Job Mukwatamundu
Research Subjects
Research Interests
Job Mukwatamundu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Adithya Cattamanchi
Center for Tuberculosis, Institute for Global Health Sciences, University of California San Francisco , San Francisco, California
3 shared publications Alexey Ball
Global Health Labs, Inc
3 shared publications- Amy Steadman
Global Health Labs, Inc
3 shared publications Khushboo Khimani
Global Health Labs, Inc
3 shared publications- Lucy Asege
WALIMU
3 shared publications - Alfred Andama
Department of Internal Medicine, Makerere University College of Health Sciences, Kampala, Uganda
2 shared publications
Latest Publications
- Open Access
Diagnostic accuracy of swab-based molecular tests for tuberculosis using novel near point-of-care platforms: A multi-country evaluation
Background Swab-based molecular platforms that enable testing of both sputum (via swabs swirled in sputum) and tongue swabs are emerging as a promising option for more accessible and lower cost molecular testing for tuberculosis (TB). We conducted a multi-country evaluation of two novel swab-based molecular tests: Molbio Truenat MTB Ultima (MTB Ultima) and Pluslife MiniDock MTB Test (MiniDock MTB). Methods Consecutive people ≥12 years old with presumptive TB were enrolled at outpatient health centers in India, Uganda, and Vietnam. We collected two tongue swabs and prepared two sputum swabs for MTB Ultima and MiniDock MTB testing, then evaluated the diagnostic accuracy of MTB Ultima and MiniDock MTB using both swab types against a sputum liquid culture-based microbiological reference standard (MRS). The diagnostic accuracy of swab-based molecular tests was also compared to sputum Xpert MTB/RIF Ultra (Xpert Ultra) and auramine smear microscopy. Findings From January to September 2024, 1,050 participants were included in the tongue swab MTB Ultima evaluation, 197 in the sputum swab MTB Ultima evaluation, and 322 in the MiniDock MTB evaluations. In comparison to sputum Xpert Ultra, sensitivity was similar for both sputum swab MTB Ultima (93.6% vs. 100.0%, difference -6.4%, [95% CI: -15.5, 2.7], p=0.25) and MiniDock MTB (91.0% vs. 94.0%, difference –3.0% [95% CI: -8.6, 2.6], p=0.50). In comparison to sputum smear microscopy, sensitivity was higher for both tongue swab MTB Ultima (77.9% vs. 59.1%, difference 18.8% [95% CI: 10.8, 26.8], p98%) for both tests with sputum swabs and tongue swabs. Interpretation MTB Ultima and MiniDock MTB have similar accuracy to current sputum-based molecular tests with sputum swabs and meet minimum accuracy thresholds for a non-sputum, near point-of-care molecular test with tongue swabs. These tests offer strong potential to make universal molecular testing for TB a reality.
Open AccessDiagnostic accuracy of swab-based molecular tests for tuberculosis using novel near point-of-care platforms: A multi-country evaluation
Background Swab-based molecular platforms that enable testing of both sputum (via swabs swirled in sputum) and tongue swabs are emerging as a promising option for more accessible and lower cost molecular testing for tuberculosis (TB). We conducted a multi-country evaluation of two novel swab-based molecular tests: Molbio Truenat MTB Ultima (MTB Ultima) and Pluslife MiniDock MTB Test (MiniDock MTB). Methods Consecutive people ≥12 years old with presumptive TB were enrolled at outpatient health centers in India, Uganda, and Vietnam. We collected two tongue swabs and prepared two sputum swabs for MTB Ultima and MiniDock MTB testing, then evaluated the diagnostic accuracy of MTB Ultima and MiniDock MTB using both swab types against a sputum liquid culture-based microbiological reference standard (MRS). The diagnostic accuracy of swab-based molecular tests was also compared to sputum Xpert MTB/RIF Ultra (Xpert Ultra) and auramine smear microscopy. Findings From January to September 2024, 1,050 participants were included in the tongue swab MTB Ultima evaluation, 197 in the sputum swab MTB Ultima evaluation, and 322 in the MiniDock MTB evaluations. In comparison to sputum Xpert Ultra, sensitivity was similar for both sputum swab MTB Ultima (93.6% vs. 100.0%, difference -6.4%, [95% CI: -15.5, 2.7], p=0.25) and MiniDock MTB (91.0% vs. 94.0%, difference –3.0% [95% CI: -8.6, 2.6], p=0.50). In comparison to sputum smear microscopy, sensitivity was higher for both tongue swab MTB Ultima (77.9% vs. 59.1%, difference 18.8% [95% CI: 10.8, 26.8], p98%) for both tests with sputum swabs and tongue swabs. Interpretation MTB Ultima and MiniDock MTB have similar accuracy to current sputum-based molecular tests with sputum swabs and meet minimum accuracy thresholds for a non-sputum, near point-of-care molecular test with tongue swabs. These tests offer strong potential to make universal molecular testing for TB a reality.
