Johanna E. Camara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johanna E. Camara has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Elena Shiao Ching Wood4 shared publications
- Ashley Beasley-Green
National Institute of Standards and Technology
3 shared publications - Hubert W. Vesper
Centers for Disease Control and Prevention, Atlanta, GA, USA
3 shared publications - Vincent Delatour
Laboratoire National de métrologie et d’Essais (LNE), Paris, France
3 shared publications Adam J. Kuszak
Office of Dietary Supplements (ODS), National Institutes of Health (NIH), Bethesda, USA
2 shared publications- Blaza Toman
Information Technology Laboratory National Institute of Standards and Technology Boulder CO 80305 USA
2 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- p. 1-28
Standard Reference Material (SRM®) 1950 metabolites in frozen human plasma—use, impact, lessons learned, and future perspectives
In 2011, the National Institute of Standards and Technology (NIST), in collaboration with the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) at the National Institutes of Health (NIH), issued Standard Reference Material (SRM)® 1950 Metabolites in Frozen Human Plasma to support metabolomics measurements. This critical review traces the development of SRM 1950 and assesses its use and impact over the past 15 years. To evaluate its impact, we reviewed more than 400 technical papers demonstrating its broad adoption in analytical, metabolomic, and lipidomic research. While SRM 1950 included certified values for selected amino acids, fatty acids, and clinical markers (such as cholesterol, glucose, 25-hydroxyvitamin D, and steroid hormones), its greatest impact has been as a shared material for interlaboratory comparisons and the community-generated consensus or target values established for the broad scope of compounds commonly measured in metabolomic and lipidomic studies. Many studies used SRM 1950 to validate analytical methods against NIST-certified values, while over 50 papers provided extensive qualitative and quantitative characterization and compared their results with interlaboratory consensus values and other studies to assess method and platform performance. The success of SRM 1950 helped to catalyze the development of additional NIST reference materials (RMs) for the “omics” communities and highlighted the potential of existing clinical and environmental matrix SRMs for further untargeted characterization and community reporting. Based on this literature review, we offer recommendations to expand the use and impact of the next generation of SRM 1950 and other SRMs/RMs intended and/or useful for untargeted analyses. Graphical Abstract
- 16 October 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- p. 1-28
Open AccessStandard Reference Material (SRM®) 1950 metabolites in frozen human plasma—use, impact, lessons learned, and future perspectives
In 2011, the National Institute of Standards and Technology (NIST), in collaboration with the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) at the National Institutes of Health (NIH), issued Standard Reference Material (SRM)® 1950 Metabolites in Frozen Human Plasma to support metabolomics measurements. This critical review traces the development of SRM 1950 and assesses its use and impact over the past 15 years. To evaluate its impact, we reviewed more than 400 technical papers demonstrating its broad adoption in analytical, metabolomic, and lipidomic research. While SRM 1950 included certified values for selected amino acids, fatty acids, and clinical markers (such as cholesterol, glucose, 25-hydroxyvitamin D, and steroid hormones), its greatest impact has been as a shared material for interlaboratory comparisons and the community-generated consensus or target values established for the broad scope of compounds commonly measured in metabolomic and lipidomic studies. Many studies used SRM 1950 to validate analytical methods against NIST-certified values, while over 50 papers provided extensive qualitative and quantitative characterization and compared their results with interlaboratory consensus values and other studies to assess method and platform performance. The success of SRM 1950 helped to catalyze the development of additional NIST reference materials (RMs) for the “omics” communities and highlighted the potential of existing clinical and environmental matrix SRMs for further untargeted characterization and community reporting. Based on this literature review, we offer recommendations to expand the use and impact of the next generation of SRM 1950 and other SRMs/RMs intended and/or useful for untargeted analyses. Graphical Abstract
- 19 November 2025
- Published by National Institute of Standards and Technology (NIST)
Extent-of-equivalence assessment of certified reference materials for albumin and creatinine in human urine
Accurate urine albumin test results are crucial for diagnosing and managing kidney disease. Toensure accuracy and consistency, clinical lab results need to be standardized. This can beachieved by establishing a calibration hierarchy that links clinical results to the foundational unitof measure, the International System of Units (SI). The National Institute of Standards andTechnology (NIST) and the Health Sciences Authority (HSA), Singapore, have developed twocertified reference materials (CRMs) for albumin and creatinine in human urine. An extent-ofequivalence assessment was performed to compare the certified values of urine albumin andcreatinine in the two human urine CRMs (NIST SRM 3666 and HRM-3004A). The overlap observedin the equivalence assessment between the measured [Xi ± U95(Xi)] and certified[Ci ± U95(Ci)] intervals indicate that the intervals agree within their assigned uncertainties withabout a 95 % level of confidence. Therefore, the CRMs were deemed equivalent at a 95 % levelof confidence for measuring urine albumin and creatinine. The equivalence of these CRMsensures that their interchangeable use in a calibration hierarchy does not introduce additionalbias, thereby maintaining the integrity of the calibration hierarchy and ensuring thatmeasurement results remain reliable and without significant impacts on uncertainty or quality.By establishing a robust calibration hierarchy for urine albumin and creatinine measurements,we can enhance the reliability and accuracy of clinical laboratory measurements for kidneydisease diagnosis and monitoring, ultimately leading to better patient outcomes and moreeffective healthcare management.
