Daping Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daping Chen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Fuwang Wang
School of Mechanical Engineering, Northeast Electric Power University, Jilin, China
5 shared publications - Xiaolei Zhang
School of Mechanic Engineering, Northeast Electric Power University, Jilin 132012, China
4 shared publications - Rongrong Fu
Hebei Key Laboratory of Measurement Technology and Instrumentation, Yanshan University, Qinhuangdao, China
3 shared publications - Bin Lu
School of Electrical Engineering, Yanshan University, Qinhuangdao, China
1 shared publication - Eduardo Gerardo Moros
Department of Radiation Oncology Moffitt Cancer Center Tampa Florida USA
1 shared publication - Gal Shafirstein
Department of Cell Stress Biology Photodynamic Therapy Center Roswell Park Comprehensive Cancer Center Buffalo NY 14203 USA
1 shared publication
Latest Publications
- Open Access
Mental Fatigue Detection of Crane Operators Based on Electroencephalogram Signals Acquired by a Novel Rotary Switch-Type Semi-Dry Electrode Using Multifractal Detrend Fluctuation Analysis
The mental fatigue of crane operators can pose a serious threat to construction safety. To enhance the safety of crane operations on construction sites, this study proposes a rotary switch semi-dry electrode for detecting the mental fatigue of crane operators. This rotary switch semi-dry electrode overcomes the problems of the large impedance value of traditional dry electrodes, the cumbersome wet electrode operation, and the uncontrollable outflow of conductive liquid from traditional semi-dry electrodes. By designing a rotary switch structure inside the electrode, it allows the electrode to be turned on and used in motion, which greatly improves the efficiency of using the conductive fluid and prolongs the electrode’s use time. A conductive sponge was used at the electrode’s contact end with the skin, improving comfort and making it suitable for long-term wear. In addition, in this study, the multifractal detrend fluctuation analysis (MF-DFA) method was used to detect the mental fatigue state of crane operators. The results indicate that the MF-DFA is more responsive to the tiredness traits of individuals than conventional fatigue detection methods. The proposed rotary switch semi-dry electrode can quickly and accurately detect the mental fatigue of crane operators, provide support for timely warning or intervention, and effectively reduce the risk of accidents at construction sites, enhancing construction safety and efficiency.
Open AccessMental Fatigue Detection of Crane Operators Based on Electroencephalogram Signals Acquired by a Novel Rotary Switch-Type Semi-Dry Electrode Using Multifractal Detrend Fluctuation Analysis
The mental fatigue of crane operators can pose a serious threat to construction safety. To enhance the safety of crane operations on construction sites, this study proposes a rotary switch semi-dry electrode for detecting the mental fatigue of crane operators. This rotary switch semi-dry electrode overcomes the problems of the large impedance value of traditional dry electrodes, the cumbersome wet electrode operation, and the uncontrollable outflow of conductive liquid from traditional semi-dry electrodes. By designing a rotary switch structure inside the electrode, it allows the electrode to be turned on and used in motion, which greatly improves the efficiency of using the conductive fluid and prolongs the electrode’s use time. A conductive sponge was used at the electrode’s contact end with the skin, improving comfort and making it suitable for long-term wear. In addition, in this study, the multifractal detrend fluctuation analysis (MF-DFA) method was used to detect the mental fatigue state of crane operators. The results indicate that the MF-DFA is more responsive to the tiredness traits of individuals than conventional fatigue detection methods. The proposed rotary switch semi-dry electrode can quickly and accurately detect the mental fatigue of crane operators, provide support for timely warning or intervention, and effectively reduce the risk of accidents at construction sites, enhancing construction safety and efficiency.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38646-38657
Study on a Novel Flow-Controllable Semidry Electrode for EEG Signal Acquisition
Traditional electrodes often face a series of problems when collecting electroencephalogram (EEG) signals. The lack of conductive medium between the dry electrode and the skin results in high contact impedance, which degrades the quality of the collected signal. When the wet electrode is used, the conductive gel evaporates quickly, and the operation is complex. A conventional semi-dry electrode’s conductive fluid flow is ineffectively controlled, wasting conductive fluid in the process. To solve these concerns, this paper proposes a novel semi-dry electrode, which has a smaller contact impedance than the conventional dry electrode and is more portable than the wet electrode. The unique valve structure of the electrode allows the flow of conductive fluid to be controlled, which makes the electrode less conductive liquid than the conventional semi-dry electrode. In addition, the tip structure of the electrode is designed to pass through thick hair more effectively, ensuring that the conductive fluid is in full contact with the skin. This semi-dry electrode uses a bipolar electrode setup to collect EEG signals from construction equipment operators. The results show that the novel electrode has a strong correlation with the EEG signal features collected by the traditional wet electrode. The semi-dry electrode can effectively detect the mental fatigue state of construction equipment operators, and the classification accuracy is 99.16%.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (23) , 38646-38657
Study on a Novel Flow-Controllable Semidry Electrode for EEG Signal Acquisition
