Mao-Yi Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mao-Yi Yang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Li-Wei Hung
Department of Orthopedic Surgery, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 111045, Taiwan
3 shared publications Chen-Yu Wang
1 shared publication- Chiung-Hui Liu
Doctoral Program in Tissue Engineering and Regenerative Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan
1 shared publication - Chui-Jia Farn
Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei 100, Taiwan
1 shared publication Chun-Chiao Chen
1 shared publication- Hsien‐Chun Tseng
Department of Radiation Oncology Chung Shan Medical University Hospital Taichung Taiwan
1 shared publication
Latest Publications
- Open Access
- 15 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8952
Documented Hormone Replacement Therapy Use and Subsequent Rotator Cuff Tear Diagnoses and Repair Procedures: A Propensity Score-Matched Cohort Study
Background: The association between hormone replacement therapy (HRT) use and rotator cuff outcomes remains uncertain. This study evaluated the association of baseline HRT documentation with subsequently recorded rotator cuff tear diagnoses and repair surgery in women with menopausal diagnoses. Methods: Using the TriNetX global federated health research database, we identified women aged ≥50 years at a qualifying menopausal or climacteric diagnosis recorded between January 2010 and December 2022. HRT exposure was classified according to the presence or absence of ICD-10-CM Z79.890 on or before the index date. Patients with prior rotator cuff tear or repair were excluded before 1:1 propensity-score matching. Matching included age, cardiometabolic comorbidities, osteoporosis, systemic corticosteroid use, tobacco use/nicotine dependence, systemic inflammatory disorders, and postprocedural ovarian failure. Outcomes recorded were rotator cuff tear diagnoses and repair procedures over 3 years. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated using Cox proportional hazards models. Sensitivity analyses examined an alternative propensity-score specification and a medication-corroborated exposure definition. E-values quantified sensitivity to unmeasured confounding. Results: The primary matched analysis included 27,918 women per group. Mean age was 59.2 years in both groups, and all displayed baseline characteristics had standardized mean differences <0.1. Mean follow-up was 1035 days in the HRT group and 1028 days in the comparator group. Observed event proportions were 2.28% versus 1.90% for rotator cuff tear diagnoses (636 versus 531 events; HR, 1.192; 95% CI, 1.063–1.338) and 0.35% versus 0.20% for repair procedures (97 versus 57 events; HR, 1.691; 95% CI, 1.219–2.345). Sensitivity analyses showed directionally consistent associations. E-values for the point estimate and lower confidence limit were 1.67 and 1.32 for tear diagnoses and 2.77 and 1.74 for repair procedures. Conclusions: Baseline HRT documentation was associated with subsequently recorded rotator cuff tear diagnoses and repair procedures. Residual confounding by pretreatment hormonal status and treatment indications remains possible. These findings do not establish causality or support changing HRT initiation, continuation, or discontinuation on the basis of rotator cuff risk.
- 15 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8952
Open AccessDocumented Hormone Replacement Therapy Use and Subsequent Rotator Cuff Tear Diagnoses and Repair Procedures: A Propensity Score-Matched Cohort Study
Background: The association between hormone replacement therapy (HRT) use and rotator cuff outcomes remains uncertain. This study evaluated the association of baseline HRT documentation with subsequently recorded rotator cuff tear diagnoses and repair surgery in women with menopausal diagnoses. Methods: Using the TriNetX global federated health research database, we identified women aged ≥50 years at a qualifying menopausal or climacteric diagnosis recorded between January 2010 and December 2022. HRT exposure was classified according to the presence or absence of ICD-10-CM Z79.890 on or before the index date. Patients with prior rotator cuff tear or repair were excluded before 1:1 propensity-score matching. Matching included age, cardiometabolic comorbidities, osteoporosis, systemic corticosteroid use, tobacco use/nicotine dependence, systemic inflammatory disorders, and postprocedural ovarian failure. Outcomes recorded were rotator cuff tear diagnoses and repair procedures over 3 years. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated using Cox proportional hazards models. Sensitivity analyses examined an alternative propensity-score specification and a medication-corroborated exposure definition. E-values quantified sensitivity to unmeasured confounding. Results: The primary matched analysis included 27,918 women per group. Mean age was 59.2 years in both groups, and all displayed baseline characteristics had standardized mean differences <0.1. Mean follow-up was 1035 days in the HRT group and 1028 days in the comparator group. Observed event proportions were 2.28% versus 1.90% for rotator cuff tear diagnoses (636 versus 531 events; HR, 1.192; 95% CI, 1.063–1.338) and 0.35% versus 0.20% for repair procedures (97 versus 57 events; HR, 1.691; 95% CI, 1.219–2.345). Sensitivity analyses showed directionally consistent associations. E-values for the point estimate and lower confidence limit were 1.67 and 1.32 for tear diagnoses and 2.77 and 1.74 for repair procedures. Conclusions: Baseline HRT documentation was associated with subsequently recorded rotator cuff tear diagnoses and repair procedures. Residual confounding by pretreatment hormonal status and treatment indications remains possible. These findings do not establish causality or support changing HRT initiation, continuation, or discontinuation on the basis of rotator cuff risk.
