AMAndrew Mueller

Andrew Mueller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew Mueller has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contention-aware Performance Modeling for Heterogeneous Edge and Cloud Systems

    by Ismet Dagli, Andrew Depke, Andrew Mueller, Sahil Hassan, Ali Akoglu, Mehmet Esat Belviranli


  • Open Access

    High-speed detection of 1550 nm single photons with superconducting nanowire detectors

    by Ioana Craiciu, Boris Korzh, Andrew D. Beyer, Andrew Mueller, Jason P. Allmaras, Lautaro Narváez, Maria Spiropulu, Bruce Bumble, Thomas Lehner, Emma E. Wollman, et al.

    Superconducting nanowire single photon detectors are a key technology for quantum information and science due to their high efficiency, low timing jitter, and low dark counts. In this work, we present a detector for single 1550 nm photons with up to 78% detection efficiency, timing jitter below 50 ps FWHM, 158 counts/s dark count rate - as well as a world-leading maximum count rate of 1.5 giga-counts/s at 3 dB compression. The PEACOQ detector (Performance-Enhanced Array for Counting Optical Quanta) comprises a linear array of 32 straight superconducting niobium nitride nanowires which span the mode of an optical fiber. This design supports high count rates with minimal penalties for detection efficiency and timing jitter. We show how these trade-offs can be mitigated by implementing independent read-out for each nanowire and by using a temporal walk correction technique to reduce count-rate dependent timing jitter. These detectors make quantum communication practical on a 10 GHz clock.

  • Open Access

    Time-walk and jitter correction in SNSPDs at high count rates

    by Andrew Mueller, Emma E. Wollman, Boris Korzh, Andrew D. Beyer, Lautaro Narvaez, Ryan Rogalin, Maria Spiropulu, Matthew D. Shaw

    Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s we reduce the full width at one percent maximum level (FW1%M) by 45%. The method therefore enables certain quantum communication protocols that are rate-limited by the (FW1%M) metric to operate almost twice as fast. \c{opyright} 2022. All rights reserved.