Yan Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yan Zhao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Caige Xue
Henan International Joint Laboratory of New Civil Engineering Structure, School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
1 shared publication - Dening Guo
Henan International Joint Laboratory of New Civil Engineering Structure, School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
1 shared publication - Jia Li
Henan International Joint Laboratory of New Civil Engineering Structure, School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
1 shared publication - Jiale Wang
Henan International Joint Laboratory of New Civil Engineering Structure, School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
1 shared publication - Jianqun Jiang
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
1 shared publication Shuai Fu
Luoyang Institute of Science and Technology, Luoyang, China
1 shared publication
Latest Publications
- Open Access
Electrical Energy Storage from Low-Grade Heat Using Reduced Graphene Oxide–Carbon Nanotube Composite Materials
The conversion of low-grade heat into storable electrical energy using nanoporous carbon materials represents an efficient energy harvesting strategy. In this study, a reduced graphene oxide (RGO) and carbon nanotube (CNT) composite with a rich microporous structure was synthesized. A symmetrical thermoelectric cell was constructed to harvest thermal energy. The application of a temperature difference (ΔT) generated a stable equilibrium voltage (Us), which scaled linearly with ΔT. The resulting thermoelectric coefficient (Us/ΔT) increased markedly with the carbon nanotube (CNT) content, underscoring the effectiveness of CNT incorporation for improving thermoelectric properties. It also shows a non-monotonic dependence on KCl concentration, first increasing and then decreasing, with a maximum value of 4.17 mV/°C achieved in 0.1 M KCl using the RGO-5%CNTs electrode. When connected to an external load, the discharge voltage and current decay rapidly before stabilizing within seconds. Circuit analysis reveals that the incorporation of CNTs reduces internal resistance and increases the equivalent capacitance. Although instantaneous discharge power declines quickly, the addition of CNTs elevates its initial value and slows the decay rate. Both the average output power and thermoelectric conversion efficiency improve with increasing ΔT and are further enhanced at higher CNT content. Overall, the RGO-CNT composite demonstrates significantly superior thermoelectric performance compared to pure RGO.
Open AccessElectrical Energy Storage from Low-Grade Heat Using Reduced Graphene Oxide–Carbon Nanotube Composite Materials
The conversion of low-grade heat into storable electrical energy using nanoporous carbon materials represents an efficient energy harvesting strategy. In this study, a reduced graphene oxide (RGO) and carbon nanotube (CNT) composite with a rich microporous structure was synthesized. A symmetrical thermoelectric cell was constructed to harvest thermal energy. The application of a temperature difference (ΔT) generated a stable equilibrium voltage (Us), which scaled linearly with ΔT. The resulting thermoelectric coefficient (Us/ΔT) increased markedly with the carbon nanotube (CNT) content, underscoring the effectiveness of CNT incorporation for improving thermoelectric properties. It also shows a non-monotonic dependence on KCl concentration, first increasing and then decreasing, with a maximum value of 4.17 mV/°C achieved in 0.1 M KCl using the RGO-5%CNTs electrode. When connected to an external load, the discharge voltage and current decay rapidly before stabilizing within seconds. Circuit analysis reveals that the incorporation of CNTs reduces internal resistance and increases the equivalent capacitance. Although instantaneous discharge power declines quickly, the addition of CNTs elevates its initial value and slows the decay rate. Both the average output power and thermoelectric conversion efficiency improve with increasing ΔT and are further enhanced at higher CNT content. Overall, the RGO-CNT composite demonstrates significantly superior thermoelectric performance compared to pure RGO.
- Open Access
- 19 August 2023
- Published by Wiley in Advances in Civil Engineering
- Vol. 2023, 1-15
Fatigue Life Evaluation of Wind Turbine Tower Based on Measured Data
Fatigue life is a crucial design factor which dictates the safe operation of the wind turbines, but it is influenced by uncertain factors such as environmental loads, analytical models, material properties, and manufacturing methods. In this study, a 1.5 MW wind turbine was monitored in operation to understand the fatigue mechanism and enhance wind turbine design. The influence of different operating conditions on fatigue damage was analyzed by correlating strain monitoring data with supervisory control and data acquisition (SCADA) data. Furthermore, a fatigue evaluation method based on measured strain data was proposed. Fatigue damage increases with the increase of wind and rotation speed. More than 50% of the damage occurred at the rated rotation speed state, the corresponding wind speed was greater than the rated wind speed and the pitch control system was active. The findings of this study provide insights for investigating the real fatigue state of similar wind turbine towers and improving the return on investment by closely estimating their service life.
- 19 August 2023
- Published by Wiley in Advances in Civil Engineering
- Vol. 2023, 1-15
Open AccessFatigue Life Evaluation of Wind Turbine Tower Based on Measured Data
Fatigue life is a crucial design factor which dictates the safe operation of the wind turbines, but it is influenced by uncertain factors such as environmental loads, analytical models, material properties, and manufacturing methods. In this study, a 1.5 MW wind turbine was monitored in operation to understand the fatigue mechanism and enhance wind turbine design. The influence of different operating conditions on fatigue damage was analyzed by correlating strain monitoring data with supervisory control and data acquisition (SCADA) data. Furthermore, a fatigue evaluation method based on measured strain data was proposed. Fatigue damage increases with the increase of wind and rotation speed. More than 50% of the damage occurred at the rated rotation speed state, the corresponding wind speed was greater than the rated wind speed and the pitch control system was active. The findings of this study provide insights for investigating the real fatigue state of similar wind turbine towers and improving the return on investment by closely estimating their service life.
- 1 March 2022
- Published by Springer Nature in Soil Mechanics and Foundation Engineering
- Vol. 59 (1) , 77-84
Theoretical Calculations and Field Measurements of the Earth Pressure in the Jinci Tunnel
- 1 March 2022
- Published by Springer Nature in Soil Mechanics and Foundation Engineering
- Vol. 59 (1) , 77-84
Theoretical Calculations and Field Measurements of the Earth Pressure in the Jinci Tunnel