Peter S. Walker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter S. Walker has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Christopher P. Bell
Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY, USA
4 shared publicationsSally Arno
Department of Orthopaedic Surgery, NYU Hospital for Joint Diseases, New York, NY, USA
4 shared publicationsChih-Shing Wei
Cooper Union for the Advancement of Arts and Science, New York, NY
3 shared publicationsDaniel Hennessy
New York University Langone Orthopedic Hospital
3 shared publicationsGabriela Zapata
New York University Langone Orthopedic Hospital
3 shared publicationsGokce Yildirim
Department of Orthopaedic Surgery, New York University Hospital for Joint Diseases, New York, New York
3 shared publications
Latest Publications
- 15 March 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (8) , S340-S346
Achieving Specified Laxity in a Noncruciate Total Knee: A Laboratory Design Study
- 15 March 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (8) , S340-S346
Achieving Specified Laxity in a Noncruciate Total Knee: A Laboratory Design Study
- 1 June 2021
- Vol. 79 (2) , 115-123
Investigation of Foot Sensor Insoles for Measuring Functional Outcome After Total Knee Replacement
Background: To measure functional outcome, patient reported outcome measures (PROMS) are most often used but biomechanical tests can provide valuable supplementary data. The objective of this study was to investigate instrumented insoles for measuring ground-to-foot forces during basic activities. Methods: Three groups were evaluated: normal controls, preoperative, and postoperative total knees. The Knee Society Scoring System (KSS) Short Form was used, and with foot pressure sensor insoles, a timed-up-and-go (TUG) test and a sit-to-stand (STS) test was used. Results: Comparing preoperative to postoperative and control groups, there were significant differences in most parameters. There were no significant differences between controls and postoperative knees. Of the 33 correlation coefficients between three PROM parameters and six biomechanical parameters for the three groups, only five coefficients were greater than 0.5. Conclusions: The biomechanical data was substantially independent of the PROM data and provided additional functional evaluation. The most useful parameters were the left-right force ratios during sit-to stand (STS) and the timed-up-and-go (TUG) time.
- 1 June 2021
- Vol. 79 (2) , 115-123
Investigation of Foot Sensor Insoles for Measuring Functional Outcome After Total Knee Replacement
Background: To measure functional outcome, patient reported outcome measures (PROMS) are most often used but biomechanical tests can provide valuable supplementary data. The objective of this study was to investigate instrumented insoles for measuring ground-to-foot forces during basic activities. Methods: Three groups were evaluated: normal controls, preoperative, and postoperative total knees. The Knee Society Scoring System (KSS) Short Form was used, and with foot pressure sensor insoles, a timed-up-and-go (TUG) test and a sit-to-stand (STS) test was used. Results: Comparing preoperative to postoperative and control groups, there were significant differences in most parameters. There were no significant differences between controls and postoperative knees. Of the 33 correlation coefficients between three PROM parameters and six biomechanical parameters for the three groups, only five coefficients were greater than 0.5. Conclusions: The biomechanical data was substantially independent of the PROM data and provided additional functional evaluation. The most useful parameters were the left-right force ratios during sit-to stand (STS) and the timed-up-and-go (TUG) time.
- 13 March 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (12) , 2537-2545
The effect of total knee geometries on kinematics: An experimental study using a crouching machine
Obtaining anatomic knee kinematics after a total knee is likely to improve outcomes. We used a crouching machine to compare the kinematics of standard condylar designs with guided motion designs. The standard condylars included femoral sagittal radii with constant radius, J‐curve and G‐curve; the tibial surfaces were of low and high constraint. The guided motion designs were a medial pivot and a design with asymmetric condylar shapes and guiding surfaces. The machine had a flexion range from 0° to 125°, applied quadriceps and hamstring loading, and simulated the collateral soft tissues. The kinematics of all standard condylar knees were similar, showing only small anterior–posterior displacements and internal–external rotations. The two asymmetric designs showed posterior displacements during flexion, but less axial rotations than anatomic knees. The quadriceps forces throughout flexion were very similar between all designs, reflecting similar lever arms. It was concluded that standard condylar designs, even with variations in sagittal radii, are unlikely to reproduce anatomic kinematics. On the other hand, designs with asymmetric constraint between medial and lateral sides, and other guiding features, are likely to be the way forward. The mechanical testing method could be further improved by superimposing shear forces and torques during the flexion–extension motion, to include more stressful in vivo functional conditions.
- 13 March 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 39 (12) , 2537-2545
The effect of total knee geometries on kinematics: An experimental study using a crouching machine
Obtaining anatomic knee kinematics after a total knee is likely to improve outcomes. We used a crouching machine to compare the kinematics of standard condylar designs with guided motion designs. The standard condylars included femoral sagittal radii with constant radius, J‐curve and G‐curve; the tibial surfaces were of low and high constraint. The guided motion designs were a medial pivot and a design with asymmetric condylar shapes and guiding surfaces. The machine had a flexion range from 0° to 125°, applied quadriceps and hamstring loading, and simulated the collateral soft tissues. The kinematics of all standard condylar knees were similar, showing only small anterior–posterior displacements and internal–external rotations. The two asymmetric designs showed posterior displacements during flexion, but less axial rotations than anatomic knees. The quadriceps forces throughout flexion were very similar between all designs, reflecting similar lever arms. It was concluded that standard condylar designs, even with variations in sagittal radii, are unlikely to reproduce anatomic kinematics. On the other hand, designs with asymmetric constraint between medial and lateral sides, and other guiding features, are likely to be the way forward. The mechanical testing method could be further improved by superimposing shear forces and torques during the flexion–extension motion, to include more stressful in vivo functional conditions.
- 1 November 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 112, 110039
Principles of a 3D printed mechanical device for total knee balancing
- 1 November 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 112, 110039
Principles of a 3D printed mechanical device for total knee balancing
- 17 March 2020
- Published by Springer Nature
- p. 1-12
Introduction
- 1 July 2019
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 101-B (7_Supple_C) , 115-120
Feasibility of single-use 3D-printed instruments for total knee arthroplasty
Aims: This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods: Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results: Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion: The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120
- 1 July 2019
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 101-B (7_Supple_C) , 115-120
Feasibility of single-use 3D-printed instruments for total knee arthroplasty
Aims: This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods: Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results: Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion: The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120
- Open Access
- 1 June 2019
- Published by Elsevier in Arthroplasty Today
- Vol. 5 (2) , 197-201
Relationship between surgical balancing and outcome measures in total knees
- 1 June 2019
- Published by Elsevier in Arthroplasty Today
- Vol. 5 (2) , 197-201
Open AccessRelationship between surgical balancing and outcome measures in total knees
- 1 March 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 86, 117-124
Effects of femoral component placement on the balancing of a total knee at surgery
- 1 March 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 86, 117-124
Effects of femoral component placement on the balancing of a total knee at surgery