- 19 November 2025
- Published by National Institute of Standards and Technology (NIST)
Extent-of-equivalence assessment of certified reference materials for albumin and creatinine in human urine
Accurate urine albumin test results are crucial for diagnosing and managing kidney disease. Toensure accuracy and consistency, clinical lab results need to be standardized. This can beachieved by establishing a calibration hierarchy that links clinical results to the foundational unitof measure, the International System of Units (SI). The National Institute of Standards andTechnology (NIST) and the Health Sciences Authority (HSA), Singapore, have developed twocertified reference materials (CRMs) for albumin and creatinine in human urine. An extent-ofequivalence assessment was performed to compare the certified values of urine albumin andcreatinine in the two human urine CRMs (NIST SRM 3666 and HRM-3004A). The overlap observedin the equivalence assessment between the measured [Xi ± U95(Xi)] and certified[Ci ± U95(Ci)] intervals indicate that the intervals agree within their assigned uncertainties withabout a 95 % level of confidence. Therefore, the CRMs were deemed equivalent at a 95 % levelof confidence for measuring urine albumin and creatinine. The equivalence of these CRMsensures that their interchangeable use in a calibration hierarchy does not introduce additionalbias, thereby maintaining the integrity of the calibration hierarchy and ensuring thatmeasurement results remain reliable and without significant impacts on uncertainty or quality.By establishing a robust calibration hierarchy for urine albumin and creatinine measurements,we can enhance the reliability and accuracy of clinical laboratory measurements for kidneydisease diagnosis and monitoring, ultimately leading to better patient outcomes and moreeffective healthcare management.
- 2 September 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 3666 :
The National Institute of Standards and Technology (NIST) Standard Reference Material® (SRM®) 3666 Albumin and Creatinine in Frozen Human Urine is a secondary measurement standard for albumin and creatinine in human urine. The material is intended for use in a calibration hierarchy, in the validation of measurement procedures, or as quality control material for the determination of albumin, creatinine, or the albumin-to-creatinine ratio (ACR) in human urine. A unit of SRM 3666 consists of four (4) vials of frozen pooled human urine with four (4) different levels (Level I to Level IV) of endogenous albumin determined using the NIST candidate reference measurement procedure (RMP) for albumin in urine [1]; and creatinine determined using a modification of the NIST RMP for creatinine in serum [2]. The certified values and associated uncertainties for albumin and creatinine were used to calculate the ACR for each level (Level I to Level IV). This publication documents the production, measurement processes, results, and statistical evaluations involved in the production and certification of SRM 3666.
- 2 September 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 3666 :
The National Institute of Standards and Technology (NIST) Standard Reference Material® (SRM®) 3666 Albumin and Creatinine in Frozen Human Urine is a secondary measurement standard for albumin and creatinine in human urine. The material is intended for use in a calibration hierarchy, in the validation of measurement procedures, or as quality control material for the determination of albumin, creatinine, or the albumin-to-creatinine ratio (ACR) in human urine. A unit of SRM 3666 consists of four (4) vials of frozen pooled human urine with four (4) different levels (Level I to Level IV) of endogenous albumin determined using the NIST candidate reference measurement procedure (RMP) for albumin in urine [1]; and creatinine determined using a modification of the NIST RMP for creatinine in serum [2]. The certified values and associated uncertainties for albumin and creatinine were used to calculate the ACR for each level (Level I to Level IV). This publication documents the production, measurement processes, results, and statistical evaluations involved in the production and certification of SRM 3666.
