HLHaijun Luo

Haijun Luo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haijun Luo has a total of 68 co-authors. Here are the top co-authors by number of shared publications:

  • Fang Wu

    Chongqing Key Laboratory of Interface Physics in Energy Conversion, College of Physics, Chongqing University, Chongqing 400044, China

    5 shared publications
  • Liang Fang

    Chongqing Key Laboratory of Interface Physics in Energy Conversion, College of Physics, Chongqing University, Chongqing 400044, China

    4 shared publications
  • Honglin Li

    College of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, China

    3 shared publications
  • Lizhong Yao

    College of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, China

    3 shared publications
  • Shufang Zhang

    College of AI and BigData, Chongqing Polytechnic University of Electronic Technology, Chongqing, 401331, P.R. China

    3 shared publications
  • Yuting Cui

    College of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, P.R. China

    3 shared publications

Latest Publications

  • Open Access

    Multispectral PPG Sensing Framework for Noninvasive Glucose Prediction via Multi-Feature Fusion and Micro-Environmental Compensation

    by Lin Huang, Jie Wang, Yuanshuang Fan, Jiansen Lan, Haijun Luo, Rui Wang

    Noninvasive blood glucose prediction using near-infrared spectroscopy remains challenging due to weak glucose-specific absorption, tissue variability, and environmental interference. This study proposes a multispectral photoplethysmography (PPG)-based framework integrating multi-feature fusion, local temperature and humidity compensation, and machine learning regression. The system employs four near-infrared wavelengths (940, 1300, 1550, and 1650 nm) while simultaneously measuring finger contact-site temperature (T) and local relative humidity (H) within the finger clip. A 39-dimensional feature set incorporating optical ratios, pulse-wave morphology, frequency-domain descriptors, participant characteristics, and environmental parameters was constructed. Among six optimized regression models, Extreme Gradient Boosting (XGBoost) achieved the best performance in group-isolated 10-fold cross-validation, with R2 = 0.9135, root mean square error (RMSE) = 0.2991, and mean absolute relative difference (MARD) = 2.71%. Clarke error grid analysis (CEGA) showed that 97% of predictions fell within zone A and 100% within zones A and B. Feature ablation demonstrated that local temperature and humidity measurements improved prediction accuracy, with humidity providing a greater improvement than temperature. SHapley Additive exPlanations (SHAP) analysis quantified the contributions of optical, environmental, and participant-level features. A separate session-holdout evaluation yielded R2 = 0.7261 and MARD = 6.07%. These findings highlight the potential of the proposed framework for noninvasive glucose prediction. However, the small, predominantly healthy cohort and limited glucose range constrain generalizability, necessitating validation in larger, more diverse populations to establish performance in previously unseen participants and assess clinical applicability.

  • Three-dimensional simulation of vapor-layer formation and layered structure near a coaxial bipolar electrode in conductive saline solution

    by Yuxia Kou, Haijun Luo, Jiansen Lan, Bin Guo, Kangyu Wang

    Vapor-layer formation and layered structure are important features of electrothermal phase transition in conductive saline solution near a bipolar electrode. To examine the spatial formation process and internal structure of the vapor layer, a three-dimensional electro–thermal–phase-transition model was implemented for a coaxial bipolar electrode under bipolar excitation. The numerical implementation couples electric conduction, Joule heating, transient heat transfer, temperature-dependent conductivity, and a smoothed liquid–vapor transition, with particular emphasis on resolving the spatial growth sequence of the vapor layer. Gas-phase-fraction thresholds were used to define the total vapor-layer thickness, vapor-dominated thickness, and liquid–vapor transition-region thickness. The results show that localized Joule heating near the annular active electrode causes vaporization to initiate preferentially at both ends of the active-electrode region. The vaporized regions then extend toward the middle and merge into a continuous layer. The formed vapor layer is not a sharp gas–liquid interface, but consists of a vapor-dominated region and a liquid–vapor transition region. At the selected central reference position, the total vapor-layer thickness and vapor-dominated thickness stabilize at approximately 120 μ m and 39 μ m, respectively, indicating that the liquid–vapor transition region occupies a considerable part of the local vapor-layer structure. The low-conductivity vapor layer further modifies the local electric-field distribution, suggesting a coupling between phase-transition-induced conductivity changes and electric-field redistribution. These results provide a geometry-specific numerical characterization of vapor-layer formation and layered structural evolution near a coaxial bipolar electrode in conductive saline solution.

