Tommaso Lorenzon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tommaso Lorenzon has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Davide Bozzato
CERN, Geneva, GE, SWITZERLAND
9 shared publications - Robert Froeschl
CERN
8 shared publications - Angelo Infantino
European Organization for Nuclear Research (CERN)
4 shared publications - Fabio Pozzi
CERN, 1211 Geneva 23, Switzerland
4 shared publications - Stefan Roesler
CERN
4 shared publications - Arnaud Devienne
European Organization for Nuclear Research
3 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by Elsevier in Radiation Measurements
- Vol. 200
Comparison of residual ambient dose equivalent rate FLUKA predictions for common accelerator materials at the CHARM facility at CERN
- 18 November 2026
- Published by Elsevier in Radiation Measurements
- Vol. 200
Open AccessComparison of residual ambient dose equivalent rate FLUKA predictions for common accelerator materials at the CHARM facility at CERN
- Open Access
- 8 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Measurements and FLUKA Monte Carlo simulations of steel, aluminium, and copper activation at the CMS experiment at the Large Hadron Collider at CERN
- 8 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Open AccessMeasurements and FLUKA Monte Carlo simulations of steel, aluminium, and copper activation at the CMS experiment at the Large Hadron Collider at CERN
- Open Access
- 15 July 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 231
Benchmarking of the FLUKA Monte Carlo code against the SINBAD FNG dose experiment for shutdown dose rates in D–T fusion applications
- 15 July 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 231
Open AccessBenchmarking of the FLUKA Monte Carlo code against the SINBAD FNG dose experiment for shutdown dose rates in D–T fusion applications
- Open Access
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Benchmarking of the FLUKA Monte Carlo code against the SINBAD FNG dose experiment for Shutdown Dose Rates in D-T Fusion Applications
The assessment of shutdown dose rates in fusion facilities is crucial for ensuring safe operation, particularly for worker access to critical areas. Accurate prediction of radiation levels is therefore essential, but technically challenging. The FNG dose benchmark, included in the SINBAD database, is a well-known experiment widely used to validate novel workflows for residual dose rate assessments. In this work, the FNG dose benchmark was implemented for use with the FLUKA Monte Carlo code (version 4-5.0) and quantitatively compared with the available experimental data. FLUKA built-in options enabled one-step simulations that automatically accounted for the time evolution of the full radionuclide inventory, using the internal database to eventually evaluate dose rates at shutdown. Furthermore, examples were provided to illustrate the code’s ability to generate informative outputs. The implementation also involved replicating the literature FNG source routine in FLUKA, with potential applicability to other SINBAD FNG cases. Comparison to literature and the agreement of results with experimental data was generally within a factor of two, demonstrating the reliability and flexibility of the code for reproducing complex fusion benchmarks.
- 4 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBenchmarking of the FLUKA Monte Carlo code against the SINBAD FNG dose experiment for Shutdown Dose Rates in D-T Fusion Applications
The assessment of shutdown dose rates in fusion facilities is crucial for ensuring safe operation, particularly for worker access to critical areas. Accurate prediction of radiation levels is therefore essential, but technically challenging. The FNG dose benchmark, included in the SINBAD database, is a well-known experiment widely used to validate novel workflows for residual dose rate assessments. In this work, the FNG dose benchmark was implemented for use with the FLUKA Monte Carlo code (version 4-5.0) and quantitatively compared with the available experimental data. FLUKA built-in options enabled one-step simulations that automatically accounted for the time evolution of the full radionuclide inventory, using the internal database to eventually evaluate dose rates at shutdown. Furthermore, examples were provided to illustrate the code’s ability to generate informative outputs. The implementation also involved replicating the literature FNG source routine in FLUKA, with potential applicability to other SINBAD FNG cases. Comparison to literature and the agreement of results with experimental data was generally within a factor of two, demonstrating the reliability and flexibility of the code for reproducing complex fusion benchmarks.
- Open Access
- 14 May 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 236
Measurement and Monte Carlo simulation of steel and copper activation at the CHARM and CSBF facilities at CERN
- 14 May 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 236
Open AccessMeasurement and Monte Carlo simulation of steel and copper activation at the CHARM and CSBF facilities at CERN
- 3 December 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 201 (1) , 41-47
Monte Carlo implementation of a Gaussian plume model for submersion dose calculation at short downwind distances
In this article, the submersion dose due to a radioactive cloud of pollutants was evaluated at short downwind distances from an emission stack. The atmospheric transport of contaminants was modelled using the Gaussian plume model (GPM). The algorithm for dose computation and its hypotheses were analysed. Two relevant issues were discussed: the semi-infinite cloud approximation used for pre-calculated dose conversion factors and the lack of a radiation transport model for dose computation outside the radioactive cloud. The GPM-based software HotSpot and GENII V2.10 and a FLUKA Monte Carlo GPM implementation were compared in a scenario characterized by a low release height and two different simplified atmospheric conditions. Compared to FLUKA, HotSpot and GENII V2.10 results showed a significant dose overestimation inside the plume. Moreover, in extremely stable meteorological conditions, only the Monte Carlo code could detect the ground-level dose contribution from an overhead plume.