- 5 November 2026
- Published by Elsevier in Diabetes & Metabolism
- Vol. 52 (6)
Risk of incident type 2 diabetes with romosozumab versus denosumab in patients with osteoporosis: A global real-world cohort study
- 5 November 2026
- Published by Elsevier in Diabetes & Metabolism
- Vol. 52 (6)
Risk of incident type 2 diabetes with romosozumab versus denosumab in patients with osteoporosis: A global real-world cohort study
- Open Access
- 4 September 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (36) , e50545
Reconstruction of a 2‑year neglected chronic patellar tendon rupture using peroneus longus autograft with suture anchor and cerclage wire augmentation
Rationale: Chronic patellar tendon rupture with complete tendon loss is difficult to reconstruct when primary repair is impossible. We report reconstruction using an ipsilateral peroneus longus (PL) autograft in a 4-strand “M-shaped” configuration with suture-anchor fixation and temporary cerclage augmentation. Patient concerns: A 17-year-old male had progressive anterior knee pain, instability, and inability to actively extend the left knee for 2 years after trauma. Diagnoses: Examination showed patella alta, a palpable infrapatellar gap, and complete loss of active extension. Radiographs showed an Insall–Salvati ratio of 1.28. Magnetic resonance imaging confirmed chronic complete patellar tendon rupture without a repairable stump. Interventions: A 21-cm ipsilateral PL autograft was folded into a 4-strand construct and anchored to the inferior patella and tibial tubercle. Patellar height was deliberately overcorrected, and a transpatellar–tibial cerclage wire protected the reconstruction during staged rehabilitation. Outcomes: At 1 year, after wire removal, the Insall–Salvati ratio was 1.08. The patient regained full active extension without lag, near-full flexion, and recreational activity participation without pain or donor-site morbidity. Asymptomatic wire breakage occurred at 6 months. Lessons: A multi-strand PL autograft with anchor fixation and temporary cerclage augmentation may restore patellar height and extensor function in chronic patellar tendon rupture with complete tendon loss.
- 4 September 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (36) , e50545
Open AccessReconstruction of a 2‑year neglected chronic patellar tendon rupture using peroneus longus autograft with suture anchor and cerclage wire augmentation
Rationale: Chronic patellar tendon rupture with complete tendon loss is difficult to reconstruct when primary repair is impossible. We report reconstruction using an ipsilateral peroneus longus (PL) autograft in a 4-strand “M-shaped” configuration with suture-anchor fixation and temporary cerclage augmentation. Patient concerns: A 17-year-old male had progressive anterior knee pain, instability, and inability to actively extend the left knee for 2 years after trauma. Diagnoses: Examination showed patella alta, a palpable infrapatellar gap, and complete loss of active extension. Radiographs showed an Insall–Salvati ratio of 1.28. Magnetic resonance imaging confirmed chronic complete patellar tendon rupture without a repairable stump. Interventions: A 21-cm ipsilateral PL autograft was folded into a 4-strand construct and anchored to the inferior patella and tibial tubercle. Patellar height was deliberately overcorrected, and a transpatellar–tibial cerclage wire protected the reconstruction during staged rehabilitation. Outcomes: At 1 year, after wire removal, the Insall–Salvati ratio was 1.08. The patient regained full active extension without lag, near-full flexion, and recreational activity participation without pain or donor-site morbidity. Asymptomatic wire breakage occurred at 6 months. Lessons: A multi-strand PL autograft with anchor fixation and temporary cerclage augmentation may restore patellar height and extensor function in chronic patellar tendon rupture with complete tendon loss.