Traditional electrodes often face a series of problems when collecting electroencephalogram (EEG) signals. The lack of conductive medium between the dry electrode and the skin results in high contact impedance, which degrades the quality of the collected signal. When the wet electrode is used, the conductive gel evaporates quickly, and the operation is complex. A conventional semi-dry electrode’s conductive fluid flow is ineffectively controlled, wasting conductive fluid in the process. To solve these concerns, this paper proposes a novel semi-dry electrode, which has a smaller contact impedance than the conventional dry electrode and is more portable than the wet electrode. The unique valve structure of the electrode allows the flow of conductive fluid to be controlled, which makes the electrode less conductive liquid than the conventional semi-dry electrode. In addition, the tip structure of the electrode is designed to pass through thick hair more effectively, ensuring that the conductive fluid is in full contact with the skin. This semi-dry electrode uses a bipolar electrode setup to collect EEG signals from construction equipment operators. The results show that the novel electrode has a strong correlation with the EEG signal features collected by the traditional wet electrode. The semi-dry electrode can effectively detect the mental fatigue state of construction equipment operators, and the classification accuracy is 99.16%.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Study on a Novel Electrode With Automatic Replenishment of Conductive Fluid for Use in the Built Environment
There are some limitations in the use of traditional electroencephalogram (EEG) signal acquisition sensors. For example, the conductive paste of wet electrodes volatilizes faster and the operation process is cumbersome. However, the dry electrode has a large contact impedance value when it is used, which affects the quality of the collected signal. The traditional semi-dry electrode may cause a small movement of the electrode when the supplementary conductive solution is manually pressed, thus affecting the accuracy and stability of the signal. To address these issues, this study proposes a novel electrode that can automatically replenish the conductive liquid. The electrode can monitor the humidity of the electrode in real time through the humidity-sensitive material inside the electrode, and realize the automatic supplementation of conductive liquid to the electrode. This kind of electrode improves the efficiency of the conductive liquid, increases the stability of the acquisition signal, and realizes the function of long-term uninterrupted acquisition of EEG signals. In addition, to solve the problem of time-consuming and labor-consuming lifting alignment caused by the uncoordinated communication between the tower crane driver and the lower preform lifting operator, this study proposes a method to improve the efficiency of preform lifting alignment based on the deep residual shrinkage network (DRSN). This method can effectively classify the motor imagery (MI) EEG signals of the preform hoisting operator, and convert the classification results into the instructions of the tower crane, and finally realize the accurate movement and alignment of the preform. The novel electrode can effectively collect EEG signals in the real building environment, and prolong the effective use time compared with the traditional semi-dry electrode. The DRSN-based method shortens the time of preformed lifting and alignment, and improves efficiency. Compared with other traditional methods, the DRSN algorithm performs better in terms of classification accuracy and anti-noise performance.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Study on a Novel Electrode With Automatic Replenishment of Conductive Fluid for Use in the Built Environment
There are some limitations in the use of traditional electroencephalogram (EEG) signal acquisition sensors. For example, the conductive paste of wet electrodes volatilizes faster and the operation process is cumbersome. However, the dry electrode has a large contact impedance value when it is used, which affects the quality of the collected signal. The traditional semi-dry electrode may cause a small movement of the electrode when the supplementary conductive solution is manually pressed, thus affecting the accuracy and stability of the signal. To address these issues, this study proposes a novel electrode that can automatically replenish the conductive liquid. The electrode can monitor the humidity of the electrode in real time through the humidity-sensitive material inside the electrode, and realize the automatic supplementation of conductive liquid to the electrode. This kind of electrode improves the efficiency of the conductive liquid, increases the stability of the acquisition signal, and realizes the function of long-term uninterrupted acquisition of EEG signals. In addition, to solve the problem of time-consuming and labor-consuming lifting alignment caused by the uncoordinated communication between the tower crane driver and the lower preform lifting operator, this study proposes a method to improve the efficiency of preform lifting alignment based on the deep residual shrinkage network (DRSN). This method can effectively classify the motor imagery (MI) EEG signals of the preform hoisting operator, and convert the classification results into the instructions of the tower crane, and finally realize the accurate movement and alignment of the preform. The novel electrode can effectively collect EEG signals in the real building environment, and prolong the effective use time compared with the traditional semi-dry electrode. The DRSN-based method shortens the time of preformed lifting and alignment, and improves efficiency. Compared with other traditional methods, the DRSN algorithm performs better in terms of classification accuracy and anti-noise performance.