- Top Cited PapersOpen Access
- 2 February 2024
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 78 (5) , 1313-1320
New Manual Quantitative Polymerase Chain Reaction Assay Validated on Tongue Swabs Collected and Processed in Uganda Shows Sensitivity That Rivals Sputum-based Molecular Tuberculosis Diagnostics
Background: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2–99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. Conclusions: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab–based TB diagnostics.
- 2 February 2024
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 78 (5) , 1313-1320
Top Cited PapersOpen AccessNew Manual Quantitative Polymerase Chain Reaction Assay Validated on Tongue Swabs Collected and Processed in Uganda Shows Sensitivity That Rivals Sputum-based Molecular Tuberculosis Diagnostics
Background: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2–99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. Conclusions: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab–based TB diagnostics.
- Open Access
New manual qPCR assay validated on tongue swabs collected and processed in Uganda shows sensitivity that rivals sputum-based molecular TB diagnostics
Background: Reliance on sputum-based testing is a key barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce and sputum processing increases the complexity and cost of molecular assays. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at two health centers in Kampala, Uganda. We collected routine demographic and clinical information, sputum for routine TB testing (one Xpert MTB/RIF Ultra® and two liquid cultures), and up to four tongue swabs for same-day qPCR. We evaluated tongue swab qPCR diagnostic accuracy in reference to sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared two swab types (Copan FLOQSWAB® and Steripack® spun polyester swabs). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were living with HIV (PLHIV) and 32.3% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% [96.2-99.1] of participants. Tongue swab qPCR sensitivity was 91.0% [84.6-94.9] and specificity 98.9% [96.2-99.8] vs. microbiological reference standard (MRS). A single tongue swab recovered a seven-log range of TB copies, with a decreasing recovery trend among four serial swabs. We found no difference between swab types. Conclusions: Tongue swabs show promise as an alternative to sputum for TB diagnosis, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.
Open AccessNew manual qPCR assay validated on tongue swabs collected and processed in Uganda shows sensitivity that rivals sputum-based molecular TB diagnostics
Background: Reliance on sputum-based testing is a key barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce and sputum processing increases the complexity and cost of molecular assays. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at two health centers in Kampala, Uganda. We collected routine demographic and clinical information, sputum for routine TB testing (one Xpert MTB/RIF Ultra® and two liquid cultures), and up to four tongue swabs for same-day qPCR. We evaluated tongue swab qPCR diagnostic accuracy in reference to sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared two swab types (Copan FLOQSWAB® and Steripack® spun polyester swabs). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were living with HIV (PLHIV) and 32.3% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% [96.2-99.1] of participants. Tongue swab qPCR sensitivity was 91.0% [84.6-94.9] and specificity 98.9% [96.2-99.8] vs. microbiological reference standard (MRS). A single tongue swab recovered a seven-log range of TB copies, with a decreasing recovery trend among four serial swabs. We found no difference between swab types. Conclusions: Tongue swabs show promise as an alternative to sputum for TB diagnosis, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.