- Open Access
- 1 January 2026
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 34 (1)
Hook plate fixation for distal clavicle and acromioclavicular joint injuries: Insights into peri-implant fracture risk
Background: Distal clavicle fractures and acromioclavicular joint dislocations frequently require surgical stabilization, and hook plate fixation is widely used but can be complicated by peri-implant fractures. This study aimed to evaluate patient, anatomical, and implant-related factors associated with peri-implant fractures after hook plate fixation for these injuries. Methods: A retrospective cohort study was conducted at a single tertiary center including adults who underwent open reduction and internal fixation with a pre-contoured clavicle hook plate for distal clavicle fractures or acromioclavicular joint dislocations between October 2013 and November 2023. Demographic data, implant characteristics, and radiographic parameters (clavicle diameter, clavicle length, plate diameter, plate length, and their ratios) were collected. Patients with and without peri-implant fracture were compared using univariable statistical tests, and exploratory univariable logistic regression was performed to estimate associations between selected variables and peri-implant fracture. Results: Among 282 patients, 9 (3%) developed peri-implant fractures after hook plate fixation. Patients with peri-implant fractures were older, shorter, and had lower body weight than those without fractures. The peri-implant fracture group also showed a smaller clavicle-to-plate diameter ratio, a higher plate-to-clavicle length ratio, and more frequent use of plates with a greater number of holes, indicating relatively thinner clavicles and disproportionately longer plates. Conclusions: Peri-implant fractures after hook plate fixation for distal clavicle fractures and acromioclavicular joint dislocations were uncommon in this cohort but were associated with older age, smaller skeletal build, longer plates, and poor dimensional matching between the clavicle and plate. Careful assessment of clavicle morphology and judicious selection of plate length may help reduce stress concentration at the medial plate end and lower the risk of peri-implant fracture.
- 1 January 2026
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 34 (1)
Open AccessHook plate fixation for distal clavicle and acromioclavicular joint injuries: Insights into peri-implant fracture risk
Background: Distal clavicle fractures and acromioclavicular joint dislocations frequently require surgical stabilization, and hook plate fixation is widely used but can be complicated by peri-implant fractures. This study aimed to evaluate patient, anatomical, and implant-related factors associated with peri-implant fractures after hook plate fixation for these injuries. Methods: A retrospective cohort study was conducted at a single tertiary center including adults who underwent open reduction and internal fixation with a pre-contoured clavicle hook plate for distal clavicle fractures or acromioclavicular joint dislocations between October 2013 and November 2023. Demographic data, implant characteristics, and radiographic parameters (clavicle diameter, clavicle length, plate diameter, plate length, and their ratios) were collected. Patients with and without peri-implant fracture were compared using univariable statistical tests, and exploratory univariable logistic regression was performed to estimate associations between selected variables and peri-implant fracture. Results: Among 282 patients, 9 (3%) developed peri-implant fractures after hook plate fixation. Patients with peri-implant fractures were older, shorter, and had lower body weight than those without fractures. The peri-implant fracture group also showed a smaller clavicle-to-plate diameter ratio, a higher plate-to-clavicle length ratio, and more frequent use of plates with a greater number of holes, indicating relatively thinner clavicles and disproportionately longer plates. Conclusions: Peri-implant fractures after hook plate fixation for distal clavicle fractures and acromioclavicular joint dislocations were uncommon in this cohort but were associated with older age, smaller skeletal build, longer plates, and poor dimensional matching between the clavicle and plate. Careful assessment of clavicle morphology and judicious selection of plate length may help reduce stress concentration at the medial plate end and lower the risk of peri-implant fracture.
