Haohan Tao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haohan Tao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Huanguo Chen
3 shared publicationsPeng Jia
3 shared publications- Xiangyu Wang
College of Mechanical and Electrical Engineering, Yantai Research Institute of Harbin Engineering University, Yantai 264006, China
3 shared publications Liquan Wang
2 shared publicationsGang Wang
1 shared publication- Gang Wang
National Key Laboratory of Autonomous Marine Vehicle Technology, Harbin Engineering University, Harbin, China
1 shared publication
Latest Publications
- Open Access
- 27 May 2026
- Published by Elsevier in SSRN Electronic Journal
Anti-Load Performance Evaluation Method for Electro-Hydrostatic Actuators Based on Physics-Embedded Attention Mechanism
High-precision performance degradation evaluation of electro-hydrostatic actuators (EHAs) is critical for aerospace reliability. Among all potential hardware degradation, internal leakage stands out as the most frequent and dominant fault in EHA systems. However, existing methods often fail in dynamic flight environments, where genuine internal leakage signatures are deeply entangled with external variable load disturbances. To address this load-fault coupling challenge, this study proposes an Anti-load Performance Evaluation Method. Firstly, an EHA dynamic model is established to analytically derive a Baseline Contribution Score (BCS), explicitly quantifying the relative sensitivities of multi-source signals to faults versus loads. Then after a dual-screening purification of statistical features, the BCS is deployed as a dual-purpose physical constraint linking the subsequent core modules. It first functions as a physical prior in a Physics-Embedded Channel Attention Mechanism to adaptively highlight fault signatures while suppressing load noise, and then acts as a regularization penalty within a Correlation-Regularized Stacked Autoencoder to constrain the deep fusion process. Driven by this sequential BCS guidance, the network ultimately condenses these refined representations into a highly robust, anti-load 1D Health Indicator. Validated through simulations and physical testbench experiments, the ACFN successfully disentangles complex coupled signals into a linearly separable manifold. It achieves a superior diagnostic accuracy of 95.24% under the 3 kN load. This physics-guided framework effectively bridges the gap between mechanistic interpretability and deep learning, providing a highly robust solution for EHA health management.
- 27 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAnti-Load Performance Evaluation Method for Electro-Hydrostatic Actuators Based on Physics-Embedded Attention Mechanism
High-precision performance degradation evaluation of electro-hydrostatic actuators (EHAs) is critical for aerospace reliability. Among all potential hardware degradation, internal leakage stands out as the most frequent and dominant fault in EHA systems. However, existing methods often fail in dynamic flight environments, where genuine internal leakage signatures are deeply entangled with external variable load disturbances. To address this load-fault coupling challenge, this study proposes an Anti-load Performance Evaluation Method. Firstly, an EHA dynamic model is established to analytically derive a Baseline Contribution Score (BCS), explicitly quantifying the relative sensitivities of multi-source signals to faults versus loads. Then after a dual-screening purification of statistical features, the BCS is deployed as a dual-purpose physical constraint linking the subsequent core modules. It first functions as a physical prior in a Physics-Embedded Channel Attention Mechanism to adaptively highlight fault signatures while suppressing load noise, and then acts as a regularization penalty within a Correlation-Regularized Stacked Autoencoder to constrain the deep fusion process. Driven by this sequential BCS guidance, the network ultimately condenses these refined representations into a highly robust, anti-load 1D Health Indicator. Validated through simulations and physical testbench experiments, the ACFN successfully disentangles complex coupled signals into a linearly separable manifold. It achieves a superior diagnostic accuracy of 95.24% under the 3 kN load. This physics-guided framework effectively bridges the gap between mechanistic interpretability and deep learning, providing a highly robust solution for EHA health management.
- Open Access
- 13 April 2026
- Published by Elsevier in SSRN Electronic Journal
Hydraulic System Compound Fault Diagnosis Based On Feature Decoupling and Uncertainty-Aware Evidential Fusion
Compound fault diagnosis in complex hydraulic systems is challenging due to the strong coupling of fault features and the scarcity of training samples. This paper proposes a novel diagnostic method that integrates a two-stage feature decoupling mechanism with an uncertainty-aware evidential fusion framework, implemented through a D-S(Dempster-Shafer) theory-enhanced convolutional neural network (DSNN). The method first performs preliminary decoupling by decomposing the original diagnostic task into several sub-tasks that identify fault groups with maximized inter-group feature distances, where soft grouping is adopted to account for clustering uncertainty caused by feature overlap. For each subtask, a dedicated submodel then optimizes feature representations according to the distribution of its fault groups, achieving fine-grained decoupling. In the fusion stage, a differentiable D-S evidence layer combines the basic probability from all sub-tasks, quantifying prediction uncertainty via conflict factors to perform robust fault reasoning. The entire framework can be trained end-to-end, enabling collaborative optimization of decoupling and fusion. Experimental results on a subsea control module (SCM) hydraulic test rig and an open-source hydraulic dataset demonstrate that the proposed DSNN achieves superior diagnostic accuracy and robustness compared with state-of-the-art methods, especially under limited training samples.
