Sheng-Hsuan Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sheng-Hsuan Lin has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Aniket D. Borwankar
2 shared publications- Bora Gencturk
Univ. of Southern California
2 shared publications - Gregory Lucier
North Carolina State Univ
2 shared publications - Kyung Hoon Lee
Sonny Astani Department of Civil and Environmental Engineering, University of Southern California , Los Angeles, California 90089
2 shared publications Maikol Del Carpio
2 shared publicationsSusana Anacleto-Lupianez
2 shared publications
Latest Publications
- 17 November 2026
- Published by Elsevier in Engineering Structures
- Vol. 372
Seismic retrofit of shear-critical short captive columns using FRP jacketing
- 17 November 2026
- Published by Elsevier in Engineering Structures
- Vol. 372
Seismic retrofit of shear-critical short captive columns using FRP jacketing
- 1 October 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 30 (5)
Effect of Out-of-Plane Bending on Steel-Reinforced Masonry Wallettes Strengthened with Fiber-Reinforced Polymer
A significant portion of today’s masonry building stock consists of steel-reinforced concrete masonry unit (CMU) walls, including residential construction in coastal areas subject to extreme hydrometeorological events, as well as earth-retaining walls, resulting in out-of-plane bending. The addition of vertical internal steel reinforcement increases the bending capacity and ductility of CMU walls. However, current design guides for strengthening of masonry walls focus mainly on unreinforced masonry. This paper presents the results of steel-reinforced CMU wallettes strengthened with externally bonded (EB) fiber-reinforced polymer (FRP) systems under out-of-plane bending. Nine steel-reinforced wallettes were constructed using lightweight two-cell CMUs and tested in three-point out-of-plane bending under monotonic loading. One of which served as an unstrengthened control, while the other eight were strengthened on one face with wet lay-up carbon or glass EB-FRP systems. Two failure modes were observed: FRP debonding and FRP rupture. The experimental results show that the flexural load-carrying capacity and postcracking stiffness of all the strengthened wallettes were increased, and the increment is related to the FRP reinforcement ratio. In addition, this paper compares the experimentally measured maximum FRP strain with predictions from existing models. The research provides evidence that the current American Concrete Institute design guide for FRP-strengthened unreinforced CMU walls provides a conservative prediction using the debonding strain limit for the out-of-plane bending capacity generated by layered-sectional analysis of FRP-strengthened steel-reinforced CMU wallettes.
- 1 October 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 30 (5)
Effect of Out-of-Plane Bending on Steel-Reinforced Masonry Wallettes Strengthened with Fiber-Reinforced Polymer
A significant portion of today’s masonry building stock consists of steel-reinforced concrete masonry unit (CMU) walls, including residential construction in coastal areas subject to extreme hydrometeorological events, as well as earth-retaining walls, resulting in out-of-plane bending. The addition of vertical internal steel reinforcement increases the bending capacity and ductility of CMU walls. However, current design guides for strengthening of masonry walls focus mainly on unreinforced masonry. This paper presents the results of steel-reinforced CMU wallettes strengthened with externally bonded (EB) fiber-reinforced polymer (FRP) systems under out-of-plane bending. Nine steel-reinforced wallettes were constructed using lightweight two-cell CMUs and tested in three-point out-of-plane bending under monotonic loading. One of which served as an unstrengthened control, while the other eight were strengthened on one face with wet lay-up carbon or glass EB-FRP systems. Two failure modes were observed: FRP debonding and FRP rupture. The experimental results show that the flexural load-carrying capacity and postcracking stiffness of all the strengthened wallettes were increased, and the increment is related to the FRP reinforcement ratio. In addition, this paper compares the experimentally measured maximum FRP strain with predictions from existing models. The research provides evidence that the current American Concrete Institute design guide for FRP-strengthened unreinforced CMU walls provides a conservative prediction using the debonding strain limit for the out-of-plane bending capacity generated by layered-sectional analysis of FRP-strengthened steel-reinforced CMU wallettes.
- Open Access
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Seismic Retrofit of Shear-critical Short Captive Columns Using FRP Jacketing
This study investigates the seismic retrofit performance of shear-critical short captive reinforced concrete (RC) columns strengthened with fiber-reinforced polymer (FRP). Two design issues are addressed. The first is the cross-sectional shear-strength limit prescribed in ACI CODE-318-25, which can restrict the use of FRP retrofitting for short captive columns when the amplified shear demand exceeds the code-defined limit. The second is the effective FRP strain recommended in ACI PRC-440.2-23, which may overestimate the strain that is allowed in FRP for severely shear-critical short columns. Ten short captive RC columns with shear span-to-depth ratios of 1.02 and 1.16 were tested under reversed cyclic loading. The control specimens exhibited brittle shear failure, whereas the FRP-retrofitted specimens showed substantial improvements in shear strength, drift capacity, and energy dissipation. All retrofitted specimens achieved shear strengths exceeding the ACI CODE-318-25 cross-sectional limit, with measured strengths being 21% to 88% higher. However, these values remained below the ACI PRC-440.2-23 nominal predictions, primarily because the measured FRP strains at peak strength were below 0.2%, which is substantially lower than the 0.4% effective strain commonly used in design. These results indicate that the ACI 318 cross-sectional shear-strength limit may be overly restrictive for FRP-strengthened short captive columns, while the ACI 440 effective strain may overestimate the actual FRP contribution for short captive columns similar to those in this study. The findings support the practical use of FRP as a potential alternative to section enlargement for short captive columns, while also highlighting the need for special design considerations. These conclusions are based on the configurations tested in this study, and further research is needed to generalize the findings to other column geometries, shear-span-to-depth ratios, and FRP strengthening schemes.