  • A high sensitive, fast response optical detection system of thermal decomposition nanoparticles based on Mie scattering

    by Bin Guo, Haijun Luo, Jian Zhang, Aichao Yang, Kangyu Wang

    This work presents a Mie scattering-based optical design for detecting thermal decomposition nanoparticles generated during the pre-smoldering stage of material overheating. When subjected to mild thermal stress, materials such as cellulose-based office paper and enameled wire release sub–10 nm thermal decomposition nanoparticles prior to visible smoke formation. Through a simplified pneumatic expansion process, these particles grow into condensation nuclei detectable by a 650 nm laser scattering system. The optical chamber employs a right-angle scattering geometry optimized for stable angular response and reduced refractive index dependence. Both theoretical and experimental analyses confirm that the scattering intensity increases linearly with temperature in the early thermal decomposition stage, enabling quantitative identification of overheating before macroscopic combustion. The proposed design demonstrates high sensitivity, fast response, and non-contact measurement capability, offering a promising optical approach for early thermal diagnostics and nanoparticle characterization based on Mie scattering physics.

  • A Spatiotemporal Data-Driven Framework for Acoustic Signal-Based Natural Gas Pipeline Leak Detection

    by Lizhong Yao, Lu Zhang, Ling Wang, Rui Li, Haijun Luo

    Existing methods for natural gas pipeline leak detection primarily rely on feature extraction and fault classification based on Euclidean data, which often overlook the potential spatiotemporal correlations present in leak signals. This limitation restricts the development of high-precision fault identification models. To address this issue, a Spatio-Temporal Data-Driven Framework (STDDF) for acoustic signal-based natural gas pipeline leak detection is proposed. The framework begins with the application of a percentile-based cosine similarity measure to the acoustic sensor data, transforming it into a graph structure that captures both topological and temporal correlations. Subsequently, a full-graph mean aggregation method is introduced, utilizing a graph sample and aggregation network to enhance the representation of leak signal features. This approach overcomes the limitations of single-node features in capturing the spatial complexity of pipeline leaks. Furthermore, a gated recurrent unit is employed to process the time-series data, effectively capturing the temporal dynamics of leak signals. Validation experiments conducted on a pipeline leak detection platform demonstrate that the STDDF model significantly outperforms traditional deep learning methods, achieving a fault identification accuracy of up to 99 %.


  • Enhancing both the long-term stability and methylene blue adsorption performance of TiVCTxvia a facile antioxidation treatment

    by Xianliang Ren, Liang Fang, Yi Hu, Fang Wu, Gaobin Liu, Shufang Zhang, Haijun Luo

    OA, SC, and TA were used to treat TiVCTx for stability improvement. The maximum adsorption capacity of TA-TiVCTx reaches 8061.03 mg g−1. After being stored for 14 days, TA-TiVCTx still maintains an adsorption capacity of 3887.28 mg g−1.


  • Design of a playable spherical grip strength detection system based on a PVDF flexible sensor

    by Aichao Yang, Rui Song, Xue Wang, Haijun Luo

    Grip strength is a crucial indicator for assessing individual health and muscle function, reflecting the level of upper limb strength development. Current grip strength detection devices, while able to accurately assess the magnitude of grip strength, do not integrate well into daily life and have certain limitations in unobtrusive detection during individual activities. Inspired by elderly individuals playing with walnuts in their hands to improve hand blood circulation, clear meridians, and prevent cardiovascular diseases, this work designs a playable spherical grip strength detection (PSGD) system based on polyvinylidene fluoride (PVDF) flexible sensor. The PVDF sensor has a vertical pressure sensitivity of 3.955 V/N and can respond to vertical pressures in the 0–15 Hz frequency range, maintaining stable output over more than 2000 cycles. The PSGD system consists of a spherical shell, a PVDF flexible sensor, a data collection and transmission module, and a data reception and display module, enabling effective collection, processing, transmission, display, and storage of grip strength signals during playing. The PSGD system can respond excellently to grip strength signals, with the magnitude of the grip strength positively correlating with the output voltage signal. It can also distinguish the grip strength differences between individuals and has excellent output stability. The PSGD system holds broad application prospects in fields such as rehabilitative medicine and elderly health management.


