Zhuang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhuang Liu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Huaili Jiang
Otolaryngology Head and Neck Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
3 shared publicationsKai Liu
Department of Radiology, Zhongshan Hospital, Fudan University, and Shanghai Institute of Medical Imaging, Shanghai, China
3 shared publicationsMenglong Zhao
Department of Radiology, Zhongshan Hospital, Fudan University, and Shanghai Institute of Medical Imaging, Shanghai, China
3 shared publications- Mengsu Zeng
Department of Radiology, Zhongshan Hospital, Fudan University, and Shanghai Institute of Medical Imaging, Shanghai, China
3 shared publications Shujie Zhang
Department of Radiology, Zhongshan Hospital, Fudan University, and Shanghai Institute of Medical Imaging, Shanghai, China
3 shared publicationsXixi Wen
United Imaging Healthcare, Shanghai, CHINA
3 shared publications
Latest Publications
- 8 October 2026
- Published by Springer Nature in European Radiology
- p. 1-10
Enabling unenhanced endolymphatic hydrops MRI: a subtraction method using 3D-FLAIR sequences with different inversion time
Objectives To evaluate an unenhanced three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between the perilymph and endolymph in a volunteer study, and unenhanced endolymphatic hydrops (EH) evaluation using subtraction images of the 3D-FLAIR with two inversion times (TI) in a patient study. Materials and methods In the volunteer study, unenhanced 3D-FLAIR using different TI were acquired from 10 healthy volunteers. Signal intensities (SIs) of the endolymph and perilymph were measured. In the patient study, the unenhanced 3D-FLAIR using two TI were acquired for subtraction of 202 patients, and compared with the enhanced 3D-FLAIR and three-dimensional inversion-recovery with real reconstruction (3D-real IR) sequences. Results In the volunteer study, the endolymphatic and perilymphatic signals exhibited distinct trends on 3D-FLAIR images as TI increased. There were apparent differences in SIs between them at some TI. In the patient study, unenhanced subtraction images similar to enhanced 3D-real IR were acquired. They had a lower image quality score (p < 0.001) but a higher signal-to-noise ratio (p < 0.001) than enhanced sequences. Contrast-to-noise ratio of them was lower than that of 3D-FLAIR (p < 0.001), but higher than that of 3D-real IR (p < 0.001). Using any two of the three images, excellent agreement could be found in EH grading. Conclusion The endolymph and perilymph could be distinguished by this unenhanced 3D-FLAIR. Subtraction-based unenhanced MR imaging for EH evaluation provided high image quality and showed excellent agreement with the contrast-enhanced sequences. Key Points Question Using previous single 3D-FLAIR sequence with long TR and CFA for unenhanced endolymphatic hydrops (EH) imaging, some patients were overrated due to the insufficient contrast. Findings Unenhanced subtraction images were applied to EH imaging with satisfactory quality. Between using them and two enhanced sequences, excellent agreement was found in EH evaluation. Clinical relevance Subtraction using the long TR and CFA three-dimensional fluid-attenuated inversion recovery sequences with two different inversion time holds significant value for unenhanced EH MRI. Graphical Abstract
- 8 October 2026
- Published by Springer Nature in European Radiology
- p. 1-10
Enabling unenhanced endolymphatic hydrops MRI: a subtraction method using 3D-FLAIR sequences with different inversion time
Objectives To evaluate an unenhanced three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between the perilymph and endolymph in a volunteer study, and unenhanced endolymphatic hydrops (EH) evaluation using subtraction images of the 3D-FLAIR with two inversion times (TI) in a patient study. Materials and methods In the volunteer study, unenhanced 3D-FLAIR using different TI were acquired from 10 healthy volunteers. Signal intensities (SIs) of the endolymph and perilymph were measured. In the patient study, the unenhanced 3D-FLAIR using two TI were acquired for subtraction of 202 patients, and compared with the enhanced 3D-FLAIR and three-dimensional inversion-recovery with real reconstruction (3D-real IR) sequences. Results In the volunteer study, the endolymphatic and perilymphatic signals exhibited distinct trends on 3D-FLAIR images as TI increased. There were apparent differences in SIs between them at some TI. In the patient study, unenhanced subtraction images similar to enhanced 3D-real IR were acquired. They had