- 29 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Mental Fatigue Detection of Construction Equipment Operators Based on EEG Collected by a Novel Valve-Type Semidry Electrode Using Deep Residual Shrinkage Networks Under Real Construction Environment
Dry electrodes used for electroencephalography (EEG) signals acquisition are of good portability. However, the large impedance of the dry electrode often results in poor signal acquisition quality. Meanwhile, the preparation of wet electrodes in experiments is complex, and replenishing the conductive gel is not convenient. Therefore, based on the comprehensive consideration of the trade-off between wet and dry electrodes used for data acquisition, a novel valve-type semi-dry electrode is proposed. The semi-dry electrode has the advantages of convenient wearing and convenient replenishment of conductive liquid. In addition, this experiment is conducted in a real building construction environment, and the acquired EEG signals are highly susceptible to being mixed with various noises. In this study, a deep residual shrinkage networks (DRSN) algorithm with strong anti-noise ability is used to construct a recognition model of construction equipment operators’ mental fatigue using EEG-based features. The DRSN algorithm removes mixed noise and redundant features to improve the recognition accuracy of mental fatigue. These results show that the novel valve-type semi-dry electrode can collect EEG signals with fatigue characteristics just as well as the wet electrode. The ability to maintain small impedances for a long time can benefit long-period EEG signal acquisition. Additionally, the DRSN algorithm was used to classify the mental fatigue state of 12 subjects. The average classification accuracy is 99.59%; the average precision is 96.40%; the average recall is 97.45%; and the average F1 score is 96.93%. The DRSN algorithm outperforms existing approaches in terms of classification accuracy and noise resistance. This study developed the novel valve-type semi-dry electrode and the DRSN algorithm to successfully measure mental fatigue changes in construction equipment operators over an extended period in a real building construction setting.