- 13 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHydraulic System Compound Fault Diagnosis Based On Feature Decoupling and Uncertainty-Aware Evidential Fusion
Compound fault diagnosis in complex hydraulic systems is challenging due to the strong coupling of fault features and the scarcity of training samples. This paper proposes a novel diagnostic method that integrates a two-stage feature decoupling mechanism with an uncertainty-aware evidential fusion framework, implemented through a D-S(Dempster-Shafer) theory-enhanced convolutional neural network (DSNN). The method first performs preliminary decoupling by decomposing the original diagnostic task into several sub-tasks that identify fault groups with maximized inter-group feature distances, where soft grouping is adopted to account for clustering uncertainty caused by feature overlap. For each subtask, a dedicated submodel then optimizes feature representations according to the distribution of its fault groups, achieving fine-grained decoupling. In the fusion stage, a differentiable D-S evidence layer combines the basic probability from all sub-tasks, quantifying prediction uncertainty via conflict factors to perform robust fault reasoning. The entire framework can be trained end-to-end, enabling collaborative optimization of decoupling and fusion. Experimental results on a subsea control module (SCM) hydraulic test rig and an open-source hydraulic dataset demonstrate that the proposed DSNN achieves superior diagnostic accuracy and robustness compared with state-of-the-art methods, especially under limited training samples.
- 23 April 2024
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 248
Reliability analysis of subsea control module based on dynamic Bayesian network and digital twin
- 23 April 2024
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 248
Reliability analysis of subsea control module based on dynamic Bayesian network and digital twin
- Top Cited PapersOpen Access
Real-Time Fault Diagnosis for Hydraulic System Based on Multi-Sensor Convolutional Neural Network
This paper proposed a real-time fault diagnostic method for hydraulic systems using data collected from multiple sensors. The method is based on a proposed multi-sensor convolutional neural network (MS-CNN) that incorporates feature extraction, sensor selection, and fault diagnosis into an end-to-end model. Both the sensor selection process and fault diagnosis process are based on abstract fault-related features learned by a CNN deep learning model. Therefore, compared with the traditional sensor-and-feature selection method, the proposed MS-CNN can find the sensor channels containing higher-level fault-related features, which provides two advantages for diagnosis. First, the sensor selection can reduce the redundant information and improve the diagnostic performance of the model. Secondly, the reduced number of sensors simplifies the model, reducing communication burden and computational complexity. These two advantages make the MS-CNN suitable for real-time hydraulic system fault diagnosis, in which the multi-sensor feature extraction and the computation speed are both significant. The proposed MS-CNN approach is evaluated experimentally on an electric-hydraulic subsea control system test rig and an open-source dataset. The proposed method shows obvious superiority in terms of both diagnosis accuracy and computational speed when compared with traditional CNN models and other state-of-the-art multi-sensor diagnostic methods.
Top Cited PapersOpen AccessReal-Time Fault Diagnosis for Hydraulic System Based on Multi-Sensor Convolutional Neural Network
This paper proposed a real-time fault diagnostic method for hydraulic systems using data collected from multiple sensors. The method is based on a proposed multi-sensor convolutional neural network (MS-CNN) that incorporates feature extraction, sensor selection, and fault diagnosis into an end-to-end model. Both the sensor selection process and fault diagnosis process are based on abstract fault-related features learned by a CNN deep learning model. Therefore, compared with the traditional sensor-and-feature selection method, the proposed MS-CNN can find the sensor channels containing higher-level fault-related features, which provides two advantages for diagnosis. First, the sensor selection can reduce the redundant information and improve the diagnostic performance of the model. Secondly, the reduced number of sensors simplifies the model, reducing communication burden and computational complexity. These two advantages make the MS-CNN suitable for real-time hydraulic system fault diagnosis, in which the multi-sensor feature extraction and the computation speed are both significant. The proposed MS-CNN approach is evaluated experimentally on an electric-hydraulic subsea control system test rig and an open-source dataset. The proposed method shows obvious superiority in terms of both diagnosis accuracy and computational speed when compared with traditional CNN models and other state-of-the-art multi-sensor diagnostic methods.
- 18 August 2023
- Published by Elsevier in Measurement
- Vol. 221
A digital twin-based fault diagnostic method for subsea control systems
- 18 August 2023
- Published by Elsevier in Measurement
- Vol. 221
A digital twin-based fault diagnostic method for subsea control systems