a lower image quality score (p < 0.001) but a higher signal-to-noise ratio (p < 0.001) than enhanced sequences. Contrast-to-noise ratio of them was lower than that of 3D-FLAIR (p < 0.001), but higher than that of 3D-real IR (p < 0.001). Using any two of the three images, excellent agreement could be found in EH grading. Conclusion The endolymph and perilymph could be distinguished by this unenhanced 3D-FLAIR. Subtraction-based unenhanced MR imaging for EH evaluation provided high image quality and showed excellent agreement with the contrast-enhanced sequences. Key Points Question Using previous single 3D-FLAIR sequence with long TR and CFA for unenhanced endolymphatic hydrops (EH) imaging, some patients were overrated due to the insufficient contrast. Findings Unenhanced subtraction images were applied to EH imaging with satisfactory quality. Between using them and two enhanced sequences, excellent agreement was found in EH evaluation. Clinical relevance Subtraction using the long TR and CFA three-dimensional fluid-attenuated inversion recovery sequences with two different inversion time holds significant value for unenhanced EH MRI. Graphical Abstract
- Open Access
- 8 December 2025
- Published by Springer Nature in BMC Medical Imaging
- Vol. 25 (1) , 502
Artifact reduction and diagnostic value of monoenergetic reconstructions from split-filter and dual-layer spectral detector dual-energy CT in early gastric cancer with titanium clip localization
Metal clip artifacts impair CT evaluation of early-stage gastric cancer (EGC). While various metal artifact reduction techniques exist, their application i
- 8 December 2025
- Published by Springer Nature in BMC Medical Imaging
- Vol. 25 (1) , 502
Open AccessArtifact reduction and diagnostic value of monoenergetic reconstructions from split-filter and dual-layer spectral detector dual-energy CT in early gastric cancer with titanium clip localization
Metal clip artifacts impair CT evaluation of early-stage gastric cancer (EGC). While various metal artifact reduction techniques exist, their application i
- 7 April 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (10) , 6610-6611
Reply to the Letter to the Editor: “An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops”
- 7 April 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (10) , 6610-6611
Reply to the Letter to the Editor: “An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops”
- 10 July 2024
- Published by Springer Nature in European Radiology
- Vol. 35 (1) , 29-37
An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops
Objectives To evaluate a three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between perilymph and endolymph in a phantom study, and unenhanced endolymphatic hydrops (EH) imaging in a patient study. Methods Three solutions in similar ion and protein concentrations with endolymph, perilymph, and cerebrospinal fluid were prepared for variable flip angle (VFA) 3D-FLAIR (TR 10,000 ms) and CFA (120°) 3D-FLAIR using different TR (10,000, 16,000, and 20,000 ms). Fifty-two patients with probable or definite Meniere’s disease received unenhanced CFA (120°) 3D-FLAIR using a long TR (20,000 ms) and 4-h-delay enhanced CFA (120°) 3D-FLAIR (TR 16,000 ms). Image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of them were compared. Agreement in the evaluation of the EH degree between them was analyzed. Results In the phantom study, CNRs between perilymphatic and endolymphatic samples of VFA 3D-FLAIR (TR 10,000 ms) and CFA 3D-FLAIR (TR 10,000, 16,000, and 20,000 ms) were 6.66 ± 1.30, 17.90 ± 2.76, 23.87 ± 3.09, and 28.22 ± 3.15 (p < 0.001). In patient study, average score (3.65 ± 0.48 vs. 4.19 ± 0.40), SNR (34.56 ± 9.80 vs. 51.40 ± 11.27), and CNR (30.66 ± 10.55 vs. 45.08 ± 12.27) of unenhanced 3D-FLAIR were lower than enhanced 3D-FLAIR (p < 0.001). Evaluations of the two sequences showed excellent agreement in the cochlear and vestibule (Kappa value: 0.898 and 0.909). Conclusions The CFA 3D-FLAIR sequence using a long TR could be used in unenhanced EH imaging with high accuracy. Clinical relevance statement Unenhanced imaging of endolymphatic hydrops is valuable in the diagnosis and follow-up of patients, especially those who cannot receive contrast-enhanced MRI. Key Points Ion and protein concentration differences can be utilized in differentiating endolymph and perilymph on MRI. Endolymphatic and perilymphatic samples could be differentiated in vitro on this 3D-FLAIR sequence. This unenhanced 3D-FLAIR sequence is in excellent agreement with the enhanced constant flip angle 3D-FLAIR sequence.