- 29 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
Mental Fatigue Detection of Construction Equipment Operators Based on EEG Collected by a Novel Valve-Type Semidry Electrode Using Deep Residual Shrinkage Networks Under Real Construction Environment
Dry electrodes used for electroencephalography (EEG) signals acquisition are of good portability. However, the large impedance of the dry electrode often results in poor signal acquisition quality. Meanwhile, the preparation of wet electrodes in experiments is complex, and replenishing the conductive gel is not convenient. Therefore, based on the comprehensive consideration of the trade-off between wet and dry electrodes used for data acquisition, a novel valve-type semi-dry electrode is proposed. The semi-dry electrode has the advantages of convenient wearing and convenient replenishment of conductive liquid. In addition, this experiment is conducted in a real building construction environment, and the acquired EEG signals are highly susceptible to being mixed with various noises. In this study, a deep residual shrinkage networks (DRSN) algorithm with strong anti-noise ability is used to construct a recognition model of construction equipment operators’ mental fatigue using EEG-based features. The DRSN algorithm removes mixed noise and redundant features to improve the recognition accuracy of mental fatigue. These results show that the novel valve-type semi-dry electrode can collect EEG signals with fatigue characteristics just as well as the wet electrode. The ability to maintain small impedances for a long time can benefit long-period EEG signal acquisition. Additionally, the DRSN algorithm was used to classify the mental fatigue state of 12 subjects. The average classification accuracy is 99.59%; the average precision is 96.40%; the average recall is 97.45%; and the average F1 score is 96.93%. The DRSN algorithm outperforms existing approaches in terms of classification accuracy and noise resistance. This study developed the novel valve-type semi-dry electrode and the DRSN algorithm to successfully measure mental fatigue changes in construction equipment operators over an extended period in a real building construction setting.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 17891-17900
A Novel Semi-Dry Electrode Suitable for Collecting EEG Data for Detecting Driving Fatigue in Long-Period Driving Case
To address issues with the conventional wet electrode during long-period experiments, which include signal acquisition distortion caused by conductive liquid volatilization and drying, as well as time-consuming conductive liquid refilling, this study introduced a portable semi-dry electrode that allows for convenient conductive liquid replenishment at any time. The new semi-dry electrode combines the advantages of small impedance value of wet electrode and convenient installation and disassembly of dry electrode. And this electrode is suitable for collecting human electroencephalogram (EEG) for a long time, such as detecting the EEG characteristics of drivers who drive vehicles for a long time. In addition, since the order recurrence plot (ORP) does not require for signal stability, data length, and signal-to-noise ratio, this paper used the method to analyze the driving fatigue characteristics of the subjects. Firstly, the ORP method was used to map EEG signals collected by the two types of electrodes, and the ORP was performed by recurrence quantitative analysis (RQA). Then, two quantitative parameters, determinism (DET) and average diagonal line length (DLL), were selected to analyze the fatigue driving characteristics of the subjects. The results showed that with the increase of fatigue degree of the subjects, the blue and white squares in ORP from EEG signals collected by the two kinds of electrodes gradually increased, with a clearer texture and a more organized arrangement. Meanwhile, the quantization parameters DET and DLL increase gradually as well, which can effectively express the law of driving fatigue change. The results of this study are helpful to address the problems such as the difficulty of supplementing conductive fluid with traditional wet electrodes, and to address the problem of easy interference in EEG acquisition experiments in complex environments.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 17891-17900
A Novel Semi-Dry Electrode Suitable for Collecting EEG Data for Detecting Driving Fatigue in Long-Period Driving Case
To address issues with the conventional wet electrode during long-period experiments, which include signal acquisition distortion caused by conductive liquid volatilization and drying, as well as time-consuming conductive liquid refilling, this study introduced a portable semi-dry electrode that allows for convenient conductive liquid replenishment at any time. The new semi-dry electrode combines the advantages of small impedance value of wet electrode and convenient installation and disassembly of dry electrode. And this electrode is suitable for collecting human electroencephalogram (EEG) for a long time, such as detecting the EEG characteristics of drivers who drive vehicles for a long time. In addition, since the order recurrence plot (ORP) does not require for signal stability, data length, and signal-to-noise ratio, this paper used the method to analyze the driving fatigue characteristics of the subjects. Firstly, the ORP method was used to map EEG signals collected by the two types of electrodes, and the ORP was performed by recurrence quantitative analysis (RQA). Then, two quantitative parameters, determinism (DET) and average diagonal line length (DLL), were selected to analyze the fatigue driving characteristics of the subjects. The results showed that with the increase of fatigue degree of the subjects, the blue and white squares in ORP from EEG signals collected by the two kinds of electrodes gradually increased, with a clearer texture and a more organized arrangement. Meanwhile, the quantization parameters DET and DLL increase gradually as well, which can effectively express the law of driving fatigue change. The results of this study are helpful to address the problems such as the difficulty of supplementing conductive fluid with traditional wet electrodes, and to address the problem of easy interference in EEG acquisition experiments in complex environments.
- 2 June 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part8) , 3432
WE-D-201C-04: SonoKnife - Feasibility of Line-Focused Ultrasound for Thermal Ablation
- 2 June 2010
- Published by Wiley in Medical Physics
- Vol. 37 (6Part8) , 3432
WE-D-201C-04: SonoKnife - Feasibility of Line-Focused Ultrasound for Thermal Ablation