Pablo Ángel Prieto-Díaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pablo Ángel Prieto-Díaz has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Marcos Vera
Universidad Carlos III de Madrid
7 shared publications Ange A. Maurice
3 shared publications- Ange A. Maurice
Universidad Carlos III de Madrid
3 shared publications - Andrea Trovò
University of Padua
2 shared publications Marcos Vera
2 shared publications- Massimo Guarnieri
University of Padua, Padova, Italy
2 shared publications
Latest Publications
- Open Access
- 6 February 2026
- Published by Elsevier in Advanced Sensor and Energy Materials
- Vol. 5 (1)
Low-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries
- 6 February 2026
- Published by Elsevier in Advanced Sensor and Energy Materials
- Vol. 5 (1)
Open AccessLow-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries
- Open Access
- 28 October 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 525
Electrolyte mixing in vanadium flow battery tanks: Effects on capacity utilization
- 28 October 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 525
Open AccessElectrolyte mixing in vanadium flow battery tanks: Effects on capacity utilization
- Open Access
- 5 August 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Electrolyte mixing in vanadium flow battery tanks: Effects on capacity utilization
This work investigates the fluid dynamics of electrolyte mixing within the tanks of vanadium flow batteries. Custom axisymmetric tanks are used to study the different flow regimes that emerge during battery cycling at various flow rates. A dual online diagnostic tool based on UV-vis spectroscopy enables precise tracking of the state of charge (SoC) of both electrolytes. The experimental campaign is supported by a mathematical model that implements accurate empirical fits for the density and viscosity obtained in previous work, which qualitatively reproduces the observed behavior. The results show that at high flow rates, momentum-dominated flows induce strong mixing in both tanks, yielding homogeneously mixed electrolytes. As the flow rate decreases, buoyancy effects start to play a role, and each electrolyte exhibits different flow regimes as a result of different SoC-dependent density changes. During charge, the positive tank exhibits a submerged jet that crosses the tank directly to the outlet, causing a decrease in capacity. In contrast, the negative tank shows a stratified piston flow that becomes more prevalent as the jet momentum decreases. During discharge, the negolyte flows directly to the outlet, causing a marked capacity drop, while the positive tank maintains relatively well-mixed conditions. These findings highlight the critical impact of tank-level mixing on battery performance and indicate the need for further investigations carried out under operational conditions that better represent industrial settings, with an emphasis on large-scale flow battery systems.
- 5 August 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessElectrolyte mixing in vanadium flow battery tanks: Effects on capacity utilization
This work investigates the fluid dynamics of electrolyte mixing within the tanks of vanadium flow batteries. Custom axisymmetric tanks are used to study the different flow regimes that emerge during battery cycling at various flow rates. A dual online diagnostic tool based on UV-vis spectroscopy enables precise tracking of the state of charge (SoC) of both electrolytes. The experimental campaign is supported by a mathematical model that implements accurate empirical fits for the density and viscosity obtained in previous work, which qualitatively reproduces the observed behavior. The results show that at high flow rates, momentum-dominated flows induce strong mixing in both tanks, yielding homogeneously mixed electrolytes. As the flow rate decreases, buoyancy effects start to play a role, and each electrolyte exhibits different flow regimes as a result of different SoC-dependent density changes. During charge, the positive tank exhibits a submerged jet that crosses the tank directly to the outlet, causing a decrease in capacity. In contrast, the negative tank shows a stratified piston flow that becomes more prevalent as the jet momentum decreases. During discharge, the negolyte flows directly to the outlet, causing a marked capacity drop, while the positive tank maintains relatively well-mixed conditions. These findings highlight the critical impact of tank-level mixing on battery performance and indicate the need for further investigations carried out under operational conditions that better represent industrial settings, with an emphasis on large-scale flow battery systems.
- Open Access
- 15 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Low-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries
We presents a novel, low-cost optical sensor for accurate real-time monitoring of state of charge (SoC) and total vanadium concentration in vanadium flow batteries. Using only six discrete wavelengths, the sensor achieves precision comparable to full-spectrum methods while significantly reducing equipment costs and complexity. A general deconvolution method is used to measure both the SoC and the total vanadium concentration in both the posolyte and negolyte, with calibration covering concentrations from 1.2 to 1.8 M. We achieve an overall accuracy of 2.4% for the SoC and 70 mM for the total vanadium concentration. Additionally, an optimization study is proposed to determine the optimal number and placement of spectral channels, providing a basis for designing tailored optical sensors for vanadium electrolytes.
