Blanca Quesada-Ocete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Blanca Quesada-Ocete has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Aurelio Quesada
Arrhythmia Unit, Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain
2 shared publications - Carl J. Lavie
Department of Cardiovascular Diseases, John Ochsner Heart and Vascular Institute, Ochsner Clinical School-The University of Queensland School of Medicine, New Orleans, Louisiana, USA
2 shared publications - Daniel P. Morin
Cardiac Electrophysiology Laboratory, University of California, San Francisco (D.P.M.).
2 shared publications - Fabian Sanchis-Gomar
Department of Medicine, Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USA
2 shared publications - Fernando de la Guía-Galipienso
Policlínica Glorieta, Dénia, Spain; REMA Clinic - Sports Cardiology, Dénia, Spain; HCB Benidorm Hospital, Alicante, Spain; Department of Pathology, Catholic University of Valencia - San Vicente Mártir, Valencia, Spain
2 shared publications - Javier Jiménez-Bello
Arrhythmia Unit, Cardiology Service, General University Hospital Consortium of Valencia, 46014 Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 6 June 2025
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 10 (4) , e1302
A closed-loop spinal cord stimulation system in a patient with an implantable cardioverter defibrillator
Introduction: Spinal cord stimulation (SCS) devices and implantable cardioverter defibrillators (ICDs) are well-established therapies for chronic pain management and mortality prevention in cardiovascular pathologies, respectively. As both devices rely on electrical current, there are concerns regarding potential interference between them that could lead to severe consequences. Methods: In this case report, we describe the case of a 50-year-old woman who had been implanted with an ICD for 5 years due to ischemic cardiopathy and class III heart failure symptoms, and who was referred to the Pain Unit after 4 years of persistent pain on the soles of her feet, which had not responded to opioids nor to percutaneous procedures. Thus, after being deemed suitable by anesthesiologists and obtaining psychological approval, she underwent implantation of an SCS closed-loop system. Results: Three months after the procedure, she reported an 80% relief of her pain. Both devices effectively functioned at all times, and no interference was observed. Conclusion: Pain management using a closed-loop SCS in a patient with an ICD can be safely performed without interference between the devices.
- 6 June 2025
- Published by Wolters Kluwer Health in Pain Reports
- Vol. 10 (4) , e1302
Open AccessA closed-loop spinal cord stimulation system in a patient with an implantable cardioverter defibrillator
Introduction: Spinal cord stimulation (SCS) devices and implantable cardioverter defibrillators (ICDs) are well-established therapies for chronic pain management and mortality prevention in cardiovascular pathologies, respectively. As both devices rely on electrical current, there are concerns regarding potential interference between them that could lead to severe consequences. Methods: In this case report, we describe the case of a 50-year-old woman who had been implanted with an ICD for 5 years due to ischemic cardiopathy and class III heart failure symptoms, and who was referred to the Pain Unit after 4 years of persistent pain on the soles of her feet, which had not responded to opioids nor to percutaneous procedures. Thus, after being deemed suitable by anesthesiologists and obtaining psychological approval, she underwent implantation of an SCS closed-loop system. Results: Three months after the procedure, she reported an 80% relief of her pain. Both devices effectively functioned at all times, and no interference was observed. Conclusion: Pain management using a closed-loop SCS in a patient with an ICD can be safely performed without interference between the devices.
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Long-term time-course of atrial sensing and incidence of atrial fibrillation in patients with VDD versus DDD pacemakers
Introduction: VDD pacemakers (PM) theoretically have the same advantages with respect to maintaining atrioventricular (AV) synchrony as dual-chamber (DDD) pacemakers, with lower costs and simpler implantation procedure. However, their use is often limited by concerns about the maintenance of atrial sensing (AS) and the occurrence of atrial fibrillation (AF). Purpose: We aimed to compare long-term atrial sensing stability, the incidence of AF and complications in VDD and DDD systems. Methods: We retrospectively enrolled patients who underwent VDD or DDD PM implantation for AV block between 2014 and 2021 from 2 centers. Clinical, analytical and electrical variables at implantation, their evolution and events at follow-up (25.2±16.2 months) were collected, comparing the groups by Kaplan-Meier and Cox multivariate analysis. Results: 487 patients who underwent PM implantation were included, 189 (38,8%) received a VDD PM and 298 (61,2%) a DDD PM. Patients with VDD were older and had a higher prevalence of risk factors and lower atrial voltage at implantation (Table). Complications at implantation and early complications were scarce and without significant differences in both groups. During follow-up, there was a reduction in atrial voltage in the VDD group (implant 1.4+0.8 mV; follow-up 