RKRandhir Kumar

Randhir Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Randhir Kumar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fabrication and mechanical characterization of hydrogel-based 3D cell-like structures

    by Randhir Kumar, Dustin Dzikonski, Elena Bekker, Robert Vornhusen, Valerio Vitali, Jörg Imbrock, Cornelia Denz

    In this article, we demonstrate the fabrication of 3D cell-like structures using a femtosecond laser-based two-photon polymerization technique. By employing poly(ethylene glycol) diacrylate monomers as a precursor solution, we fabricate 3D hemispheres that resemble morphological and biomechanical characteristics of natural cells. We employ an optical tweezers-based microrheology technique to measure the viscoelastic properties of the precursor solutions inside and outside the structures. In addition, we demonstrate the interchangeability of the precursor solution within fabricated structures without impairing the microstructures. The combination of two-photon polymerization and microrheological measurements by optical tweezers demonstrated here represents a powerful toolbox for future investigations into cell mimic and artificial cell studies.


  • Open Access

    Multi-frequency passive and active microrheology with optical tweezers

    by Randhir Kumar, Valerio Vitali, Timo Wiedemann, Robert Meissner, Paolo Minzioni, Cornelia Denz

    Optical tweezers have attracted significant attention for microrheological applications, due to the possibility of investigating viscoelastic properties in vivo which are strongly related to the health status and development of biological specimens. In order to use optical tweezers as a microrheological tool, an exact force calibration in the complex system under investigation is required. One of the most promising techniques for optical tweezers calibration in a viscoelastic medium is the so-called active–passive calibration, which allows determining both the trap stiffness and microrheological properties of the medium with the least a-priori knowledge in comparison to the other methods. In this manuscript, we develop an optimization of the active–passive calibration technique performed with a sample stage driving, whose implementation is more straightforward with respect to standard laser driving where two different laser beams are required. We performed microrheological measurements over a broad frequency range in a few seconds implementing an accurate multi-frequency driving of the sample stage. The optical tweezers-based microrheometer was first validated by measuring water, and then exemplarily applied to more viscous medium and subsequently to a viscoelastic solution of methylcellulose in water. The described method paves the way to microrheological precision metrology in biological samples with high temporal- and spatial-resolution allowing for investigation of even short time-scale phenomena.


  • Fast and Accurate Multi-frequency Stage Driving Active-passive Calibration of Optical Tweezers for Microrheology of Complex Fluids

    by Randhir Kumar, Valerio Vitali, Cornelia Denz

    Optical tweezers-based methods have been widely used for microrheological applications from simple to complex fluids. We report here an optical tweezers microrheology approach based on multi-frequency stage driving for viscoelasticity measurements in complex fluids.