  • Open Access

    Enhancing Methylene Blue Adsorption Performance of Ti3C2Tx@Sodium Alginate Foam Through Pore Structure Regulation

    by Yi Hu, Hongwei Wang, Xianliang Ren, Fang Wu, Gaobin Liu, Shufang Zhang, Haijun Luo, Liang Fang

    Pore structural regulation is expected to be a facile way to enhance the adsorption performance of MXene. In this work, spherical foam composites consisting of Ti3C2Tx and sodium alginate (SA) were synthesized via a vacuum freeze-drying technique. By varying the solution volume of Ti3C2Tx, four distinct Ti3C2Tx@SA spherical foams with honeycomb-like and lamellar structures with a pore diameter in the range of 100–300 μm were fabricated. Their methylene blue (MB) adsorption performances were then systematically compared. The results revealed that the honeycomb-like porous-structured spherical foams have a significantly higher adsorption capacity than their lamellar counterparts. Notably, the Ti3C2Tx@SA honeycomb-like porous foam exhibited a remarkable maximum adsorption capacity (qm) of 969 mg/g, positioning it at the forefront of MB adsorbent materials. Respective analysis of the adsorption kinetics, thermodynamics, and isotherm model indicated that this MB adsorption of Ti3C2Tx@SA honeycomb-like porous foam is characterized to be a physical, endothermic, and monolayer adsorption. The Ti3C2Tx@SA honeycomb-like porous foam also demonstrated excellent resistance to ion interference and good reusability, further attesting to its substantial potential for practical applications. X-ray photoelectron spectroscopy (XPS) analysis was employed to elucidate the adsorption mechanism, which was found to involve the synergistic effect of electrostatic adsorption and amidation reaction. This work not only offers new avenues for the development of high-performance adsorption materials but also provides crucial insights into the structural design and performance optimization of porous materials.


  • A microsphere-structure flexible pressure sensor for monitoring keyboard typing behavior

    by Rui Song, Yi Huang, Xue Wang, Haijun Luo

    Keyboard input is a commonplace activity in daily work that greatly enhances office efficiency. However, wrong typing posture over a prolonged period can lead to tenosynovitis or even tenosynovial cysts. Flexible sensors are widely utilized in human motion detection, but further in-depth research is required to identify typing posture accurately. Herein, a triboelectric-based pressure sensor with a microsphere structure was developed in this paper. Microsphere structures were fabricated onto the surface of silica gel (SG) to increase the friction coefficient and enhance the sensor’s performance. To establish a tight fit between the sensor and the skin, a flexible and adhesive polyacrylamide hydrogel was prepared. The microsphere-structured sensor holds a sensitivity of 0.903 V/N and a frequency response range of 0-20 Hz. It also exhibits good mechanical stability up to 18,000 cycles. It can monitor not only large-scale movements but also subtle muscle activities. By affixing the sensor to the skin surface on the wrist, it can effectively capture the motion signals generated during an individual’s typing and ascertain the correctness of the typing posture. This work provides technical support for the early prevention of tenosynovitis and tenosynovial cysts and exhibits promising applications in the long-term correction of typing posture.


  • Open Access

    Application of two-dimensional chaotic system and implementation of DSP

    by Ying-Ying Wang, Hai-Jun Luo

    Given that the limited complexity of most current 2D maps undermines chaos-based practical applications, this paper proposes a 2D Logical Cosine Coupled Map (2D-LSCCM) and compares the bifurcation maps, Lyapunov exponent spectrum, and spectral entropy complexity of the classical 2D chaos model. Based on this model, this paper proposes an image encryption scheme using ascending alignment permutation and XOR pixel diffusion algorithm. After a series of tests, such as chi-square test, anti-attack test, key sensitivity test, and correlation test, the simulation findings show that the chaotic system proposed in this paper has excellent security performance compared with other systems. Moreover, a hardware platform based on DSP (Digital Signal Processing) and NIST test have been developed to analyze and test chaotic sequences.