- 3 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSeismic Retrofit of Shear-critical Short Captive Columns Using FRP Jacketing
This study investigates the seismic retrofit performance of shear-critical short captive reinforced concrete (RC) columns strengthened with fiber-reinforced polymer (FRP). Two design issues are addressed. The first is the cross-sectional shear-strength limit prescribed in ACI CODE-318-25, which can restrict the use of FRP retrofitting for short captive columns when the amplified shear demand exceeds the code-defined limit. The second is the effective FRP strain recommended in ACI PRC-440.2-23, which may overestimate the strain that is allowed in FRP for severely shear-critical short columns. Ten short captive RC columns with shear span-to-depth ratios of 1.02 and 1.16 were tested under reversed cyclic loading. The control specimens exhibited brittle shear failure, whereas the FRP-retrofitted specimens showed substantial improvements in shear strength, drift capacity, and energy dissipation. All retrofitted specimens achieved shear strengths exceeding the ACI CODE-318-25 cross-sectional limit, with measured strengths being 21% to 88% higher. However, these values remained below the ACI PRC-440.2-23 nominal predictions, primarily because the measured FRP strains at peak strength were below 0.2%, which is substantially lower than the 0.4% effective strain commonly used in design. These results indicate that the ACI 318 cross-sectional shear-strength limit may be overly restrictive for FRP-strengthened short captive columns, while the ACI 440 effective strain may overestimate the actual FRP contribution for short captive columns similar to those in this study. The findings support the practical use of FRP as a potential alternative to section enlargement for short captive columns, while also highlighting the need for special design considerations. These conclusions are based on the configurations tested in this study, and further research is needed to generalize the findings to other column geometries, shear-span-to-depth ratios, and FRP strengthening schemes.
- 10 August 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678 (4) , 804-818
Rapid Prestressed Concrete Retrofit with Prestressed Mechanically-Fastened Fiber-Reinforced Polymer: Field Performance and Observation for a Deteriorated Prestressed Concrete Bridge
This paper presents repairs to rural bridges in North Carolina that deteriorated as a result variously of aging, overweight traffic, and exposure to salts and sulfates. The prestressed concrete C-channel superstructures exhibited prestressing strand loss and displayed significant concrete spalling, with one structure having to be closed to traffic after a routine inspection. Analysis conducted using the American Association of State Highway and Transportations Officials (AASHTO) bridge load rating criteria concluded that repair techniques which strengthen deteriorated flexural elements without also restoring lost prestressing forces are insufficient to maintain load ratings in C-channel structures with heavily damaged prestressing tendons. A prestressed mechanically-fastened fiber-reinforced polymer (MF-FRP) retrofit solution was developed and successfully installed on three structures by the authors and North Carolina Department of Transportation maintenance crews. The most extensive of these three repairs is presented here in detail. The field applications and associated analysis show the temporary MF-FRP repair system is capable of restoring lost prestressing forces, allowing original inventory and operating ratings to remain in place until a permanent superstructure replacement can be scheduled. The most heavily repaired bridge remains in service after 23 months, its performance demonstrated by long-term monitoring data. As currently implemented, the MF-FRP repair is a viable temporary solution for maintaining traffic on a degraded structure while a replacement structure is designed, programmed, and implemented. Efforts to expand the MF-FRP repair into a longer-term solution are underway.
- 10 August 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678 (4) , 804-818
Rapid Prestressed Concrete Retrofit with Prestressed Mechanically-Fastened Fiber-Reinforced Polymer: Field Performance and Observation for a Deteriorated Prestressed Concrete Bridge
This paper presents repairs to rural bridges in North Carolina that deteriorated as a result variously of aging, overweight traffic, and exposure to salts and sulfates. The prestressed concrete C-channel superstructures exhibited prestressing strand loss and displayed significant concrete spalling, with one structure having to be closed to traffic after a routine inspection. Analysis conducted using the American Association of State Highway and Transportations Officials (AASHTO) bridge load rating criteria concluded that repair techniques which strengthen deteriorated flexural elements without also restoring lost prestressing forces are insufficient to maintain load ratings in C-channel structures with heavily damaged prestressing tendons. A prestressed mechanically-fastened fiber-reinforced polymer (MF-FRP) retrofit solution was developed and successfully installed on three structures by the authors and North Carolina Department of Transportation maintenance crews. The most extensive of these three repairs is presented here in detail. The field applications and associated analysis show the temporary MF-FRP repair system is capable of restoring lost prestressing forces, allowing original inventory and operating ratings to remain in place until a permanent superstructure replacement can be scheduled. The most heavily repaired bridge remains in service after 23 months, its performance demonstrated by long-term monitoring data. As currently implemented, the MF-FRP repair is a viable temporary solution for maintaining traffic on a degraded structure while a replacement structure is designed, programmed, and implemented. Efforts to expand the MF-FRP repair into a longer-term solution are underway.