- 15 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessLow-cost optical multi-wavelength sensor for accurate real-time state-of-charge monitoring in vanadium flow batteries
We presents a novel, low-cost optical sensor for accurate real-time monitoring of state of charge (SoC) and total vanadium concentration in vanadium flow batteries. Using only six discrete wavelengths, the sensor achieves precision comparable to full-spectrum methods while significantly reducing equipment costs and complexity. A general deconvolution method is used to measure both the SoC and the total vanadium concentration in both the posolyte and negolyte, with calibration covering concentrations from 1.2 to 1.8 M. We achieve an overall accuracy of 2.4% for the SoC and 70 mM for the total vanadium concentration. Additionally, an optimization study is proposed to determine the optimal number and placement of spectral channels, providing a basis for designing tailored optical sensors for vanadium electrolytes.
- Open Access
- 10 June 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 94
Measuring density and viscosity of vanadium electrolytes: A database with multivariate polynomial fits
- 10 June 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 94
Open AccessMeasuring density and viscosity of vanadium electrolytes: A database with multivariate polynomial fits
- Open Access
- 11 May 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 492
Experiment-supported survey of inefficient electrolyte mixing and capacity loss in vanadium flow battery tanks
- 11 May 2024
- Published by Elsevier in Chemical Engineering Journal
- Vol. 492
Open AccessExperiment-supported survey of inefficient electrolyte mixing and capacity loss in vanadium flow battery tanks
- Open Access
Early Investigations on Electrolyte Mixing Issues in Large Flow Battery Tanks
Most investigations on flow batteries (FBs) make the assumption of perfectly mixed electrolytes inside the tanks without estimating their likelihood, while specific analyses are missing in the literature. This paper presents a pioneering investigation of the electrolyte flow dynamics inside FB tanks. This study considers the Open Circuit Voltage (OCV) measured at the stack of a 9 kW/27 kWh Vanadium FB with 500 L tanks. Order-of-magnitude estimates of the measured dynamics suggest that differences in densities and viscosities of the active species drive gradients of concentrations with different patterns in the positive and negative tanks and in charge and discharge, affected by current and flow rate, which result in significant deviation from homogeneity, affecting the State of Charge (SoC) of the electrolytes flowed into the stack and thus the FB performance. In particular, stratifications of the inlet electrolytes may appear which are responsible for delays in reaching the outlets, with initial plateau and following step (s) in the SoC at the stack. These events can have a major impact in the performance of industrial FBs with large tanks and suggest that specific tank designs may improve the overall dynamics, calling for further analysis.
Open AccessEarly Investigations on Electrolyte Mixing Issues in Large Flow Battery Tanks
Most investigations on flow batteries (FBs) make the assumption of perfectly mixed electrolytes inside the tanks without estimating their likelihood, while specific analyses are missing in the literature. This paper presents a pioneering investigation of the electrolyte flow dynamics inside FB tanks. This study considers the Open Circuit Voltage (OCV) measured at the stack of a 9 kW/27 kWh Vanadium FB with 500 L tanks. Order-of-magnitude estimates of the measured dynamics suggest that differences in densities and viscosities of the active species drive gradients of concentrations with different patterns in the positive and negative tanks and in charge and discharge, affected by current and flow rate, which result in significant deviation from homogeneity, affecting the State of Charge (SoC) of the electrolytes flowed into the stack and thus the FB performance. In particular, stratifications of the inlet electrolytes may appear which are responsible for delays in reaching the outlets, with initial plateau and following step (s) in the SoC at the stack. These events can have a major impact in the performance of industrial FBs with large tanks and suggest that specific tank designs may improve the overall dynamics, calling for further analysis.
- Open Access
- 21 March 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Measuring density and viscosity of vanadium electrolytes: An exhaustive database with multivariate polynomial fits
The variation of the physical properties of vanadium electrolytes during vanadium redox flow batteries (VRFB) operation is known to have a significant impact on the flow of the electrolytes both in the cells and in the tanks. This study presents extensive accurate measurements of the density and viscosity of vanadium electrolytes for VRFBs spanning a four-dimensional parameter space, including State of Charge (SoC), total vanadium concentration, total sulfate concentration, and temperature. The experimental results reveal different trends in the density variations of the posolyte and negolyte. Specifically, while the density of the posolyte slightly increases with SoC, that of the negolyte decreases more significantly. Furthermore, temperature exerts a linear influence on the density of both electrolytes. The analysis also reveals complex and non-linear dependencies between viscosity and the parameters under study, with more pronounced variations being observed at higher vanadium concentrations. In particular, the viscosities of both electrolytes are seen to decrease with SoC, the viscosity of the negolyte being consistently higher than that of the posolyte. We also present multivariate regression fits accurately capturing the variations of electrolyte properties, aiming to provide valuable insights into the dynamic behavior of vanadium electrolytes and enable more accurate physics-based mathematical models.
