10.21% and 11.07% in New York and Los Angeles, respectively, compared to SGPR.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Spatial and Temporal Attention-Enabled Transformer Network for Multivariate Short-Term Residential Load Forecasting
Short-term residential load forecasting (STRLF) is critical for safe and stable operation of the microgrid system. Due to shred conditions such as temperature and holiday impacts, households in the same region may exhibit similar consumption patterns. However, existing STRLF methods focus mainly on exploring the temporal patterns of a single household; the spatial correlations between multiple households are generally ignored. To address this challenge, a spatial and temporal attention-enabled transformer model, STformer, is proposed to extract the dynamic spatial and nonlinear temporal correlations between residential units and perform joint predictions of multivariate residential loads. The combination of improved temporal attention and spatial attention mechanisms allows the proposed method to capture complex spatial and temporal factors without prior geographical information. The Monte Carlo (MC) dropout method is utilized to further extend the proposed model to multi-task residential probabilistic load forecasting. Compared to Transformer, the proposed model improves the point forecast accuracy of individual New York and Los Angeles by 16.54% and 6.95%, respectively; and the combined point forecast accuracy by 22.46% and 11.86%. In addition, the proposed model improved the residential probabilistic load prediction accuracy by 10.21% and 11.07% in New York and Los Angeles, respectively, compared to SGPR.