- 3 December 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 201 (1) , 41-47
Monte Carlo implementation of a Gaussian plume model for submersion dose calculation at short downwind distances
In this article, the submersion dose due to a radioactive cloud of pollutants was evaluated at short downwind distances from an emission stack. The atmospheric transport of contaminants was modelled using the Gaussian plume model (GPM). The algorithm for dose computation and its hypotheses were analysed. Two relevant issues were discussed: the semi-infinite cloud approximation used for pre-calculated dose conversion factors and the lack of a radiation transport model for dose computation outside the radioactive cloud. The GPM-based software HotSpot and GENII V2.10 and a FLUKA Monte Carlo GPM implementation were compared in a scenario characterized by a low release height and two different simplified atmospheric conditions. Compared to FLUKA, HotSpot and GENII V2.10 results showed a significant dose overestimation inside the plume. Moreover, in extremely stable meteorological conditions, only the Monte Carlo code could detect the ground-level dose contribution from an overhead plume.
- Open Access
- 2 December 2024
- Published by EDP Sciences in EPJ Nuclear Sciences & Technologies
- Vol. 10, 20
Latest FLUKA developments
The FLUKA Monte Carlo code has recently undergone significant enhancements, driven by needs from its user community. Key improvements are discussed, such as a new point-wise treatment for the interactions of low-energy neutrons, the incorporation of a new model for nuclear elastic scattering of protons below 250 MeV, explicit generation of synchrotron radiation photons during charged particle tracking, a revised modeling approach for coherent effects in bent crystals, and the addition of arc-DPA scoring. While improving and extending FLUKA physics performance is essential, it is equally important to ensure the long-term maintainability of the codebase. This paper also outlines the strategy and substantial progress in evolving FLUKA to meet this objective. The FLUKA features are being translated into a new codebase, fulfilling essential criteria such as continuity in the user experience and compatibility with existing inputs, thus laying the foundation for a new FLUKA generation. The codebase makes use of the Geant4 toolkit when appropriate. Additionally, the enhanced collaboration with Geant4 has resulted in the development of an interface, detailed in this paper, that enables access to the FLUKA hadronic models from any Geant4 application.
- 2 December 2024
- Published by EDP Sciences in EPJ Nuclear Sciences & Technologies
- Vol. 10, 20
Open AccessLatest FLUKA developments
The FLUKA Monte Carlo code has recently undergone significant enhancements, driven by needs from its user community. Key improvements are discussed, such as a new point-wise treatment for the interactions of low-energy neutrons, the incorporation of a new model for nuclear elastic scattering of protons below 250 MeV, explicit generation of synchrotron radiation photons during charged particle tracking, a revised modeling approach for coherent effects in bent crystals, and the addition of arc-DPA scoring. While improving and extending FLUKA physics performance is essential, it is equally important to ensure the long-term maintainability of the codebase. This paper also outlines the strategy and substantial progress in evolving FLUKA to meet this objective. The FLUKA features are being translated into a new codebase, fulfilling essential criteria such as continuity in the user experience and compatibility with existing inputs, thus laying the foundation for a new FLUKA generation. The codebase makes use of the Geant4 toolkit when appropriate. Additionally, the enhanced collaboration with Geant4 has resulted in the development of an interface, detailed in this paper, that enables access to the FLUKA hadronic models from any Geant4 application.
- Open Access
- 4 November 2024
- Published by F1000 Research Ltd in Nuclear Science and Technology Open Research
- Vol. 2, 71
Advanced Monte Carlo simulations and benchmark of residual dose rate assessments in the ATLAS detector at CERN LHC
Background The European Organization for Nuclear Research (CERN) pushes the frontiers of physics through the Large Hadron Collider (LHC), a 27-kilometre hadron accelerator capable of producing proton-proton collisions at a center-of-mass energy of up to 13.6 TeV. Its four main detectors (ALICE, ATLAS, CMS, LHCb) are unique examples of advanced particle detection technology and complexity. Ensuring radiological safety throughout the LHC’s environments and lifecycle is a critical task managed by the CERN Radiation Protection group. In this context, assessing residual dose rates is crucial for planning exposure situations, such as maintenance and upgrade projects during LHC shutdowns. Methods This work presents advanced Monte Carlo techniques developed at CERN to predict residual dose rates in the LHC experimental caverns, focusing on the ATLAS detector. Predictions are made using the FLUKA Monte Carlo code and the SESAME toolkit for two-step simulations. The simulation results are benchmarked against experimental residual dose rate measurements collected during LHC Long Shutdown 2 at ATLAS. Additionally, forecasts for Long Shutdown 3 are also presented. Results The FLUKA benchmark for the ATLAS detector demonstrates a general agreement within a factor of 1.5. This consistency validates both the FLUKA geometry model of the ATLAS detector and the reliability of the Monte Carlo techniques used to predict residual dose rates in such complex environments. Conclusions The study highlights the predictive capabilities of the FLUKA and SESAME coupling for simulating residual dose rates in large LHC experiments. This method plays a crucial role in ensuring radiological safety, primarily for dose prediction and optimization. The reliability of this approach is significantly supported by the benchmark results obtained at ATLAS and presented in this paper.
