CKChadaporn Keatmanee

Chadaporn Keatmanee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chadaporn Keatmanee has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Combining curriculum learning and weakly supervised attention for enhanced thyroid nodule assessment in ultrasound imaging

    by Chadaporn Keatmanee, Dittapong Songsaeng, Songphon Klabwong, Yoichi Nakaguro, Alisa Kunapinun, Mongkol Ekpanyapong, Matthew N. Dailey

    Background: The accurate assessment of thyroid nodules, which are increasingly common with age and lifestyle factors, is essential for early malignancy detection. Ultrasound imaging, the primary diagnostic tool for this purpose, holds promise when paired with deep learning. However, challenges persist with small datasets, where conventional data augmentation can introduce noise and obscure essential diagnostic features. To address dataset imbalance and enhance model generalization, this study integrates curriculum learning with a weakly supervised attention network to improve diagnostic accuracy for thyroid nodule classification. Methods: This study integrates curriculum learning with attention-guided data augmentation to improve deep learning model performance in classifying thyroid nodules. Using verified datasets from Siriraj Hospital, the model was trained progressively, beginning with simpler images and gradually incorporating more complex cases. This structured learning approach is designed to enhance the model’s diagnostic accuracy by refining its ability to distinguish benign from malignant nodules. Results: Among the curriculum learning schemes tested, schematic IV achieved the best results, with a precision of 100% for benign and 70% for malignant nodules, a recall of 82% for benign and 100% for malignant, and F1-scores of 90% and 83%, respectively. This structured approach improved the model’s diagnostic sensitivity and robustness. Conclusions: These findings suggest that automated thyroid nodule assessment, supported by curriculum learning, has the potential to complement radiologists in clinical practice, enhancing diagnostic accuracy and aiding in more reliable malignancy detection.

  • Enhancing weakly supervised data augmentation networks for thyroid nodule assessment using traditional and doppler ultrasound images

    by Chadaporn Keatmanee, Dittapong Songsaeng, Songphon Klabwong, Yoichi Nakaguro, Alisa Kunapinun, Mongkol Ekpanyapong, Matthew N. Dailey


  • Curriculum Learning for Assessing Thyroid Nodules Using Imbalanced Ultrasound Images

    by Chadaporn Keatmanee, Sophonwish Thongsreejun, Sathit Nakkrasae, Atchara Mahaweerawat, Chatree Nilnumpetch, Songphon Klabwong, Yoichi Nakaguro

  • Open Access

    Diagnostic performance of artificial intelligence in interpreting thyroid nodules on ultrasound images: a multicenter retrospective study

    by Pawitchaya Namsena, Dittapong Songsaeng, Chadaporn Keatmanee, Songphon Klabwong, Alisa Kunapinun, Sunsiree Soodchuen, Thipthara Tarathipayakul, Wasu Tanasoontrarat, Mongkol Ekpanyapong, Matthew N. Dailey

    Background: Thyroid nodules are commonly identified through ultrasound imaging, which plays a crucial role in the early detection of malignancy. The diagnostic accuracy, however, is significantly influenced by the expertise of radiologists, the quality of equipment, and image acquisition techniques. This variability underscores the critical need for computational tools that support diagnosis. Methods: This retrospective study evaluates an artificial intelligence (AI)-driven system for thyroid nodule assessment, integrating clinical practices from multiple prominent Thai medical centers. We included patients who underwent thyroid ultrasonography complemented by ultrasound-guided fine needle aspiration (FNA) between January 2015 and March 2021. Participants formed a consecutive series, enhancing the study’s validity. A comparative analysis was conducted between the AI model’s diagnostic performance and that of both an experienced radiologist and a third-year radiology resident, using a dataset of 600 ultrasound images from three distinguished Thai medical institutions, each verified with cytological findings. Results: The AI system demonstrated superior diagnostic performance, with an overall sensitivity of 80% [95% confidence interval (CI): 59.3–93.2%] and specificity of 71.4% (95% CI: 53.7–85.4%). At Siriraj Hospital, the AI achieved a sensitivity of 90.0% (95% CI: 55.5–99.8%), specificity of 100.0% (95% CI: 69.2–100%), positive prediction value (PPV) of 100.0%, negative prediction value (NPV) of 90.9%, and an overall accuracy of 95.0%, indicating the benefits of AI’s extensive training across diverse datasets. The experienced radiologist’s sensitivity was 40.0% (95% CI: 21.1–61.3%), while the specificity was 80.0% (95% CIs: 63.6–91.6%), respectively, showing that the AI significantly outperformed the radiologist in terms of sensitivity (P=0.043) while maintaining comparable specificity. The inter-observer variability analysis indicated a moderate agreement (K=0.53) between the radiologist and the resident, contrasting with fair agreement (K=0.37/0.33) when each was compared with the AI system. Notably, 95% CIs for these diagnostic indexes highlight the AI system’s consistent performance across different settings. Conclusions: The findings advocate for the integration of AI into clinical settings to enhance the diagnostic accuracy of radiologists in assessing thyroid nodules. The AI system, designed as a supportive tool rather than a replacement, promises to revolutionize thyroid nodule diagnosis and management by providing a high level of diagnostic precision.


  • Open Access

    Explainable Automated TI-RADS Evaluation of Thyroid Nodules

    by Alisa Kunapinun, Dittapong Songsaeng, Sittaya Buathong, Matthew N. Dailey, Chadaporn Keatmanee, Mongkol Ekpanyapong

    A thyroid nodule, a common abnormal growth within the thyroid gland, is often identified through ultrasound imaging of the neck. These growths may be solid- or fluid-filled, and their treatment is influenced by factors such as size and location. The Thyroid Imaging Reporting and Data System (TI-RADS) is a classification method that categorizes thyroid nodules into risk levels based on features such as size, echogenicity, margin, shape, and calcification. It guides clinicians in deciding whether a biopsy or other further evaluation is needed. Machine learning (ML) can complement TI-RADS classification, thereby improving the detection of malignant tumors. When combined with expert rules (TI-RADS) and explanations, ML models may uncover elements that TI-RADS misses, especially when TI-RADS training data are scarce. In this paper, we present an automated system for classifying thyroid nodules according to TI-RADS and assessing malignancy effectively. We use ResNet-101 and DenseNet-201 models to classify thyroid nodules according to TI-RADS and malignancy. By analyzing the models’ last layer using the Grad-CAM algorithm, we demonstrate that these models can identify risk areas and detect nodule features relevant to the TI-RADS score. By integrating Grad-CAM results with feature probability calculations, we provide a precise heat map, visualizing specific features within the nodule and potentially assisting doctors in their assessments. Our experiments show that the utilization of ResNet-101 and DenseNet-201 models, in conjunction with Grad-CAM visualization analysis, improves TI-RADS classification accuracy by up to 10%. This enhancement, achieved through iterative analysis and re-training, underscores the potential of machine learning in advancing thyroid nodule diagnosis, offering a promising direction for further exploration and clinical application.