Dona N. Sangapalaarachchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dona N. Sangapalaarachchi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Daichi Shimbo
Columbia University Irving Medical Center
2 shared publications - Eung Ho Choi
Department of Dermatology, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
2 shared publications - Hiroyuki Mizuno
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan (K.K., K.H., Y.I., T.F., K.N., Y.S., H.M., N.T., S.H.).
2 shared publications - Joseph Schwartz
Columbia University Irving Medical Center
2 shared publications Justin Liu
The Columbia Hypertension Center and Lab Columbia University Irving Medical Center New York NY
2 shared publications- Kazuomi Kario
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan
2 shared publications
Latest Publications
- Open Access
- 19 December 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (24) , e030150
Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study
Background: Using high awake blood pressure (BP; ≥130/80 mm Hg) on ambulatory BP monitoring (ABPM) as a reference, the purpose of this study was to determine the accuracy of high office BP (≥130/80 mm Hg) at an initial visit and high confirmatory office BP (≥130/80 mm Hg), and separately, high home BP (≥130/80 mm Hg) among participants with high office BP (≥130/80 mm Hg) at an initial office visit. Methods and Results: The accuracy of office BP measurements using the oscillometric method for detecting high BP on ABPM was determined among 379 participants with complete office BP and ABPM data in the IDH (Improving the Detection of Hypertension) study. For detecting high BP on ABPM, the accuracy of high confirmatory office BP using the oscillometric method and, separately, high home BP was also determined among the subgroup of 122 participants with high office BP at an initial visit and complete home BP monitoring data. High office BP had moderate sensitivity (0.61 [95% CI, 0.53–0.68]) and high specificity (0.85 [95% CI, 0.80–0.90]) for high awake BP. High confirmatory office BP and high home BP had moderate sensitivity (0.69 [95% CI, 0.59–0.79] and 0.79 [95% CI, 0.71–0.87], respectively) and low and moderate specificity (0.44 [95% CI, 0.27–0.61] and 0.72 [95% CI, 0.56–0.88], respectively). Conclusions: Many individuals with high BP on ABPM do not have high office BP. Confirmatory office BP and home blood pressure monitoring also had limited ability to identify individuals with high BP on ABPM.
- 19 December 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (24) , e030150
Open AccessDiagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study
Background: Using high awake blood pressure (BP; ≥130/80 mm Hg) on ambulatory BP monitoring (ABPM) as a reference, the purpose of this study was to determine the accuracy of high office BP (≥130/80 mm Hg) at an initial visit and high confirmatory office BP (≥130/80 mm Hg), and separately, high home BP (≥130/80 mm Hg) among participants with high office BP (≥130/80 mm Hg) at an initial office visit. Methods and Results: The accuracy of office BP measurements using the oscillometric method for detecting high BP on ABPM was determined among 379 participants with complete office BP and ABPM data in the IDH (Improving the Detection of Hypertension) study. For detecting high BP on ABPM, the accuracy of high confirmatory office BP using the oscillometric method and, separately, high home BP was also determined among the subgroup of 122 participants with high office BP at an initial visit and complete home BP monitoring data. High office BP had moderate sensitivity (0.61 [95% CI, 0.53–0.68]) and high specificity (0.85 [95% CI, 0.80–0.90]) for high awake BP. High confirmatory office BP and high home BP had moderate sensitivity (0.69 [95% CI, 0.59–0.79] and 0.79 [95% CI, 0.71–0.87], respectively) and low and moderate specificity (0.44 [95% CI, 0.27–0.61] and 0.72 [95% CI, 0.56–0.88], respectively). Conclusions: Many individuals with high BP on ABPM do not have high office BP. Confirmatory office BP and home blood pressure monitoring also had limited ability to identify individuals with high BP on ABPM.
- 1 October 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (10) , 2169-2177
Use of Different Blood Pressure Thresholds to Reduce the Number of Home Blood Pressure Monitoring Days Needed for Detecting Hypertension
BACKGROUND: Home blood pressure (BP) monitoring over a 7-day period is recommended to confirm the diagnosis of hypertension. METHODS: We determined upper and lower home BP thresholds with >90% positive predictive value and >90% negative predictive value using 1 to 6 days of monitoring to identify high home BP (systolic BP ≥130 mm Hg or diastolic BP ≥80 mm Hg) based on 7 days of home BP monitoring. The sample included 361 adults from the Improving the Detection of Hypertension Study who were not taking antihypertensive medication. We used two 7-day periods, at least 3 days apart, the first being a sampling period and the second a reference period. For each number of days in the sampling period, we determined the percentage of participants who had a high likelihood of having (>90% positive predictive value) or not having (>90% negative predictive value) high BP and would not need to continue home BP monitoring. Only the participants in an uncertain category (ie, positive predictive value ≤90% and negative predictive value ≤90%) after each day were carried forward to the next day of home BP monitoring. RESULTS: Of the 361 participants (mean [SD] age of 41.3 [13.2] years; 60.4% women), 38.0% had high home BP during the reference period. There were 63.7%, 17.1%, 10.5%, 3.3%, 3.6%, and 1.4% participants who would not need to continue after 1, 2, 3, 4, 5, and 6 days of monitoring. CONCLUSIONS: In most people, high home BP can be identified or excluded with a high degree of confidence with 3 days or less of monitoring.
- 1 October 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (10) , 2169-2177
Use of Different Blood Pressure Thresholds to Reduce the Number of Home Blood Pressure Monitoring Days Needed for Detecting Hypertension
BACKGROUND: Home blood pressure (BP) monitoring over a 7-day period is recommended to confirm the diagnosis of hypertension. METHODS: We determined upper and lower home BP thresholds with >90% positive predictive value and >90% negative predictive value using 1 to 6 days of monitoring to identify high home BP (systolic BP ≥130 mm Hg or diastolic BP ≥80 mm Hg) based on 7 days of home BP monitoring. The sample included 361 adults from the Improving the Detection of Hypertension Study who were not taking antihypertensive medication. We used two 7-day periods, at least 3 days apart, the first being a sampling period and the second a reference period. For each number of days in the sampling period, we determined the percentage of participants who had a high likelihood of having (>90% positive predictive value) or not having (>90% negative predictive value) high BP and would not need to continue home BP monitoring. Only the participants in an uncertain category (ie, positive predictive value ≤90% and negative predictive value ≤90%) after each day were carried forward to the next day of home BP monitoring. RESULTS: Of the 361 participants (mean [SD] age of 41.3 [13.2] years; 60.4% women), 38.0% had high home BP during the reference period. There were 63.7%, 17.1%, 10.5%, 3.3%, 3.6%, and 1.4% participants who would not need to continue after 1, 2, 3, 4, 5, and 6 days of monitoring. CONCLUSIONS: In most people, high home BP can be identified or excluded with a high degree of confidence with 3 days or less of monitoring.