- Open Access
- 9 March 2025
- Published by Elsevier in Asian Journal of Surgery
- Vol. 48 (5) , 2897-2901
Long-term survival outcome of patients with femoral neck and trochanteric fractures: A nationwide population-based observational study
- 9 March 2025
- Published by Elsevier in Asian Journal of Surgery
- Vol. 48 (5) , 2897-2901
Open AccessLong-term survival outcome of patients with femoral neck and trochanteric fractures: A nationwide population-based observational study
- 23 March 2023
- Published by Wiley in Anatomical Sciences Education
- Vol. 16 (5) , 858-869
Effects of the individual three‐dimensional printed craniofacial bones with a quick response code on the skull spatial knowledge of undergraduate medical students
Understanding the three‐dimensional (3D) structure of the human skull is imperative for medical courses. However, medical students are overwhelmed by the spatial complexity of the skull. Separated polyvinyl chloride (PVC) bone models have advantages as learning tools, but they are fragile and expensive. This study aimed to reconstruct 3D‐printed skull bone models (3D‐PSBs) using polylactic acid (PLA) with anatomical characteristics for spatial recognition of the skull. Student responses to 3D‐PSB application were investigated through a questionnaire and tests to understand the requirement of these models as a learning tool. The students were randomly divided into 3D‐PSB (n = 63) and skull (n = 67) groups to analyze pre‐ and post‐test scores. Their knowledge was improved, with the gain scores of the 3D‐PSB group (50.0 ± 3.0) higher than that of the skull group (37.3 ± 5.2). Most students agreed that using 3D‐PSBs with quick response codes could improve immediate feedback on teaching (88%; 4.41 ± 0.75), while 85.9% of the students agreed that individual 3D‐PSBs clarified the structures hidden within the skull (4.41 ± 0.75). The ball drop test revealed that the mechanical strength of the cement/PLA model was significantly greater than that of the cement or PLA model. The prices of the PVC, cement, and cement/PLA models were 234, 1.9, and 10 times higher than that of the 3D‐PSB model, respectively. These findings imply that low‐cost 3D‐PSB models could revolutionize skull anatomical education by incorporating digital technologies like the QR system into the anatomical teaching repertoire.
- 23 March 2023
- Published by Wiley in Anatomical Sciences Education
- Vol. 16 (5) , 858-869
Effects of the individual three‐dimensional printed craniofacial bones with a quick response code on the skull spatial knowledge of undergraduate medical students
Understanding the three‐dimensional (3D) structure of the human skull is imperative for medical courses. However, medical students are overwhelmed by the spatial complexity of the skull. Separated polyvinyl chloride (PVC) bone models have advantages as learning tools, but they are fragile and expensive. This study aimed to reconstruct 3D‐printed skull bone models (3D‐PSBs) using polylactic acid (PLA) with anatomical characteristics for spatial recognition of the skull. Student responses to 3D‐PSB application were investigated through a questionnaire and tests to understand the requirement of these models as a learning tool. The students were randomly divided into 3D‐PSB (n = 63) and skull (n = 67) groups to analyze pre‐ and post‐test scores. Their knowledge was improved, with the gain scores of the 3D‐PSB group (50.0 ± 3.0) higher than that of the skull group (37.3 ± 5.2). Most students agreed that using 3D‐PSBs with quick response codes could improve immediate feedback on teaching (88%; 4.41 ± 0.75), while 85.9% of the students agreed that individual 3D‐PSBs clarified the structures hidden within the skull (4.41 ± 0.75). The ball drop test revealed that the mechanical strength of the cement/PLA model was significantly greater than that of the cement or PLA model. The prices of the PVC, cement, and cement/PLA models were 234, 1.9, and 10 times higher than that of the 3D‐PSB model, respectively. These findings imply that low‐cost 3D‐PSB models could revolutionize skull anatomical education by incorporating digital technologies like the QR system into the anatomical teaching repertoire.