- 21 March 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessMeasuring density and viscosity of vanadium electrolytes: An exhaustive database with multivariate polynomial fits
The variation of the physical properties of vanadium electrolytes during vanadium redox flow batteries (VRFB) operation is known to have a significant impact on the flow of the electrolytes both in the cells and in the tanks. This study presents extensive accurate measurements of the density and viscosity of vanadium electrolytes for VRFBs spanning a four-dimensional parameter space, including State of Charge (SoC), total vanadium concentration, total sulfate concentration, and temperature. The experimental results reveal different trends in the density variations of the posolyte and negolyte. Specifically, while the density of the posolyte slightly increases with SoC, that of the negolyte decreases more significantly. Furthermore, temperature exerts a linear influence on the density of both electrolytes. The analysis also reveals complex and non-linear dependencies between viscosity and the parameters under study, with more pronounced variations being observed at higher vanadium concentrations. In particular, the viscosities of both electrolytes are seen to decrease with SoC, the viscosity of the negolyte being consistently higher than that of the posolyte. We also present multivariate regression fits accurately capturing the variations of electrolyte properties, aiming to provide valuable insights into the dynamic behavior of vanadium electrolytes and enable more accurate physics-based mathematical models.
- Open Access
Fluid dynamics of mixing in the tanks of small vanadium redox flow batteries: Insights from order-of-magnitude estimates and transient two-dimensional simulations
This paper investigates the fluid dynamics of mixing in the tanks of small-scale vanadium redox flow batteries. These systems use two redox pairs dissolved in separate electrolytes to convert electrical energy into chemical energy, a process that can be reversed in an efficient way to restore the initial electrical energy with negligible chemical losses. After flowing through the electrochemical cell, the electrolytes are stored in separate tanks, where they discharge as submerged jets with small temperature and composition changes compared to the electrolyte already present in the tanks. The subsequent mixing process is critical for battery performance, as imperfect mixing tends to reduce the energy capacity and may lead to asymmetric battery operation. The analysis starts using order-of-magnitude estimates to determine the conditions under which the mixing process is dominated by momentum or buoyancy. Transient two-dimensional simulations illustrate the different flow regimes that emerge in the tanks under laminar flow conditions. The results show that, contrary to the common assumption, the electrolytes do not mix well in the tanks. In the presence of high-momentum -- and, specially, positively buoyant -- jets, a significant fraction of the electrolyte remains unmixed and unreacted for long periods, thus reducing the energy capacity. The results also show that the availability of reliable electrolyte properties is crucial for the accuracy of the numerical simulations, as, under the mixed convection conditions that typically prevail in vanadium redox flow batteries, small density variations can significantly impact the long-term mixing of the electrolytes. In particular, in momentum-dominated flows the cumulative effect of density changes over time eventually leads to flow instabilities that significantly promote mixing; therefore, they should be taken into account in future studies.
Open AccessFluid dynamics of mixing in the tanks of small vanadium redox flow batteries: Insights from order-of-magnitude estimates and transient two-dimensional simulations
This paper investigates the fluid dynamics of mixing in the tanks of small-scale vanadium redox flow batteries. These systems use two redox pairs dissolved in separate electrolytes to convert electrical energy into chemical energy, a process that can be reversed in an efficient way to restore the initial electrical energy with negligible chemical losses. After flowing through the electrochemical cell, the electrolytes are stored in separate tanks, where they discharge as submerged jets with small temperature and composition changes compared to the electrolyte already present in the tanks. The subsequent mixing process is critical for battery performance, as imperfect mixing tends to reduce the energy capacity and may lead to asymmetric battery operation. The analysis starts using order-of-magnitude estimates to determine the conditions under which the mixing process is dominated by momentum or buoyancy. Transient two-dimensional simulations illustrate the different flow regimes that emerge in the tanks under laminar flow conditions. The results show that, contrary to the common assumption, the electrolytes do not mix well in the tanks. In the presence of high-momentum -- and, specially, positively buoyant -- jets, a significant fraction of the electrolyte remains unmixed and unreacted for long periods, thus reducing the energy capacity. The results also show that the availability of reliable electrolyte properties is crucial for the accuracy of the numerical simulations, as, under the mixed convection conditions that typically prevail in vanadium redox flow batteries, small density variations can significantly impact the long-term mixing of the electrolytes. In particular, in momentum-dominated flows the cumulative effect of density changes over time eventually leads to flow instabilities that significantly promote mixing; therefore, they should be taken into account in future studies.