1.2+0.9 mV; p<0.01), with stability in the DDD group (3.8+2.1 vs 3.9+2.2 mV). Total percentages of AS loss were 23.2% (VDD) vs 2.3% (DDD); p<0.01) (Figure 1). In the Cox multivariate analysis the risk of late AS loss was higher in the VDD group (HR=7.6; 95% CI 2.86-20.3; p<0.001) together with the AS values at implant (HR=0.72; 95% CI 0.52-1.00; p=0.052). AS loss was corrected with reprogramming in 23 patients, reintervention was needed in 1 (2%) and VVI was abandoned in 27 (53%). The risk of AF occurrence was lower in the VDD group (HR=0.39 CI 95% 0.18-0.87; p=0.021) (Figure 2). Conclusions: In the long term, AS is significantly reduced in VDD MPs, leading to its loss in a quarter of VDD patients. It is usually correctable with reprogramming, rarely requiring abandonment to VVI. AS at implantation is crucial as it is directed related to the AS during follow-up. DDD PMs were independently associated with a higher incidence of AF, with no differences in the remaining complications.TableFigure
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessLong-term time-course of atrial sensing and incidence of atrial fibrillation in patients with VDD versus DDD pacemakers
Introduction: VDD pacemakers (PM) theoretically have the same advantages with respect to maintaining atrioventricular (AV) synchrony as dual-chamber (DDD) pacemakers, with lower costs and simpler implantation procedure. However, their use is often limited by concerns about the maintenance of atrial sensing (AS) and the occurrence of atrial fibrillation (AF). Purpose: We aimed to compare long-term atrial sensing stability, the incidence of AF and complications in VDD and DDD systems. Methods: We retrospectively enrolled patients who underwent VDD or DDD PM implantation for AV block between 2014 and 2021 from 2 centers. Clinical, analytical and electrical variables at implantation, their evolution and events at follow-up (25.2±16.2 months) were collected, comparing the groups by Kaplan-Meier and Cox multivariate analysis. Results: 487 patients who underwent PM implantation were included, 189 (38,8%) received a VDD PM and 298 (61,2%) a DDD PM. Patients with VDD were older and had a higher prevalence of risk factors and lower atrial voltage at implantation (Table). Complications at implantation and early complications were scarce and without significant differences in both groups. During follow-up, there was a reduction in atrial voltage in the VDD group (implant 1.4+0.8 mV; follow-up 1.2+0.9 mV; p<0.01), with stability in the DDD group (3.8+2.1 vs 3.9+2.2 mV). Total percentages of AS loss were 23.2% (VDD) vs 2.3% (DDD); p<0.01) (Figure 1). In the Cox multivariate analysis the risk of late AS loss was higher in the VDD group (HR=7.6; 95% CI 2.86-20.3; p<0.001) together with the AS values at implant (HR=0.72; 95% CI 0.52-1.00; p=0.052). AS loss was corrected with reprogramming in 23 patients, reintervention was needed in 1 (2%) and VVI was abandoned in 27 (53%). The risk of AF occurrence was lower in the VDD group (HR=0.39 CI 95% 0.18-0.87; p=0.021) (Figure 2). Conclusions: In the long term, AS is significantly reduced in VDD MPs, leading to its loss in a quarter of VDD patients. It is usually correctable with reprogramming, rarely requiring abandonment to VVI. AS at implantation is crucial as it is directed related to the AS during follow-up. DDD PMs were independently associated with a higher incidence of AF, with no differences in the remaining complications.TableFigure
- Open Access
- 18 October 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (10) , 434
Gender-Based Clinical, Therapeutic Strategies and Prognosis Differences in Atrial Fibrillation
Background: There are limited data on gender-based differences in atrial fibrillation (AF) treatment and prognosis. We aimed to examine gender-related differences in medical attention in an emergency department (ED) and follow-up (FU) among patients diagnosed with an AF episode and to determine whether there are gender-related differences in clinical characteristics, therapeutic strategies, and long-term adverse events in this population. Methods: We performed a retrospective observational study of patients who presented to a tertiary hospital ER for AF from 2010 to 2015, with a minimum FU of one year. Data on medical attention received, mortality, and other adverse outcomes were collected and analyzed. Results: Among the 2013 patients selected, 1232 (60%) were female. Women were less likely than men to be evaluated by a cardiologist during the ED visit (11.5% vs. 16.6%, p = 0.001) and were less likely to be admitted (5.9% vs. 9.5%, p < 0.05). Electrical cardioversion was performed more frequently in men, both during the first episode (3.4% vs. 1.2%, p = 0.001) and during FU (15.9% vs. 10.6%, p < 0.001), despite a lower AF recurrence rate in women (9.9% vs. 18.1%). During FU, women had more hospitalizations for heart failure (26.2% vs. 16.1%, p < 0.001). Conclusions: In patients with AF, although there were no gender differences in mortality, there were significant differences in clinical outcomes, medical attention received, and therapeutic strategies. Women underwent fewer attempts at cardioversion, had a lower probability of being evaluated by cardiologists, and showed a higher probability of hospitalization for heart failure. Being alert to these inequities should facilitate the adoption of measures to correct them.