- 4 November 2024
- Published by F1000 Research Ltd in Nuclear Science and Technology Open Research
- Vol. 2, 71
Open AccessAdvanced Monte Carlo simulations and benchmark of residual dose rate assessments in the ATLAS detector at CERN LHC
Background The European Organization for Nuclear Research (CERN) pushes the frontiers of physics through the Large Hadron Collider (LHC), a 27-kilometre hadron accelerator capable of producing proton-proton collisions at a center-of-mass energy of up to 13.6 TeV. Its four main detectors (ALICE, ATLAS, CMS, LHCb) are unique examples of advanced particle detection technology and complexity. Ensuring radiological safety throughout the LHC’s environments and lifecycle is a critical task managed by the CERN Radiation Protection group. In this context, assessing residual dose rates is crucial for planning exposure situations, such as maintenance and upgrade projects during LHC shutdowns. Methods This work presents advanced Monte Carlo techniques developed at CERN to predict residual dose rates in the LHC experimental caverns, focusing on the ATLAS detector. Predictions are made using the FLUKA Monte Carlo code and the SESAME toolkit for two-step simulations. The simulation results are benchmarked against experimental residual dose rate measurements collected during LHC Long Shutdown 2 at ATLAS. Additionally, forecasts for Long Shutdown 3 are also presented. Results The FLUKA benchmark for the ATLAS detector demonstrates a general agreement within a factor of 1.5. This consistency validates both the FLUKA geometry model of the ATLAS detector and the reliability of the Monte Carlo techniques used to predict residual dose rates in such complex environments. Conclusions The study highlights the predictive capabilities of the FLUKA and SESAME coupling for simulating residual dose rates in large LHC experiments. This method plays a crucial role in ensuring radiological safety, primarily for dose prediction and optimization. The reliability of this approach is significantly supported by the benchmark results obtained at ATLAS and presented in this paper.
- Open Access
- 27 June 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1066
Monte Carlo intercomparison and benchmark of the neutron streaming in the ramified access maze of the CERN High-energy AcceleRator Mixed field (CHARM) facility at CERN
- 27 June 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1066
Open AccessMonte Carlo intercomparison and benchmark of the neutron streaming in the ramified access maze of the CERN High-energy AcceleRator Mixed field (CHARM) facility at CERN
- Open Access
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (2) , 205-212
Multiequipment Radiation Measurements in a Field Generated by Bombarding a 1-GeV/u Fe Beam on a Polyethylene Target at GSI and Comparison to FLUKA Simulations
The complex nature of the radiation environment in various high-energy physics facilities necessitates the use of different kinds of radiation monitors. The detectors used could be either passive or active and need dedicated read out electronics. The present study was conducted at GSI Helmholtzzentrum für Schwerionenforschung in Cave A where different kinds of radiation detectors were tested in parallel in the secondary radiation field generated by a 1 GeV/u 56 Fe ion beam impinging a thick polyethylene target, and their responses were compared to Monte Carlo code FLUKA simulations. Thermoluminescence-based passive detectors from GSI, ionization chamber-based radiation monitors developed by CERN, WENDI-II, and wide-range photon detectors from Berthold and Thermo Fisher were studied in this campaign. The study showed good agreement between the temporal responses of the various detectors, and comparison of the ambient dose equivalents measured with the simulations showed agreement of over 40% for all the detectors. Additionally, two versions of radiation monitoring front-ends developed at CERN were directly compared and the relative mismatch in measurement was consistently less than 10%.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (2) , 205-212
Open AccessMultiequipment Radiation Measurements in a Field Generated by Bombarding a 1-GeV/u Fe Beam on a Polyethylene Target at GSI and Comparison to FLUKA Simulations
The complex nature of the radiation environment in various high-energy physics facilities necessitates the use of different kinds of radiation monitors. The detectors used could be either passive or active and need dedicated read out electronics. The present study was conducted at GSI Helmholtzzentrum für Schwerionenforschung in Cave A where different kinds of radiation detectors were tested in parallel in the secondary radiation field generated by a 1 GeV/u 56 Fe ion beam impinging a thick polyethylene target, and their responses were compared to Monte Carlo code FLUKA simulations. Thermoluminescence-based passive detectors from GSI, ionization chamber-based radiation monitors developed by CERN, WENDI-II, and wide-range photon detectors from Berthold and Thermo Fisher were studied in this campaign. The study showed good agreement between the temporal responses of the various detectors, and comparison of the ambient dose equivalents measured with the simulations showed agreement of over 40% for all the detectors. Additionally, two versions of radiation monitoring front-ends developed at CERN were directly compared and the relative mismatch in measurement was consistently less than 10%.