- 10 July 2024
- Published by Springer Nature in European Radiology
- Vol. 35 (1) , 29-37
An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops
Objectives To evaluate a three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between perilymph and endolymph in a phantom study, and unenhanced endolymphatic hydrops (EH) imaging in a patient study. Methods Three solutions in similar ion and protein concentrations with endolymph, perilymph, and cerebrospinal fluid were prepared for variable flip angle (VFA) 3D-FLAIR (TR 10,000 ms) and CFA (120°) 3D-FLAIR using different TR (10,000, 16,000, and 20,000 ms). Fifty-two patients with probable or definite Meniere’s disease received unenhanced CFA (120°) 3D-FLAIR using a long TR (20,000 ms) and 4-h-delay enhanced CFA (120°) 3D-FLAIR (TR 16,000 ms). Image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of them were compared. Agreement in the evaluation of the EH degree between them was analyzed. Results In the phantom study, CNRs between perilymphatic and endolymphatic samples of VFA 3D-FLAIR (TR 10,000 ms) and CFA 3D-FLAIR (TR 10,000, 16,000, and 20,000 ms) were 6.66 ± 1.30, 17.90 ± 2.76, 23.87 ± 3.09, and 28.22 ± 3.15 (p < 0.001). In patient study, average score (3.65 ± 0.48 vs. 4.19 ± 0.40), SNR (34.56 ± 9.80 vs. 51.40 ± 11.27), and CNR (30.66 ± 10.55 vs. 45.08 ± 12.27) of unenhanced 3D-FLAIR were lower than enhanced 3D-FLAIR (p < 0.001). Evaluations of the two sequences showed excellent agreement in the cochlear and vestibule (Kappa value: 0.898 and 0.909). Conclusions The CFA 3D-FLAIR sequence using a long TR could be used in unenhanced EH imaging with high accuracy. Clinical relevance statement Unenhanced imaging of endolymphatic hydrops is valuable in the diagnosis and follow-up of patients, especially those who cannot receive contrast-enhanced MRI. Key Points Ion and protein concentration differences can be utilized in differentiating endolymph and perilymph on MRI. Endolymphatic and perilymphatic samples could be differentiated in vitro on this 3D-FLAIR sequence. This unenhanced 3D-FLAIR sequence is in excellent agreement with the enhanced constant flip angle 3D-FLAIR sequence.
- 8 August 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (35) , 8464-8470
A general method for endowing hydrophobic nanoparticles with water dispersion abilities
Inorganic nanoparticles with long-chain ligands are usually hydrophobic. However, simple and practical methods for converting hydrophobic nanoparticles to hydrophilic nanoparticles are still lacking. Herein, we developed a general method involving using dimercaptosuccinic acid (DMSA) for endowing hydrophobic nanoparticles with water dispersion abilities. By mixing a tetrahydrofuran solution of DMSA with a cyclohexane solution of hydrophobic nanoparticles, the long-chain ligands were replaced with DMSA, with the replacement due to the strong and broad-spectrum coordination abilities of sulphydryls and carboxyls. Four representative kinds of hydrophobic nanoparticles, namely Ag, NaGdF4, TiO2, and ZnS nanoparticles, were selected for verifying the performance of this DMSA-based modification method. Meanwhile, this method can also widen the applications of hydrophobic nanoparticles and facilitate their being subjected to further graft modifications. We hope that our research will increase the chances for applications of nanomaterials to be made.
- 8 August 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (35) , 8464-8470
A general method for endowing hydrophobic nanoparticles with water dispersion abilities
Inorganic nanoparticles with long-chain ligands are usually hydrophobic. However, simple and practical methods for converting hydrophobic nanoparticles to hydrophilic nanoparticles are still lacking. Herein, we developed a general method involving using dimercaptosuccinic acid (DMSA) for endowing hydrophobic nanoparticles with water dispersion abilities. By mixing a tetrahydrofuran solution of DMSA with a cyclohexane solution of hydrophobic nanoparticles, the long-chain ligands were replaced with DMSA, with the replacement due to the strong and broad-spectrum coordination abilities of sulphydryls and carboxyls. Four representative kinds of hydrophobic nanoparticles, namely Ag, NaGdF4, TiO2, and ZnS nanoparticles, were selected for verifying the performance of this DMSA-based modification method. Meanwhile, this method can also widen the applications of hydrophobic nanoparticles and facilitate their being subjected to further graft modifications. We hope that our research will increase the chances for applications of nanomaterials to be made.