AOAna Claudia Tonelli de Oliveira

Ana Claudia Tonelli de Oliveira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ana Claudia Tonelli de Oliveira has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Semi-supervised Ensemble Learning for Automatic Interpretation of Lung Ultrasound Videos

    by Bárbara Malainho, João Freitas, Catarina Rodrigues, Ana Claudia Tonelli, André Santanchè, Marco A. Carvalho-Filho, Jaime C. Fonseca, Sandro Queirós

    Point-of-care ultrasound (POCUS) stands as a safe, portable, and cost-effective imaging modality for swift bedside patient examinations. Specifically, lung ultrasonography (LUS) has proven useful in evaluating both acute and chronic pulmonary conditions. Despite its clinical value, automatic LUS interpretation remains relatively unexplored, particularly in multi-label contexts. This work proposes a novel deep learning (DL) framework tailored for interpreting lung POCUS videos, whose outputs are the finding(s) present in these videos (such as A-lines, B-lines, or consolidations). The pipeline, based on a residual (2+1)D architecture, initiates with a pre-processing routine for video masking and standardisation, and employs a semi-supervised approach to harness available unlabeled data. Additionally, we introduce an ensemble modeling strategy that aggregates outputs from models trained to predict distinct label sets, thereby leveraging the hierarchical nature of LUS findings. The proposed framework and its building blocks were evaluated through extensive experiments with both multi-class and multi-label models, highlighting its versatility. In a held-out test set, the categorical proposal, suited for expedite triage, achieved an average F1-score of 92.4%, while the multi-label proposal, helpful for patient management and referral, achieved an average F1-score of 70.5% across five relevant LUS findings. Overall, the semi-supervised methodology contributed significantly to improved performance, while the proposed hierarchy-aware ensemble provided moderate additional gains.


  • Prognostic value of Doppler waveform analysis of common femoral vein in septic patients: a prospective cohort study

    by Nathalia Helbig Dias, Douglas Rodrigues Gomes, Ana Claudia Tonelli de Oliveira, José Augusto Santos Pellegrini, Márcio Manozzo Boniatti

    Objectives To assess whether there is an association between abnormal common femoral vein (CFV) Doppler waveform and intensive care unit (ICU) mortality in patients with sepsis. Methods Patients admitted to the ICU with sepsis were included. Pulsed-wave Doppler was performed by examining the CFV in the short axis without angle correction and in the long axis with angle correction. An abnormal CFV Doppler waveform was determined by a retrograde velocity peak (RVP) > 10 cm/s in the long axis or RVP > 50% of the antegrade velocity peak in the short axis. TAPSE < 17 mm was defined as right ventricular (RV) dysfunction. The primary outcome was ICU mortality. Results One hundred and ten patients were included. There was no association between abnormal CFV Doppler waveforms in the long (p = 0.709) and short axes (p = 0.171) and ICU mortality. TAPSE measurements were performed in 16 patients. RV dysfunction was identified in 8 (50.0%) patients. There was no association between the diagnosis of RV dysfunction based on TAPSE measurement and the identification of abnormal CFV Doppler waveforms in the long axis (p = 1.000) and in the short axis (p = 1.000). Conclusion Abnormal CFV Doppler waveforms were not associated with ICU mortality in patients with sepsis. Furthermore, in the exploratory analysis, these alterations were not useful in identifying RV dysfunction in these patients. Graphical abstract