- 14 May 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material®s 3672a & 3673a :
Standard Reference Material (SRM) 3672a Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673a Organic Contaminants in Non-Smokers’ Urine (Frozen) are intended for use in evaluating analytical methods for the determination of selected naturally-occurring smoking-related compounds and metabolites in urine. The development of SRMs 3672a and 3673a was a collaboration between the National Institute of Standards and Technology (NIST) and the Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC). This publication documents the production, analytical methods, and statistics used to characterize these products.
- 14 May 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material®s 3672a & 3673a :
Standard Reference Material (SRM) 3672a Organic Contaminants in Smokers’ Urine (Frozen) and SRM 3673a Organic Contaminants in Non-Smokers’ Urine (Frozen) are intended for use in evaluating analytical methods for the determination of selected naturally-occurring smoking-related compounds and metabolites in urine. The development of SRMs 3672a and 3673a was a collaboration between the National Institute of Standards and Technology (NIST) and the Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC). This publication documents the production, analytical methods, and statistics used to characterize these products.
- 13 March 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material® 965c glucose in frozen human serum
Standard Reference Material (SRM) 965c Glucose in Frozen Human Serum is intended for use in validating methods for the determination of glucose in human serum and plasma. A unit of SRM 965c consists of three ampoules each of four materials: Level 1, Level 2, Level 3, and Level 4. Each ampoule contains approximately 1.0 mL of frozen serum. The value assignment of SRM 965c was a collaboration between the National Institute of Standards and Technology (NIST) and the Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC). This publication documents the production, analytical methods, and computations involved in characterizing this product.
- 13 March 2025
- Published by National Institute of Standards and Technology (NIST)
Certification of Standard Reference Material® 965c glucose in frozen human serum
Standard Reference Material (SRM) 965c Glucose in Frozen Human Serum is intended for use in validating methods for the determination of glucose in human serum and plasma. A unit of SRM 965c consists of three ampoules each of four materials: Level 1, Level 2, Level 3, and Level 4. Each ampoule contains approximately 1.0 mL of frozen serum. The value assignment of SRM 965c was a collaboration between the National Institute of Standards and Technology (NIST) and the Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC). This publication documents the production, analytical methods, and computations involved in characterizing this product.
- 4 November 2024
- Published by National Institute of Standards and Technology (NIST)
Practical guide for collecting feedback from NIST SRM & RM users :
One way NIST ensures that measurements are accurate and compatible is by certifying and providing over 1 300 Standard Reference Materials® (SRM®) with well-characterized composition, properties, or both. Customers use these materials to calibrate instruments, verify specific measurements, and develop new measurement methods. However, sales data alone is insufficient to determine when to update or restock these materials. Collecting customer data systematically can help make informed decisions and reduce waste and missed opportunities. In 2023, NIST SRM 1950, Metabolites in Frozen Human Plasma, had a supply remaining for approximately 4 years. A decision was needed on whether to renew SRM 1950 and/or develop new reference materials in the coming years–a process that typically takes 5 to 7 years. The Information Technology Laboratory (ITL) Information Access Division (IAD) and the Material Measurement Laboratory (MML) Chemical Sciences Division (CSD) collaborated to conduct an online customer and stakeholder survey following established and rigorous methodology and process. The survey development process and the artifacts produced can serve as a model with templates for future measurement services projects to gather market research data and inform planning and development in a repeatable and consistent way. This document provides a practical, step-by-step guide to the survey development process for collecting feedback from NIST reference materials users and customers. It aims to provide concise guidance, complete with artifacts and templates, using the 2023 NIST SRM 1950 customer feedback survey project to illustrate how to conduct a user feedback survey following an 8-step survey development process. This practical guide outlines a process for developing surveys incorporating stakeholder feedback into decision-making for new measurement service projects, which can be reused or adapted.
