Mehedi Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mehedi Hasan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Armin Sedighi
Wayne State University
2 shared publications Md. Ariful Islam
Department of Robotics and Mechatronics Engineering, University of Dhaka, Dhaka, Bangladesh
1 shared publication- Niloy Irtisam
Department of Robotics and Mechatronics Engineering, University of Dhaka, Dhaka, Bangladesh
1 shared publication - Saadman Sakib
Department of Robotics and Mechatronics Engineering, University of Dhaka, Dhaka, Bangladesh
1 shared publication Sayed Saminur Rahman
Aromo Health, Chattogram, Bangladesh
1 shared publication- Shamim Ahmed Deowan
Department of Robotics and Mechatronics Engineering, University of Dhaka, Dhaka, Bangladesh
1 shared publication
Latest Publications
- Open Access
- 6 November 2026
- Published by Springer Nature in Research Square
A 3D-Printed Neural Probe with Geometry-Defined Lithography-Free Metallization and Parylene Encapsulation
Two-photon polymerization enables neural probes with complex three-dimensional geometries, but selectively metallizing and insulating these structures remains challenging. We present a geometry-defined fabrication process that combines trench-guided metallization with vapor-deposited Parylene-C encapsulation and lithography-free electrode exposure. Re-entrant trenches guide line-of-sight Ti/Au evaporation to form electrically separated interconnects connected to electrode sites and contact pads. A conformal Parylene-C coating then seals the high-aspect-ratio trenches over the interconnects, and a timed, maskless O₂ plasma etch-back followed by SF₆/O₂ plasma treatment exposes the electrodes and pads while retaining insulation over the recessed interconnects. We fabricated a prototype comprising a 2 mm-long shank with four mushroom-shaped electrodes, each 15 µm in diameter. Scanning electron microscopy showed metal deposition at the trench bottoms, Parylene-C coverage, and selective electrode exposure after plasma processing. Electrochemical impedance spectroscopy in phosphate-buffered saline showed an impedance magnitude of approximately 1 MΩ at 1 kHz before and after insertion into 0.6% agarose gel. The probe reached a 2 mm insertion depth without observed buckling or fracture. These results demonstrate a fabrication proof of concept for 3D-printed neural probes using geometry-defined metallization and selective Parylene encapsulation, providing a potential route toward scalable fabrication of 3D-printed bioelectronic microsystems
- 6 November 2026
- Published by Springer Nature in Research Square
Open AccessA 3D-Printed Neural Probe with Geometry-Defined Lithography-Free Metallization and Parylene Encapsulation
Two-photon polymerization enables neural probes with complex three-dimensional geometries, but selectively metallizing and insulating these structures remains challenging. We present a geometry-defined fabrication process that combines trench-guided metallization with vapor-deposited Parylene-C encapsulation and lithography-free electrode exposure. Re-entrant trenches guide line-of-sight Ti/Au evaporation to form electrically separated interconnects connected to electrode sites and contact pads. A conformal Parylene-C coating then seals the high-aspect-ratio trenches over the interconnects, and a timed, maskless O₂ plasma etch-back followed by SF₆/O₂ plasma treatment exposes the electrodes and pads while retaining insulation over the recessed interconnects. We fabricated a prototype comprising a 2 mm-long shank with four mushroom-shaped electrodes, each 15 µm in diameter. Scanning electron microscopy showed metal deposition at the trench bottoms, Parylene-C coverage, and selective electrode exposure after plasma processing. Electrochemical impedance spectroscopy in phosphate-buffered saline showed an impedance magnitude of approximately 1 MΩ at 1 kHz before and after insertion into 0.6% agarose gel. The probe reached a 2 mm insertion depth without observed buckling or fracture. These results demonstrate a fabrication proof of concept for 3D-printed neural probes using geometry-defined metallization and selective Parylene encapsulation, providing a potential route toward scalable fabrication of 3D-printed bioelectronic microsystems
- Open Access
- 20 July 2026
- Published by Elsevier in Additive Manufacturing Letters
- Vol. 18
3D-printed penetrating neural probes with maskless metallization and encapsulation
- 20 July 2026
- Published by Elsevier in Additive Manufacturing Letters
- Vol. 18
Open Access3D-printed penetrating neural probes with maskless metallization and encapsulation
- Open Access
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 83446-83460
Intracranial Hemorrhage Classification From CT Scan Using Deep Learning and Bayesian Optimization
Intracranial hemorrhage is a medical condition that involves bleeding within the skull or brain tissue. It has mainly five subtypes - epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, intraparenchymal hemorrhage, and intraventricular hemorrhage. In order to ensure a successful outcome for a patient, a timely and accurate detection of intracranial hemorrhage is crucial. Despite this, there is a shortage of radiologists, especially in rural areas, which can lead to a delay in diagnosis. In this work, we proposed an automatic way of diagnosing intracranial hemorrhage from a CT scan. We have optimized the DenseNet architecture using Bayesian Optimization (BO) to diagnose intracranial hemorrhage effectively. Using BO, we identified the optimal learning rate, optimizer, and number of dense nodes for the DenseNet architecture. Our proposed model can analyse whether hemorrhage is present in a CT scan and, if it is present, what its subtype is. The optimized DenseNet model was able to achieve a very high accuracy of 98.02% on the test set. By ensuring accurate and reliable diagnoses, our method will assist doctors in making better-informed decisions and providing better care for their patients.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 83446-83460
Open AccessIntracranial Hemorrhage Classification From CT Scan Using Deep Learning and Bayesian Optimization
Intracranial hemorrhage is a medical condition that involves bleeding within the skull or brain tissue. It has mainly five subtypes - epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, intraparenchymal hemorrhage, and intraventricular hemorrhage. In order to ensure a successful outcome for a patient, a timely and accurate detection of intracranial hemorrhage is crucial. Despite this, there is a shortage of radiologists, especially in rural areas, which can lead to a delay in diagnosis. In this work, we proposed an automatic way of diagnosing intracranial hemorrhage from a CT scan. We have optimized the DenseNet architecture using Bayesian Optimization (BO) to diagnose intracranial hemorrhage effectively. Using BO, we identified the optimal learning rate, optimizer, and number of dense nodes for the DenseNet architecture. Our proposed model can analyse whether hemorrhage is present in a CT scan and, if it is present, what its subtype is. The optimized DenseNet model was able to achieve a very high accuracy of 98.02% on the test set. By ensuring accurate and reliable diagnoses, our method will assist doctors in making better-informed decisions and providing better care for their patients.