GWGuodong Wang

Guodong Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guodong Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Small-Rib-Height Perfobond Strip Connectors (SRHPBLs) in Steel–UHPC Composite Beams: Static Behavior Under Combined Tension–Shear Loads

    by Feiyang Ma, Ruyu Shen, Bingxiong Xian, Guodong Wang, Shu Fang, Haibo Jiang

    Steel–ultra-high-performance concrete (UHPC) composite beams with small-rib-height perfobond strip connectors (SRHPBLs) exhibited advantages of light weight and high bearing capacity, demonstrating the potential for applications of UHPC in bridge engineering. During service stages, the composite beams were usually under combined tension–shear loads, rather than pure shear loads. Nevertheless, there were research gaps in the static behavior of SRHPBLs embedded in UHPC under combined tension–shear loads, which limited their applications in practice. To address this issue, systematic experimental and theoretical analyses were conducted in the present study, considering the test variables of tension–shear ratio, row number, and strip number. It was demonstrated that the tension–shear ratio had less effect on ultimate shear strength, initial shear stiffness, and ultimate slip of SRHPBLs. When the tension–shear ratio was increased from 0 to 0.42, the shear capacity, initial shear stiffness, and slip at peak load of SRHPBLs decreased by 24.31%,19.02%, and 22.00%, respectively. However, increasing the row number and strip number significantly improved the shear performance of SRHPBLs. Compared to the single-row specimens, the shear capacity and initial shear stiffness of the three-row specimens increased by an average of 92.82% and 48.77%, respectively. The shear capacity and initial shear stiffness of the twin-strip specimens increased by an average of 103.84% and 87.80%, respectively, compared to the single-strip specimens. Finally, more accurate models were proposed to predict the shear–tension relationship and ultimate shear capacity of SRHPBLs embedded in UHPC under combined tension–shear loads.

  • Open Access

    Shear Performance of Prefabricated Steel Ultra-High-Performance Concrete (UHPC) Composite Beams under Combined Tensile and Shear Loads: Single Embedded Nut Bolts vs. Studs

    by Guodong Wang, Bingxiong Xian, Feiyang Ma, Shu Fang

    Ultra-high-performance concrete (UHPC) is widely used in precast concrete-steel composite beams because of its beneficial properties, including reduced structural weight, higher flexural rigidity, and reduced tensile crack formation. In comparison to conventional steel-concrete composite beams, steel-UHPC composite beams exhibit superior characteristics, including reduced structural deadweight, enhanced flexural stiffness, and the capacity to withstand tensile cracking. One successful attempt at meeting the current demands for expedited girder engineering is the development of steel-UHPC composite beams with full-depth precast slabs as key components affecting the overall structural performance using dismountable single embedded nut bolts (SENBs) and widely used studs as competitive alternatives. In contrast, shear connectors are exposed to a combined tensile and shear stress in service life rather than shear only. The corresponding scientific problem is the problem of combined effects under stress in practical applications, but there is currently no relevant research. The shear performance of SENBs in precast steel-UHPC composite beams under tension and shear loads remains unclear. For this purpose, ten push-out specimens and theoretical analyses were performed in this paper, considering the influence of the connector’s type and tensile-to-shear ratio. However, ten specimens were conducted to investigate the tensile-to-shear ratio, and the connector’s type on shear performance is limited. In the future, an increasing number of specimens and test parameters should be considered to investigate the shear performance of precast steel-UHPC composite beams. An increase in the tension-to-shear ratio resulted in a substantial reduction in the ultimate shear capacity, initial shear stiffness, and ductility of the studs. The increase in the tensile-shear ratio from 0 to 0.47 resulted in a 16.9% decline in the ultimate shear capacity, a 30.4% reduction in the initial shear stiffness, and a 21.7% decrease in the ductility of the Series I samples. However, an increase in the tensile-to-shear ratio of the Series II samples from 0 to 0.47 resulted in a 31.3% decline in ultimate shear strength, a 33.2% decline in initial shear stiffness, and a 41.9% decline in ductility. The SENBs demonstrated minimal deviations in ultimate shear capacity compared to their stud counterparts, despite exhibiting notable differences in shear stiffness, and ductility. A lower tensile-to-shear ratio was recommended in practical engineering, which might achieve a larger ultimate shear capacity, stiffness, and ductility. The design-oriented models with enhanced applicability were developed to predict the tension-shear relationship and the load-slip curve of SENBs in prefabricated steel-UHPC composite beams subjected to combined tensile and shear loads. For a tensile-shear relationship model, the point error range was 0 to 0.08, with an average error of 0.03. The square coefficient (R2) was 0.99 for a load-slip curve model. The study findings could offer a credible reference for the shear mechanism of such economical and environmentally friendly precast steel-UHPC composite beams in accelerated bridge construction.


  • Open Access

    Research on the Bonding Performance of BFRP Bars with Reactive Powder Concrete

    by Jie Xiao, Yikang Murong, Xiyuan Chen, Lingfei Liu, Keyi Zhai, Haibo Jiang, Linhai Huang, Guodong Wang

    In recent years, replacing steel bars with basalt fiber-reinforced polymer (BFRP) bars and replacing ordinary concrete with reactive powder concrete (RPC) are considered effective solutions to the corrosion problem of steel bars in ordinary reinforced concrete structures. In order to study the bonding performance between BFRP bars and RPC, a total of 27 bonding specimens were tested by pull-out test. The effects of steel fiber volume content (0%, 1.5%, 2%), protective layer thickness (25 mm, 40 mm, 55 mm, 69 mm), and bond anchorage length of bars (3 d, 4 d, 5 d; d is the diameter of the bars) on the bond performance were studied. The experimental results indicated that the BFRP bar and reactive powder (RPC) concrete interface exhibited better bonding performance, and the steel fibers mixed in RPC can play the role of crack-blocking enhancement in the specimen, which improves the shear and tensile properties of the concrete, thus improving the bond strength between BFRP bar and RPC. Three failure modes were observed in the pull-out tests: BFRP bar shear failure, splitting failure, and concrete shear failure. The bond strengths of BFRP bars and RPC with 0%, 1.5%, and 2% steel fiber content were 24.2 MPa, 32.1 MPa, and 34.5 MPa, respectively. With the increase in bond anchorage length, the ultimate bond strength tended to increase first and then decrease. There may be an optimal bonding length between BFRP bar and reactive powder concrete, and when the optimal bonding length is exceeded, the bond strength decreases with the increase in bonding length. With the increase in the protective layer thickness, the improvement in the bond strength of the BFRP bar and RPC was not very significant.