- 4 November 2024
- Published by National Institute of Standards and Technology (NIST)
Practical guide for collecting feedback from NIST SRM & RM users :
One way NIST ensures that measurements are accurate and compatible is by certifying and providing over 1 300 Standard Reference Materials® (SRM®) with well-characterized composition, properties, or both. Customers use these materials to calibrate instruments, verify specific measurements, and develop new measurement methods. However, sales data alone is insufficient to determine when to update or restock these materials. Collecting customer data systematically can help make informed decisions and reduce waste and missed opportunities. In 2023, NIST SRM 1950, Metabolites in Frozen Human Plasma, had a supply remaining for approximately 4 years. A decision was needed on whether to renew SRM 1950 and/or develop new reference materials in the coming years–a process that typically takes 5 to 7 years. The Information Technology Laboratory (ITL) Information Access Division (IAD) and the Material Measurement Laboratory (MML) Chemical Sciences Division (CSD) collaborated to conduct an online customer and stakeholder survey following established and rigorous methodology and process. The survey development process and the artifacts produced can serve as a model with templates for future measurement services projects to gather market research data and inform planning and development in a repeatable and consistent way. This document provides a practical, step-by-step guide to the survey development process for collecting feedback from NIST reference materials users and customers. It aims to provide concise guidance, complete with artifacts and templates, using the 2023 NIST SRM 1950 customer feedback survey project to illustrate how to conduct a user feedback survey following an 8-step survey development process. This practical guide outlines a process for developing surveys incorporating stakeholder feedback into decision-making for new measurement service projects, which can be reused or adapted.
- Open Access
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Bilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- 5 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (10) , 1892-1903
Open AccessBilirubin measurements in neonates: uniform neonatal treatment can only be achieved by improved standardization
Measurement of total bilirubin (TBil) concentration in serum is the gold standard approach for diagnosing neonatal unconjugated hyperbilirubinemia. It is of utmost importance that the measured TBil concentration is sufficiently accurate to prevent under treatment, unnecessary escalation of care, or overtreatment. However, it is widely recognized that TBil measurements urgently require improvement in neonatal clinical chemistry. External quality assessment (EQA) programs for TBil assess for differences between laboratories and provide supporting evidence of significant differences between various methods, manufacturers and measurement platforms. At the same time, many countries have adopted or only slightly adapted the neonatal hyperbilirubinemia management guidelines from the USA or UK, often without addressing differences in the methodology of TBil measurements. In this report, we provide an overview of the components of bilirubin that are measured by laboratory platforms, the availability of current reference measurement procedures and reference materials, and the role of EQA surveys in this context. Furthermore, the current status of agreement in neonatal bilirubin against clinical decision thresholds is reviewed. We advocate for enhancements in accuracy and comparability of neonatal TBil measurements, propose a path forward to accomplish this, and reflect on the position of the International Federation for Clinical Chemistry and Laboratory Medicine (IFCC) Working Group Neonatal Bilirubin (WG-NB) in this matter.
- 22 June 2023
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 3666 :
The National Institute of Standards and Technology (NIST) Standard Reference Material® (SRM®) 3666 Albumin and Creatinine in Frozen Human Urine (Level 1 to Level 4) delivers certified values for albumin and creatinine in human urine. The material is intended for 1) use in validating measurement procedures and 2) use in qualifying control materials produced in-house and analyzed using measurement methods for the determination of albumin, creatinine, or the albumin-to-creatinine ratio (ACR) in human urine. A unit of SRM 3666 consists of four (4) vials of frozen pooled human urine with endogenous levels of albumin determined using the NIST candidate reference measurement procedure (RMP) for albumin in urine [1]; and creatinine determined using the NIST RMP for creatinine in serum [2]. The certified values and associated uncertainties for albumin and creatinine were used to calculate the ACR for each level (Level 1 to Level 4). This publication documents the production, measurement processes, results, and statistical evaluations involved in the production and certification of SRM 3666.
- 22 June 2023
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 3666 :
The National Institute of Standards and Technology (NIST) Standard Reference Material® (SRM®) 3666 Albumin and Creatinine in Frozen Human Urine (Level 1 to Level 4) delivers certified values for albumin and creatinine in human urine. The material is intended for 1) use in validating measurement procedures and 2) use in qualifying control materials produced in-house and analyzed using measurement methods for the determination of albumin, creatinine, or the albumin-to-creatinine ratio (ACR) in human urine. A unit of SRM 3666 consists of four (4) vials of frozen pooled human urine with endogenous levels of albumin determined using the NIST candidate reference measurement procedure (RMP) for albumin in urine [1]; and creatinine determined using the NIST RMP for creatinine in serum [2]. The certified values and associated uncertainties for albumin and creatinine were used to calculate the ACR for each level (Level 1 to Level 4). This publication documents the production, measurement processes, results, and statistical evaluations involved in the production and certification of SRM 3666.
- 12 December 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (5) , 809-821
Development of an improved standard reference material for folate vitamers in human serum
The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC–MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates. Graphical Abstract
- 12 December 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (5) , 809-821
Development of an improved standard reference material for folate vitamers in human serum
The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC–MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates. Graphical Abstract