- 18 October 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (10) , 434
Open AccessGender-Based Clinical, Therapeutic Strategies and Prognosis Differences in Atrial Fibrillation
Background: There are limited data on gender-based differences in atrial fibrillation (AF) treatment and prognosis. We aimed to examine gender-related differences in medical attention in an emergency department (ED) and follow-up (FU) among patients diagnosed with an AF episode and to determine whether there are gender-related differences in clinical characteristics, therapeutic strategies, and long-term adverse events in this population. Methods: We performed a retrospective observational study of patients who presented to a tertiary hospital ER for AF from 2010 to 2015, with a minimum FU of one year. Data on medical attention received, mortality, and other adverse outcomes were collected and analyzed. Results: Among the 2013 patients selected, 1232 (60%) were female. Women were less likely than men to be evaluated by a cardiologist during the ED visit (11.5% vs. 16.6%, p = 0.001) and were less likely to be admitted (5.9% vs. 9.5%, p < 0.05). Electrical cardioversion was performed more frequently in men, both during the first episode (3.4% vs. 1.2%, p = 0.001) and during FU (15.9% vs. 10.6%, p < 0.001), despite a lower AF recurrence rate in women (9.9% vs. 18.1%). During FU, women had more hospitalizations for heart failure (26.2% vs. 16.1%, p < 0.001). Conclusions: In patients with AF, although there were no gender differences in mortality, there were significant differences in clinical outcomes, medical attention received, and therapeutic strategies. Women underwent fewer attempts at cardioversion, had a lower probability of being evaluated by cardiologists, and showed a higher probability of hospitalization for heart failure. Being alert to these inequities should facilitate the adoption of measures to correct them.
- Open Access
- 17 August 2023
- Published by MDPI AG in Preprints.org
Gender-Based Clinical, Therapeutic Strategies and Prognosis Differences in Atrial Fibrillation
Background: There is limited data on gender-based differences in atrial fibrillation (AF) treatment and prognosis. Our aim was to examine gender-related differences in medical attention in emergency department (ED) and follow-up (FU) among patients diagnosed with an AF episode and to determine whether there are gender-related differences in clinical characteristics, therapeutic strategies and long-term adverse events in this population. Methods: We performed a retrospective observational study of patients who presented to a tertiary hospital ER for AF from 2010-2015, with a minimum FU of one year. Data on medical attention received, mortality and other adverse outcomes were collected and analyzed. Results: Among the 2 013 patients selected, 1232 (60%) was female. Women were less likely than men to be evaluated by a cardiologist during the ED visit (11.5% vs. 16.6%, p=0.001) and were less likely to be admitted (5.9% vs. 9.5%, p<0.05). Electrical cardioversion was performed more frequently in men, both during the first episode (3.4% vs. 1.2%, p=0.001) and during FU (15.9% vs. 10.6%, p<0.001), in spite of a lower AF recurrence rate in women (9.9% vs 18.1%). During FU, women had more hospitalizations for heart failure (26.2% vs. 16.1%, p<0.001). Conclusions: In patients with AF, although no gender differences in mortality, there were significant differences in clinical outcomes, medical attention received, and therapeutic strategies. Women underwent fewer attempts at cardioversion, had a lower probability of being evaluated by cardiologists and showed a higher probability of hospitalization for heart failure. Being alert to these iniquities should facilitate to adopt measures to correct them.
- 17 August 2023
- Published by MDPI AG in Preprints.org
Open AccessGender-Based Clinical, Therapeutic Strategies and Prognosis Differences in Atrial Fibrillation
Background: There is limited data on gender-based differences in atrial fibrillation (AF) treatment and prognosis. Our aim was to examine gender-related differences in medical attention in emergency department (ED) and follow-up (FU) among patients diagnosed with an AF episode and to determine whether there are gender-related differences in clinical characteristics, therapeutic strategies and long-term adverse events in this population. Methods: We performed a retrospective observational study of patients who presented to a tertiary hospital ER for AF from 2010-2015, with a minimum FU of one year. Data on medical attention received, mortality and other adverse outcomes were collected and analyzed. Results: Among the 2 013 patients selected, 1232 (60%) was female. Women were less likely than men to be evaluated by a cardiologist during the ED visit (11.5% vs. 16.6%, p=0.001) and were less likely to be admitted (5.9% vs. 9.5%, p<0.05). Electrical cardioversion was performed more frequently in men, both during the first episode (3.4% vs. 1.2%, p=0.001) and during FU (15.9% vs. 10.6%, p<0.001), in spite of a lower AF recurrence rate in women (9.9% vs 18.1%). During FU, women had more hospitalizations for heart failure (26.2% vs. 16.1%, p<0.001). Conclusions: In patients with AF, although no gender differences in mortality, there were significant differences in clinical outcomes, medical attention received, and therapeutic strategies. Women underwent fewer attempts at cardioversion, had a lower probability of being evaluated by cardiologists and showed a higher probability of hospitalization for heart failure. Being alert to these iniquities should facilitate to adopt measures to correct them.